Schneider Electric
DPE32BL
1 / 5
Descripción
Activo maduro
Easy TeSys DPE IEC contactor, 3 poles (3NO), for motor control applications up to 32A/690V AC-3 (15 HP@480V). It provides a 24V DC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh).- Country of Origin
- ID
- Part Number
- DPE32BL
- Tariff Code
- 85364190
- EAN
- 3606481064295
- UNSPSC
- 39121529
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
1
Formas de pago:
Specifications
- [Uc] Control Circuit Voltage
- 24 V DC
- Auxiliary Contact Composition
- 1 NO
- Contactor Application
- resistive load || motor control
- Product Or Component Type
- contactor
- Product Name
- Easy TeSys DPE
- Range
- Easy TeSys
- Pole Contact Composition
- 3 NO
- Utilisation Category
- AC-4 || AC-1 || AC-3
- [Ie] Rated Operational Current
- 32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
- Poles Description
- 3P
- Maximum Horse Power Rating
- 2 hp at 115 V AC 50/60 Hz for 1 phase motors || 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors
- Motor Power Kw
- 7.5 kW 220...230 V AC 50/60 Hz || 15 kW 380...400 V AC 50/60 Hz || 15 kW 415 V AC 50/60 Hz || 15 kW 440 V AC 50/60 Hz || 18.5 kW 500 V AC 50/60 Hz || 18.5 kW 660...690 V AC 50/60 Hz
- Device Short Name
- DPE
Complementary
- Non-Overlap Time
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Minimum Switching Current
- 5 mA for signalling circuit
- [Ue] Rated Operational Voltage
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Height
- 85 mm
- Power Dissipation Per Pole
- 3.2 W AC-1 || 1.25 W AC-3
- Average Impedance
- 2 mOhm - Ith 40 A 50 Hz for power circuit
- Control Circuit Voltage Limits
- drop-out: 0.1...0.3 Uc (at <70 °C) || operational: 0.8...1.25 Uc (at <60 °C) || operational: 1...1.25 Uc (at <70 °C)
- [Ith] Conventional Free Air Thermal Current
- 10 A (at 60 °C) for signalling circuit || 50 A (at 60 °C) for power circuit
- Mounting Support
- rail || plate
- Control Circuit Type
- DC
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Hold-In Power Consumption In W
- 2.4-2.4 W 20 °C
- Insulation Resistance
- > 10 MOhm for signalling circuit
- Rated Breaking Capacity
- 450 A at 440 V for power circuit conforming to IEC 60947
- Irms Rated Making Capacity
- 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
- Associated Fuse Rating
- 10 A gG for signalling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
- Net Weight
- 0.37 kg
- Connections - Terminals
- power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
- Coil Technology
- without built-in suppressor module
- Minimum Switching Voltage
- 17 V for signalling circuit
- Maximum Operating Rate
- 3600 cyc/h 60 °C
- Signalling Circuit Frequency
- 25...400 Hz
- Tightening Torque
- power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2
- Electrical Durability
- 1 Mcycles 32 A AC-3 <= 440 V || 0.6 Mcycles 40 A AC-1 <= 440 V
- Mechanical Durability
- 10 Mcycles
- Inrush Power In W
- 2.4-2.4 W 20 °C)
- Auxiliary Contacts Type
- mechanically linked 1 NO IEC 60947-5-1
- Operating Time
- 65.45...88.55 ms closing || 20...30 ms opening
- Width
- 45 mm
- Depth
- 92 mm
- Heat Dissipation
- 2-3 W 50/60 Hz
Environment
- Product Certifications
- UL || CSA
- Ambient Air Temperature For Operation
- -40-60 °C
- Standards
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 60947-4-1
- Pollution Degree
- 3
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60947
- Ambient Air Temperature For Storage
- -60-80 °C
- Ip Degree Of Protection
- IP20 front face IEC 60529
- Mechanical Robustness
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
- Operating Altitude
- 0...6561.68 ft (0...2000 m)
- Fire Resistance
- 850 °C IEC 60695-2-1
- Overvoltage Category
- III
- [Ui] Rated Insulation Voltage
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP110230EN
- Sustainable Offer Status
- Green Premium product
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile
- ENVEOLI1102030EN
- Eu Rohs Directive
- Compliant with Exemptions
Modelos CAD
traceparts
DescargarOtras categorías
ActuadoresBloquesCables, tuberías y manguerasCompresoresControlAcoplamientos y AccesoriosCilindros y PistonesElectrónicaFiltrosHVACPCs industriales y HMIsIluminaciónTécnica linealMotoresFuente de alimentaciónTransmisión de energíaBombas y VálvulasEnergías renovablesRobóticaSellos, anillos y conectoresSensores y dispositivos de mediciónHerramientas y AccesoriosCNCOtros