Schneider Electric
ATV930D11Y6
1 / 1
Descripción
Activo maduro
- Country of Origin
- IN
- Part Number
- ATV930D11Y6
- Tariff Code
- 85044095
- EAN
- 3606481325297
- UNSPSC
- 39122001
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
1
Formas de pago:
Offer Sustainability
- Mercury Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Upgradeability
- Upgraded components available
- Rohs Exemption Information
- Yes
- Environmental Disclosure
- ENVPEP1704001EN
- Sustainable Offer Status
- Green Premium product
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Circularity Profile
- ENVEOLI1704001EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Complementary
- Discrete Input Logic
- positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
- Power Dissipation In W
- forced convection 198 W 500 V 4 kHz || natural convection 98 W 500 V 4 kHz
- Analogue Output Type
- software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
- Discrete Output Type
- logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
- Maximum Switching Current
- relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC || relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC || relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
- 4 Quadrant Operation Possible
- true
- Exchange Mode
- half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
- Local Signalling
- local diagnostic 3 LED mono/dual colour) || presence of voltage 1 LED red) || embedded communication status 3 LED dual colour) || communication module status 4 LED dual colour)
- Data Format
- 8 bits, configurable odd, even or no parity Modbus serial
- Relative Symmetric Network Frequency Tolerance
- 5 %
- Net Weight
- 22 kg
- Type Of Polarization
- no impedance
- Relay Output Type
- configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
- Analogue Input Number
- 3
- Motor Slip Compensation
- not available in permanent magnet motor law || automatic whatever the load || can be suppressed || adjustable
- Discrete Output Number
- 2
- Transmission Rate
- 10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
- Method Of Access
- slave Modbus TCP
- Number Of Addresses
- 1-247
- Discrete Input Number
- 10
- Linearity Error
- AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
- Number Of Addresses
- 1-247 Modbus serial
- With Safety Function Safe Stop 1 (Ss1)
- true
- Width
- 246 mm
- Transmission Rate
- 10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
- Depth
- 242 mm
- Analogue Input Type
- AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
- Sampling Duration
- 2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
- Electrical Connection
- control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || DC bus screw terminal 4...10 mm² AWG 12...AWG 8 || line side screw terminal 4...10 mm² AWG 12...AWG 8 || motor screw terminal 4...10 mm² AWG 12...AWG 8
- With Safety Function Safe Brake Management (Sbc/Sbt)
- true
- Height
- 420 mm
- Acceleration And Deceleration Ramps
- linear adjustable separately from 0.01...9999 s || S, U or customized
- Maximum Output Voltage
- 690.0 V
- Base Load Current At High Overload
- 9.5 A
- Transmission Frame
- RTU
- Relay Output Number
- 3
- With Safety Function Safe Torque Off (Sto)
- true
- Data Format
- 8 bits, configurable odd, even or no parity
- Base Load Current At Low Overload
- 13.5 A
- Accuracy
- +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
- Input Compatibility
- DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
- Connector Type
- 2 RJ45 || 1 RJ45
- Analogue Output Number
- 2
- Physical Interface
- Ethernet || 2-wire RS 485
- Minimum Switching Current
- relay output R1, R2, R3 5 mA 24 V DC
- Refresh Time
- relay output R1, R2, R3)5 ms +/- 0.5 ms)
- Isolation
- between power and control terminals
- Brake Chopper Integrated
- true
- Quantity Per Set
- 1
- Type Of Polarization
- no impedance Modbus serial
- Braking To Standstill
- by DC injection
- Discrete Input Type
- DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
- Protection Type
- thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || motor phase break drive || overvoltages on the DC bus drive || line supply overvoltage drive || line supply undervoltage drive || line supply phase loss drive || overspeed drive || break on the control circuit drive
- Supply
- external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection
- With Safety Function Safely Limited Speed (Sls)
- true
Specifications
- Prospective Line Isc
- 70 kA
- Network Frequency
- 50-60 Hz
- Product Destination
- asynchronous motors || synchronous motors
- Line Current
- 13.6 A 500 V normal duty) || 10.4 A 500 V heavy duty) || 14.7 A 690 V normal duty) || 10.5 A 690 V heavy duty)
- Phase
- 3 phase
- Asynchronous Motor Control Profile
- optimized torque mode || constant torque standard || variable torque standard
- Variant
- standard version || with braking chopper
- Product Or Component Type
- variable speed drive
- Apparent Power
- 17.6 kVA 690 V normal duty) || 12.5 kVA 690 V heavy duty)
- Ip Degree Of Protection
- IP21
- Switching Frequency
- 2...8 kHz adjustable || 4...8 kHz with derating factor
- Maximum Transient Current
- 16.2 A 60 s normal duty) || 14.3 A 60 s heavy duty)
- Communication Port Protocol
- Modbus TCP || EtherNet/IP || Modbus serial
- Product Specific Application
- process for industrial
- Option Card
- slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module CANopen SUB-D 9 || slot A communication module CANopen screw terminals || slot A/slot B/slot C digital and analog I/O extension module || slot A/slot B/slot C output relay extension module || slot B 5/12 V digital encoder interface module || slot B analog encoder interface module || slot B resolver encoder interface module || communication module Ethernet Powerlink
- Degree Of Protection
- UL type 1
- Maximum Output Frequency
- 599 Hz
- Range Of Product
- Altivar Process ATV900
- Motor Power Kw
- 7.5 kW normal duty || 5.5 kW heavy duty
- [Us] Rated Supply Voltage
- 500...690 V - 15...10 %
- Mounting Mode
- wall mount
- Discrete Input Logic
- 16 preset speeds
- Continuous Output Current
- 13.5 A 4 kHz normal duty || 9.5 A 4 kHz heavy duty
- Nominal Switching Frequency
- 4 kHz
- Emc Filter
- integrated || with EMC plate option
- Device Application
- Industrial Application
- Synchronous Motor Control Profile
- permanent magnet motor || synchronous reluctance motor
Environment
- Product Certifications
- TÜV || UL || CSA
- Maximum Deflection Under Vibratory Load (During Operation)
- 1.5 mm at 2...13 Hz
- Standards
- UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
- Insulation Resistance
- > 1 MOhm 500 V DC for 1 minute to earth
- Shock Resistance
- 15 gn 11 ms IEC 60068-2-27
- Environmental Characteristic
- chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
- Vibration Resistance
- 1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
- Noise Level
- 58 dB 86/188/EEC
- Regulation Loop
- adjustable PID regulator
- Permitted Relative Humidity (During Operation)
- class 3K5 according to EN 60721-3
- Operating Altitude
- <= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
- Overvoltage Category
- III
- Environmental Class (During Operation)
- class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
- Maximum Acceleration Under Shock Impact (During Operation)
- 150 m/s² at 11 ms
- Pollution Degree
- 2
- Electromagnetic Compatibility
- electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6
- Ambient Air Temperature For Operation
- -15-50 °C without derating) || 50-60 °C with derating factor)
- Volume Of Cooling Air
- 330 m3/h
- Marking
- CE
- Maximum Acceleration Under Vibrational Stress (During Operation)
- 10 m/s² at 13...200 Hz
- Noise Level
- 58 dB
- Ambient Air Temperature For Storage
- -40-70 °C
- Relative Humidity
- 5-95 % without condensation IEC 60068-2-3
- Assembly Style
- enclosed
- Operating Position
- vertical +/- 10 degree
- Ambient Air Transport Temperature
- -40-70 °C