Schneider Electric

METSEION92040

PowerLogic™ ION9000 meter, DIN mount, 192 mm display, B2B adapter, HW kit
METSEION92040
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:
Un total de 1 Part In-Stock de 13 Distributors

Complementary

Network Frequency
50 Hz || 60 Hz
[Us] Rated Supply Voltage
90...480 V AC 45...66 Hz +/- 10 % || 90...120 V AC 400 Hz +/- 10 % || 110...480 V DC +/- 15 %
Communication Port Support
2 RS485 removable screw terminal block
Power Quality Analysis
EN 50160 compliance checking || IEEE 519 harmonic limit || IEC 61000-4-30 class A compliance reporting || IEEE 519 compliance reporting || waveform capture || total demand distortion || total harmonic distortion || up to the 63rd harmonic || up to the 127th harmonic with software || disturbance direction detection || dip, swell and transient || half cycle data acquisition || transient detection (20 µs)
Height
160 mm
Measurement Voltage
57-400 V AC 42...69 Hz between phase and neutral || 100-690 V AC 42...69 Hz between phases
Sampling Rate
1024 samples/cycle
Memory Capacity
2 GB
Number Of Outputs
4 digital || 2 form C relay output
Type Of Measurement
voltage sags and swells || current sags and swells || voltage || current || frequency || active and reactive power total || apparent power total || active and reactive power per phase || apparent power per phase || power factor total || power factor per phase || active and reactive energy || apparent energy || harmonic distorsion (I THD & U THD)
Communication Port Protocol
Modbus RTU 2400...115200 bps - 2-wire || ION 2400...115200 bps - 2-wire || DNP3 2400...115200 bps - 2-wire || Modbus TCP 10/100 Mbit/s || ION TCP 10/100 Mbit/s || DNP3 TCP 10/100 Mbit/s || IEC 61850 || Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s || DHCP || DNS || DLMS
Frequency Measurement Range
20-450 Hz
Communication Service
compliant reports || power quality summary || energy report || EcoStruxure Power Events Analysis || SMTP e-mail notification || SNMP
Ride-Through Time
100 ms 6 cycles at 60 Hz 120 V AC typical || 400 ms 24 cycles at 60 Hz 240 V AC typical || 1200 ms 72 cycles at 60 Hz 480 V AC typical
Port Ethernet
10/100BASE-TX 2 RJ45
Display Resolution
800 x 480 pixels
Power Consumption In Va
38 VA 480 V AC
Net Weight
1.5 kg
Tamperproof Of Settings
protected by sealable cover
Measurement Current
0.01-20 A
Electrical Insulation Class
class III EN/IEC 62052-11
Number Of Inputs
8 digital 30 V AC/60 V DC
Time Synchronisation Protocol
GPS || IRIG-B || NTP || SNTP || PTP
Measurement Accuracy
voltage +/- 0.1 % || current +/- 0.1 %
Ethernet Service
DHCP client || Device Profile Web Services (DPWS) || Rapid Scanning Tree Protocol (RSTP) || FTP/HTTP/HTTPS
Mounting Support
DIN rail meter device || door cut-out remote display
Communication Gateway
Ethernet/serial
Poles Description
3P + N + E
Data Recording
time stamping || min/max of instantaneous values || user-definable data logs || continuous logging or snapshot || trending/forecasting || event logs || alarm logs || configuration change || power outage || user login/logout || data logs || GPS synchronisation || sequence of event recording
Line Rated Current
1 A || 5 A
Cybersecurity
Syslog protocol support || robust security logs || port hardening || enable/disable communication ports || hardware metrology lock
Isolation Voltage
III400-690 V conforming to EN 61010-1:ed. 3 || III347-600 V conforming to UL 61010-1:ed. 3 || III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
Analogue Input Type
voltage (impedance 5 MOhm) || external CT (impedance 0.3 mOhm)5 x
Web Services
viewing of captured waveform || web page || pass/fail report for IEEE 519 || pass/fail report for EN 50160 || ITIC (CBEMA) curve || SEMI curve || NEMA motor derating curve || alarm notification by e-mail || TLS 1.2 || push historical data via mail
Width
160 mm
Display Type
remote LCD display || colour touchscreen
Depth
135.3 mm
Accuracy Class
class 0.1S active energy IEC 62053-22 || class 0.1 active energy IEC 61557-12 || class 0.1 active energy ANSI C12.20 || class 0.5S reactive energy IEC 62053-24 || class 0.1 current IEC 61557-12 || class 0.1 voltage IEC 61557-12 || class 0.1 active power IEC 61557-12 || class 0.5 power factor IEC 61557-12
Maximum Power Consumption In Va
80 VA 480 V AC

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1801009EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1801009EN
Eu Rohs Directive
Compliant with Exemptions

Environment

Ambient Air Temperature For Operation
-25-70 °C
Standards
ANSI C12.20 || ANSI C37.90.1 || IEC 61000-4-15 || IEC 61000-4-30 || IEC 61010-1 || IEC 61326-1 || IEC 61557-12 || IEC 61850 || IEC 62052-11 || IEC 62052-31 || IEC 62053-22 || IEC 62053-23 || IEC 62053-24 || IEC 62586 || UL 61010-1
Degree Of Protection
UL type 12, front
Electromagnetic Compatibility
EMC immunity conforming to IEC 62052-11 || EMC immunity conforming to IEC 61326-1 || EMC immunity conforming to IEC 61000-6-5 || electrostatic discharge immunity test conforming to IEC 61000-4-2 || immunity to radiated fields conforming to IEC 61000-4-3 || immunity to fast transients conforming to IEC 61000-4-4 || surge immunity test conforming to IEC 61000-4-5 || immunity to conducted disturbances conforming to IEC 61000-4-6 || immunity to magnetic fields at network frequency conforming to IEC 61000-4-8 || immunity to conducted disturbances - test level: 2...150 kHz conforming to CLC/TR 50579 || voltage dips and interruptions immunity test conforming to IEC 61000-4-11 || immunity to impulse waves conforming to IEC 61000-4-12 || conducted and radiated emissions conforming to EN 55011 || conducted and radiated emissions class B conforming to EN 55032 || conducted and radiated emissions class B conforming to FCC part 15 || conducted and radiated emissions class B conforming to ICES-003 || surge withstand conforming to ANSI C37.90.1 || surge withstand conforming to IEEE C37.90.1
Ambient Air Temperature For Storage
-40-85 °C
Relative Humidity
5-95 %
Quality Labels
ISO 9001 || ISO 14000
Ip Degree Of Protection
front IP65 || rear IP30
Operating Altitude
0...9842.52 ft (0...3000 m)
Installation Category
III

Specifications

Product Or Component Type
energy and power quality meter
Range
PowerLogic
Provided Equipment
remote display || remote display adapter || mounting instructions || Mounting Hardware
Device Application
power monitoring || WAGES metering || Net metering || medium voltage || high voltage
Device Short Name
ION92040
Metering Type
demand current I1, I2, I3, I4, I5 || peak demand currents || demand power P, Q, S || peak demand power PM, QM, SM || calculated active and reactive energy (+/- W.h, +/- VAR.h)

Documentos

Data Sheet

Descargar

Productos relacionados