IEC contactor,Easy TeSys DPE,nonreversing,18A,3P,7.5HP at 480V AC,24V DC coil
DPE18BL
DPE18BL
DPE18BL
DPE18BL
DPE18BL
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:
Oferta con plazo de entrega del fabricante
Entrega:1 - 2 días laborables
El mejor precio:
Enviar solicitud de precio

Additional Information

Part Number
DPE18BL
UNSPSC
39121529
Tariff Code
8536410045
Country of Origin
ID

Complementary

Non-Overlap Time
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Minimum Switching Current
5 mA for signalling circuit
[Ue] Rated Operational Voltage
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Height
77 mm
Power Dissipation Per Pole
0.36 W AC-3 || 1.56 W AC-1
Average Impedance
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Control Circuit Voltage Limits
drop-out: 0.1...0.3 Uc (at <70 °C) || operational: 0.8...1.25 Uc (at <60 °C) || operational: 1...1.25 Uc (at <70 °C)
[Ith] Conventional Free Air Thermal Current
10 A (at 60 °C) for signalling circuit || 25 A (at 60 °C) for power circuit
Mounting Support
rail || plate
Control Circuit Type
DC
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Hold-In Power Consumption In W
2.4-2.4 W 20 °C
Insulation Resistance
> 10 MOhm for signalling circuit
Rated Breaking Capacity
250 A at 440 V for power circuit conforming to IEC 60947
Irms Rated Making Capacity
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
Net Weight
0.325 kg
Connections - Terminals
power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
Coil Technology
without built-in suppressor module
Minimum Switching Voltage
17 V for signalling circuit
Maximum Operating Rate
3600 cyc/h 60 °C
Signalling Circuit Frequency
25...400 Hz
Tightening Torque
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2
Electrical Durability
1 Mcycles 18 A AC-3 <= 440 V || 0.6 Mcycles 25 A AC-1 <= 440 V
Mechanical Durability
10 Mcycles
Inrush Power In W
2.4-2.4 W 20 °C)
Auxiliary Contacts Type
mechanically linked 1 NO IEC 60947-5-1
Operating Time
65.45...88.55 ms closing || 20...30 ms opening
Width
45 mm
Depth
86 mm
Heat Dissipation
2-3 W 50/60 Hz

Environment

Product Certifications
UL || CSA
Ambient Air Temperature For Operation
-40-60 °C
Standards
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 60947-4-1
Pollution Degree
3
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947
Ambient Air Temperature For Storage
-60-80 °C
Ip Degree Of Protection
IP20 front face IEC 60529
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Operating Altitude
0...6561.68 ft (0...2000 m)
Fire Resistance
850 °C IEC 60695-2-1
Overvoltage Category
III
[Ui] Rated Insulation Voltage
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1

Specifications

[Uc] Control Circuit Voltage
24 V DC
Auxiliary Contact Composition
1 NO
Contactor Application
resistive load || motor control
Product Or Component Type
contactor
Product Name
Easy TeSys DPE
Range
Easy TeSys
Pole Contact Composition
3 NO
Utilisation Category
AC-4 || AC-1 || AC-3
[Ie] Rated Operational Current
18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Poles Description
3P
Maximum Horse Power Rating
0.5 hp at 115 V AC 50/60 Hz for 1 phase motors || 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 3 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 3 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 7.5 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 10 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Motor Power Kw
4 kW 220...230 V AC 50/60 Hz || 7.5 kW 380...400 V AC 50/60 Hz || 9 kW 415 V AC 50/60 Hz || 9 kW 440 V AC 50/60 Hz || 10 kW 500 V AC 50/60 Hz || 10 kW 660...690 V AC 50/60 Hz
Device Short Name
DPE

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110230EN
Sustainable Offer Status
Green Premium product
Toxic Heavy Metal Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI1102030EN
Eu Rohs Directive
Compliant with Exemptions

Documentos

Data Sheet

Descargar

Modelos CAD

Rastrear piezas
Rastrear piezas
Descargar

Productos relacionados