1 / 1
thumbnail

Descripción

Activo maduro
LC2D150M7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 150A AC-3 75kW@400V, it includes a 220V 50/60Hz AC coil, 2NO+2NC aux contacts, mechanical and electrical interlock. LC2D150M7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 75kW@400V. It includes a 220V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical and electrical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 266mm wide, for DIN-rail and panel mounting. Assembled with mechanical and electrical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 220V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 0.8 million cycles at 150A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.
Country of Origin
CZ
Part Number
LC2D150M7
Tariff Code
85364900
EAN
3389110509083
UNSPSC
39121529
Métodos de pago:
Mejor oferta de:
DEProveedor de confianza de Automa.Net
Disponibilidad:
1 pieza
En stock
Actualizado en: 31-10-2024
Garantía:
12 meses
Entrega Estimada:
Bajo pedido
Condición:
Nuevos excedentes
Nuevos excedentes - Un artículo nuevo, sin usar, sin daños y sin garantía del fabricante. El artículo puede venir sin embalaje original o en embalaje de reemplazo. Si se proporciona, es posible que la caja haya sido abierta.
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía

Environment

Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open6 Gn for 11 ms
Ambient Air Temperature For Operation
-40-60 °C || 60-70 °C with derating
Height
158 mm
Climatic Withstand
IACS E10
Pollution Degree
3
Net Weight
6.4 kg
Flame Retardance
V1 conforming to UL 94
Ambient Air Temperature For Storage
-60-80 °C
Protective Treatment
TH IEC 60068-2-30
Ip Degree Of Protection
IP20 front face IEC 60529
Operating Altitude
0...9842.52 ft (0...3000 m)
Fire Resistance
850 °C IEC 60695-2-1
Width
266 mm
Depth
148 mm

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP060301EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI100405
Eu Rohs Directive
Compliant with Exemptions

Complementary

Non-Overlap Time
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Minimum Switching Current
5 mA for signalling circuit
Control Circuit Voltage Limits
0.3...0.5 Uc 55-55 °C drop-out AC 50/60 Hz || 0.8...1.15 Uc 55-55 °C operational AC 50/60 Hz
Insulation Resistance
> 10 MOhm for signalling circuit
Inrush Power In Va
280-350 VA 60 Hz 0.9 20 °C) || 280-350 VA 50 Hz 0.9 20 °C)
Coil Technology
built-in bidirectional peak limiting diode suppressor
Minimum Switching Voltage
17 V for signalling circuit
Signalling Circuit Frequency
25...400 Hz
Heat Dissipation
3-4.5 W 50/60 Hz
Auxiliary Contacts Type
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Hold-In Power Consumption In Va
2-18 VA 20 °C) 0.9 60 Hz || 2-18 VA 20 °C) 0.9 50 Hz

Specifications

Interlocking Type
electrical || mechanical
[Uc] Control Circuit Voltage
220 V AC 50/60 Hz
[Ue] Rated Operational Voltage
power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
Power Dissipation Per Pole
24 W AC-1 || 13.5 W AC-3 || 13.5 W AC-3e
Average Impedance
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Auxiliary Contact Composition
1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current
200 A (at 60 °C) for power circuit
Mounting Support
rail || plate
Control Circuit Type
AC 50/60 Hz
Standards
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application
motor control || resistive load
Rated Breaking Capacity
1400 A at 440 V for power circuit conforming to IEC 60947
Product Or Component Type
reversing contactor
Product Certifications
BV || CCC || CSA || DNV || GL || RINA || UL || EAC || UKCA
Irms Rated Making Capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 1660 A at 440 V for power circuit conforming to IEC 60947
Product Name
TeSys Deca
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1 || 315 A gG at <= 690 V coordination type 1 for power circuit || 250 A gG at <= 690 V coordination type 2 for power circuit
[Uimp] Rated Impulse Withstand Voltage
8 kV IEC 60947
Connections - Terminals
control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-2.5 mm²flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible without cable end || control circuit screw clamp terminals 1 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-2.5 mm²solid without cable end || control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end || power circuit connector 1 10-120 mm²flexible without cable end || power circuit connector 2 10-50 mm²flexible without cable end || power circuit connector 1 10-120 mm²flexible with cable end || power circuit connector 2 10-50 mm²flexible with cable end || power circuit connector 1 10-120 mm²solid without cable end || power circuit connector 2 10-50 mm²solid without cable end
Range
TeSys
Pole Contact Composition
3 NO
Device Presentation
preassembled with reversing power busbar
Utilisation Category
AC-3 || AC-1 || AC-3e
Operating Time
20...35 ms closing || 40...75 ms opening
[Ie] Rated Operational Current
200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 150 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Maximum Operating Rate
1200 cyc/h 60 °C
Electrical Durability
0.85 Mcycles 150 A AC-3 <= 440 V || 1 Mcycles 200 A AC-1 <= 440 V || 0.85 Mcycles 150 A AC-3e <= 440 V
Tightening Torque
control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Poles Description
3P
Overvoltage Category
III
Motor Power Kw
40 kW at 220...230 V AC 50 Hz || 75 kW at 380...400 V AC 50 Hz || 80 kW at 415...440 V AC 50 Hz || 90 kW at 500 V AC 50 Hz || 100 kW at 660...690 V AC 50 Hz || 75 kW at 1000 V AC 50 Hz
Maximum Horse Power Rating
40 hp at 200/208 V AC 60 Hz for 3 phase motors || 50 hp at 230/240 V AC 60 Hz for 3 phase motors || 100 hp at 460/480 V AC 60 Hz for 3 phase motors || 125 hp at 575/600 V AC 60 Hz for 3 phase motors
[Ui] Rated Insulation Voltage
power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL || power circuit 1000 V IEC 60947-4-1
Mechanical Durability
8000000 cycles
Device Short Name
LC2D
[Icw] Rated Short-Time Withstand Current
250 A 40 °C - 10 min for power circuit || 580 A 40 °C - 1 min for power circuit || 1200 A 40 °C - 10 s for power circuit || 1400 A 40 °C - 1 s for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit
Protective Cover
with