Schneider Electric
9038AW1N5
1 / 1
Descripción
Activo maduro
This product is part of the NEMA Pressure Switches range, an offer of mechanical alternators. This mechanical alternator has 4 normally closed, snap action, DPST-DB (double pole single throw, double break) form YY contacts. The open tank mechanical alternator supports pedestal mounting method and vertical float rod angle for operating in any position. It is furnished with screw clamp terminals for electrical connection and 2 conduit entries for 3/4-14 NPT. Offers electrical durability of 100 cycles and mechanical durability of 300 cycles. The enclosure is made of cast aluminum. It is a NEMA 4 rated product. This product is certified by UL, CSA, CE. Meets UL 508 standards. When liquid level rises to the first level, one pump turns on. Both pumps automatically turn on when a peak condition occurs and the liquid level continues to rise. If form N5 or N25 is present and the water level continues to rise. Mechanical alternator provides a simple, positive means of mechanically alternating two pumps or motors. This alternator is used on devices that are installed in a duplex system with a common tank. It is a NEMA 4 rated product. This product is certified by CE, CSA and UL. Meets UL 508 standards. When liquid level rises to the first level, one pump turns on. Both pumps automatically turn on when a peak condition occurs and the liquid level continues to rise. If form N5 or N25 is present and the water level continues to rise. Mechanical alternator provides a simple, positive means of mechanically alternating two pumps or motors. This alternator is used on devices that are installed in a duplex system with a common tank.- Country of Origin
- MX
- Part Number
- 9038AW1N5
- Tariff Code
- 8536509065
- EAN
- 39122219
- UPC
- 785901173908
- UNSPSC
- 39122219
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
1
Formas de pago:
Specifications
- Range Of Product
- Square D Pumptrol
- Product Specific Application
- mechanically alternating the operation of two pumps or motors
- Quantity Per Set
- set of 1
- Electrical Circuit Type
- power circuit with control duty alarm
- Product Or Component Type
- mechanical alternator
- Type Of Packing
- individual
- Device Application
- open tank
- Device Short Name
- 9038A
Contractual warranty
- Warranty
- 18 months
Complementary
- Cable Entry Number
- 2 conduit entries for 3/4"-14 NPT UL 508
- Electrical Connection
- screw-clamp terminals 10 AWG
- Contact Operation
- contacts close on liquid rise
- Product Destination
- for open tank
- Terminal Block Type
- 8 terminals
- Terminals Description Iso N°1
- line-load-load-line
- [Ui] Rated Insulation Voltage
- 575 V UL 508
- Short-Circuit Protection
- 20 A cartridge fuse gG
- Controlled Fluid
- fresh water specific gravity of 0.85 in or higher || sea water specific gravity of 0.85 in or higher || hydraulic oil specific gravity of 0.85 in or higher || corrosive fluid specific gravity of 0.85 in or higher
- Device Mounting
- pedestal
- Mechanical Durability
- 300 cycles
- Float Rod Angle
- vertical
- Factory Modification
- addition of a third, high-water alarm circuit (SPST-NO-DB)
- Float Movement
- variable adjustable
- Operating Position
- vertical position only
- Enclosure Material
- Cast Aluminium
- Maximum Operating Rate
- 60 cyc/mn
- Local Signalling
- without
- Contacts Type And Composition
- 4 NC, snap action, DPST-DB, Form YY
- Motor Power Kw
- 1.5 kW 2 hp)115 V AC, 1 phase || 2.2 kW 3 hp)115 V AC, 3 phase || 2.2 kW 3 hp)230 V AC, 1 phase || 3.7 kW 5 hp)230 V AC, 3 phase || 0.75 kW 1 hp)460 V AC, 3 phase || 0.75 kW 1 hp)475 V AC, 3 phase || 0.18 kW 0.25 hp)32 V DC || 0.37 kW 0.5 hp)115 V DC || 0.37 kW 0.5 hp)230 V DC
- Float Position
- any
- Kit Composition
- float switch || rod and float are to be choosen in accessories
- Electrical Durability
- 100 cycles 60 cyc/mn
Offer Sustainability
- Circularity Profile
- ENVEOLI111210EN
- Environmental Disclosure
- ENVPEP111211EN
- Eu Rohs Directive
- Not applicable, out of EU RoHS legal scope
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Environment
- Product Certifications
- UL listed file E12158 || CSA file LR25490
- Ambient Air Temperature For Operation
- -22-220 °F
- Ambient Air Temperature For Storage
- -22-220 °F
- Standards
- CE || UL 508
- Nema Degree Of Protection
- NEMA 4 UL 50
Documentos
Data Sheet
DescargarOtras categorías
ActuadoresBloquesCables, tuberías y manguerasCompresoresControlAcoplamientos y AccesoriosCilindros y PistonesElectrónicaFiltrosHVACPCs industriales y HMIsIluminaciónTécnica linealMotoresFuente de alimentaciónTransmisión de energíaBombas y VálvulasEnergías renovablesRobóticaSellos, anillos y conectoresSensores y dispositivos de mediciónHerramientas y AccesoriosCNCOtros