This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 3P circuit breaker with 3 protected poles, 10A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 6 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 54mm x (H) 103mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
Country of Origin
FR
Part Number
M9F42310
Tariff Code
85362010
EAN
3606481169952
UNSPSC
39121603
€134.63
net
1
Métodos de pago:
Mejor oferta de:
DEProveedor de confianza de Automa.Net
Disponibilidad:
4 piezas
En stock
Actualizado en: 02-11-2024
Entrega Estimada:
Bajo pedido
Condición:
Nuevo Precintado de Fábrica
Nuevo Precintado de Fábrica - Un artículo completamente nuevo, sin usar, sin abrir, sin daños, en su embalaje original sellado por el fabricante.
Un total de 55 Parts In-Stock de 15 Distributors
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía

Ofertas Disponibles (15)

M9F42310 product image
Schneider Electric

M9F42310

Condición:
Nuevo Precintado de Fábrica
Disponible:
4 piezas
En stock
Actualizado en: 02-11-2024
Oferta de:
NLProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
€153.86
net
M9F42310 product image
Schneider Electric

M9F42310

Condición:
Nuevo Precintado de Fábrica
Disponible:
3 piezas
En stock
Actualizado en: 02-11-2024
Oferta de:
ESProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
€177.57
net
M9F42310 product image
Schneider Electric

M9F42310

Condición:
Nuevo Precintado de Fábrica
Disponible:
3 piezas
En stock
Actualizado en: 02-11-2024
Oferta de:
ITProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
€196.71
net
M9F42310 product image
Schneider Electric

M9F42310

Condición:
Nuevo Precintado de Fábrica
Disponible:
3 piezas
En stock
Actualizado en: 03-11-2024
Oferta de:
GBProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
£225.66
net
M9F42310 product image
Schneider Electric

M9F42310

Condición:
Nuevo Precintado de Fábrica
Disponible:
3 piezas
En stock
Actualizado en: 02-11-2024
Oferta de:
FRProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
€337.44
net
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
€18.14

Complementary

[Ics] Rated Service Breaking Capacity
4.5 kA 75 % EN/IEC 60947-2 - 440 V AC || 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC || 15 kA 75 % EN/IEC 60947-2 - 240 V AC || 4.5 kA 75 % GB 14048.2 - 440 V AC || 7.5 kA 75 % GB 14048.2 - 415 V AC || 15 kA 75 % GB 14048.2 - 240 V AC
Height
103 mm
Contact Position Indicator
yes
Earth-Leakage Protection
without
Mounting Support
DIN rail
9 Mm Pitches
6
Wire Stripping Length
14 mm for top or bottom connection
Control Type
toggle
Connections - Terminals
tunnel type terminal top or bottom) 1-25 mm² AWG 18...AWG 8) - rigid || tunnel type terminal top or bottom) 1-16 mm² AWG 18...AWG 8) - flexible with ferrule || tunnel type terminal top or bottom) 1-16 mm² AWG 18...AWG 8) - flexible
[Ui] Rated Insulation Voltage
500 V AC EN/IEC 60947-2
Mounting Mode
clip-on
Electrical Durability
10000 cycles
Mechanical Durability
20000 cycles
Local Signalling
ON/OFF indication
[Uimp] Rated Impulse Withstand Voltage
6 kVEN/IEC 60947-2
Color
Gray
Width
54 mm
Provision For Padlocking
padlockable
Depth
72 mm
Tightening Torque
2.5-2.5 N.m top or bottom
Magnetic Tripping Limit
8.5 x In +/- 20 % AC
[Ue] Rated Operational Voltage
240 V AC 50/60 Hz || 415 V AC 50/60 Hz || 440 V AC 50/60 Hz

Specifications

Line Rated Current
10 A 25 °C EN/IEC 60947-2
Curve Code
C
Number Of Protected Poles
3
Network Type
AC
Standards
EN/IEC 60947-2 || GB 14048.2 || UL 489 || CSA C22.2 No 5
Product Certifications
IEC || CCC || CSA || UL
Product Or Component Type
miniature circuit-breaker
Product Name
Multi9 C60
Range
Multi9
Breaking Capacity
6 kA Icu 440 V AC EN/IEC 60947-2 || 10 kA Icu 415 V AC EN/IEC 60947-2 || 20 kA Icu 240 V AC EN/IEC 60947-2 || 6 kA Icu 440 V AC GB 14048.2 || 10 kA Icu 415 V AC GB 14048.2 || 20 kA Icu 240 V AC GB 14048.2 || 14 kA AIR 240 V AC UL 489 || 10 kA AIR 480Y/277 V AC UL 489 || 14 kA AIR 240 V AC CSA C22.2 No 5 || 10 kA AIR 480Y/277 V AC CSA C22.2 No 5
Suitability For Isolation
yes EN/IEC 60947-2
Poles Description
3P
Device Application
distribution
Device Short Name
C60BP
Trip Unit Technology
thermal-magnetic

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1304004EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
N/A
Eu Rohs Directive
Compliant with Exemptions
Halogen Content Performance
Halogen free product

Environment

Ambient Air Temperature For Operation
-30-70 °C
Tropicalisation
2 IEC 60068-1
Ip Degree Of Protection
IP20 conforming to IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
Pollution Degree
3 EN/IEC 60947-2
Ambient Air Temperature For Storage
-40-80 °C
Relative Humidity
95-95 % 55-55 °C
Operating Altitude
0...6561.68 ft (0...2000 m)

Modelos CAD

traceparts
traceparts
Descargar