1 / 1
thumbnail

Descripción

Activo maduro
This Multi9 C60SP is a low voltage miniature circuit breaker (MCB). It is a 4P circuit breaker with 4 protected poles, 8A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 8 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 72mm x (H) 81mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
Country of Origin
FR
Part Number
M9F23408
Tariff Code
85362010
EAN
3606481169303
UNSPSC
39121633
Métodos de pago:
Mejor oferta de:
NLProveedor de confianza de Automa.Net
Disponibilidad:
1 pieza
En stock
Actualizado en: 09-11-2024
Garantía:
1 mes
Entrega Estimada:
Bajo pedido
Condición:
Nuevo Precintado de Fábrica
Nuevo Precintado de Fábrica - Un artículo completamente nuevo, sin usar, sin abrir, sin daños, en su embalaje original sellado por el fabricante.
Un total de 3 Parts In-Stock de 3 Distributors
Información de envío
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía

Ofertas Disponibles (2)

M9F23408 product image
Schneider Electric

M9F23408

Condición:
Nuevos excedentes
Disponible:
1 pieza
En stock
Actualizado en: 08-11-2024
Oferta de:
FRProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
Garantía:
12 meses
1
M9F23408 product image
Schneider Electric

M9F23408

Condición:
Nuevos excedentes
Disponible:
1 pieza
En stock
Actualizado en: 08-11-2024
Oferta de:
GBProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
Garantía:
12 meses
1
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
€32.89

Complementary

[Ics] Rated Service Breaking Capacity
4.5 kA 75 % EN/IEC 60947-2 - 440 V AC || 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC || 15 kA 75 % EN/IEC 60947-2 - 240 V AC || 4.5 kA 75 % GB 14048.2 - 440 V AC || 7.5 kA 75 % GB 14048.2 - 415 V AC || 15 kA 75 % GB 14048.2 - 240 V AC
Height
81 mm
Contact Position Indicator
yes
Earth-Leakage Protection
without
Mounting Support
DIN rail
9 Mm Pitches
8
Wire Stripping Length
14 mm for top or bottom connection
Control Type
toggle
Connections - Terminals
tunnel type terminal top or bottom) 1-25 mm² AWG 18...AWG 8) - rigid || tunnel type terminal top or bottom) 1-16 mm² AWG 18...AWG 8) - flexible with ferrule || tunnel type terminal top or bottom) 1-16 mm² AWG 18...AWG 8) - flexible
[Ui] Rated Insulation Voltage
500 V AC EN/IEC 60947-2
Mounting Mode
clip-on
Electrical Durability
10000 cycles
Mechanical Durability
20000 cycles
Local Signalling
ON/OFF indication
[Uimp] Rated Impulse Withstand Voltage
6 kVEN/IEC 60947-2
Color
Gray
Width
72 mm
Provision For Padlocking
padlockable
Depth
72 mm
Tightening Torque
2.5-2.5 N.m top or bottom
Magnetic Tripping Limit
12 x In +/- 20 % AC
[Ue] Rated Operational Voltage
240 V AC 50/60 Hz || 415 V AC 50/60 Hz || 440 V AC 50/60 Hz

Specifications

Line Rated Current
8 A 25 °C EN/IEC 60947-2
Curve Code
D
Number Of Protected Poles
4
Network Type
AC
Standards
EN/IEC 60947-2 || GB 14048.2 || UL 1077 || CSA C22.2 No 235
Product Certifications
IEC || CCC || UR || CSA
Product Or Component Type
miniature circuit-breaker
Product Name
Multi9 C60
Range
Multi9
Breaking Capacity
14 kA AIR 240 V AC UL 1077 || 14 kA AIR 240 V AC CSA C22.2 No 235 || 10 kA AIR 480Y/277 V AC UL 1077 || 10 kA AIR 480Y/277 V AC CSA C22.2 No 235 || 6 kA Icu 440 V AC EN/IEC 60947-2 || 10 kA Icu 415 V AC EN/IEC 60947-2 || 20 kA Icu 240 V AC EN/IEC 60947-2 || 6 kA Icu 440 V AC GB 14048.2 || 10 kA Icu 415 V AC GB 14048.2 || 20 kA Icu 240 V AC GB 14048.2
Suitability For Isolation
yes EN/IEC 60947-2
Poles Description
4P
Device Application
distribution
Device Short Name
C60SP
Trip Unit Technology
thermal-magnetic

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1304004EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
N/A
Eu Rohs Directive
Compliant with Exemptions
Halogen Content Performance
Halogen free product

Environment

Ambient Air Temperature For Operation
-30-70 °C
Tropicalisation
2 IEC 60068-1
Ip Degree Of Protection
IP20 conforming to IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
Pollution Degree
3 EN/IEC 60947-2
Ambient Air Temperature For Storage
-40-80 °C
Relative Humidity
95-95 % 55-55 °C
Operating Altitude
0...6561.68 ft (0...2000 m)