Schneider Electric
METSEPM8240
1 / 1
Descripción
Activo maduro
The PowerLogic PM8000 series meters are compact, cost-effective multifunction power meters that will help you ensure reliability and efficiency of your power-critical facility. They reveal and provide understanding of complex power quality conditions enabling action to be taken to mitigate any issue. The PowerLogic PM8000 series meters have the versatility to perform nearly any job you need a meter to do, wherever you need it! The modular, flexible ION technology architecture enables a simple, building block approach for customizing each meter to any application. With patented Disturbance Direction Detection, revenue grade accuracy, multiple communication ports, onboard power quality analysis, web interface and a color graphical display. Certified by third party labs for energy accuracy (IEC 62052-11, IEC 62052-22, IEC 62052-24) and power quality (IEC 62586-2, IEC 61000-4-30 Class S). The PowerLogic PM8000 series provides data quality confidence you can count on. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol. Ability to enable/disable communication ports, and 50 user configurable accounts. With 512 MB of memory to support 50 data logs, 50+ user-definable alarms, waveform captures, 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 3 digital inputs and one digital output, plus the ability to add up to 4 option modules. I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Wide control power range of 90-415 VAC / 110-415 VDC. Operating environment of -25 to +70C; Humidity rating of 5% to 95%; Altitude up to 3000 m. Panel mounting (1/4 DIN) with integrated display.- Country of Origin
- CA
- Part Number
- METSEPM8240
- Tariff Code
- 90283090
- EAN
- 3606480701931
- UNSPSC
- 39121106
€1,710.29
net1
Métodos de pago:
- Mejor oferta de:
- Proveedor de confianza de Automa.Net
- Disponibilidad:
- 22 piezasEn stockActualizado en: 07-11-2024
- Entrega Estimada:
- Bajo pedido
- Condición:
- Nuevo Precintado de Fábrica
Nuevo Precintado de Fábrica - Un artículo completamente nuevo, sin usar, sin abrir, sin daños, en su embalaje original sellado por el fabricante.
Un total de 363 Parts In-Stock de 20 Distributors
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía
Ofertas Disponibles (20)
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
€1,444.04
Complementary
- Communication Network Type
- IPv6 (internet protocol)
- Network Frequency
- 50 Hz || 60 Hz
- Communication Port Support
- ETHERNET || screw terminal block RS485
- Power Quality Analysis
- EN 50160 2010 compliance report || IEEE 519 2014 compliance report || IEC 61000-4-30 class S power quality measurement || up to the 63rd harmonic || harmonic distortion || waveform capture || voltage sag and swell detection || programmablity (logic and math functions) || IEC 62586 power quality monitoring || disturbance direction detection || rapid voltage change
- Height
- 96 mm
- Measurement Voltage
- 57-400 V AC 42...69 Hz between phase and neutral || 100-690 V AC 42...69 Hz between phases
- Sampling Rate
- 256 samples/cycle
- Standards
- IEC 61557-12 || IEC 62052-11 || IEC 62053-24 || IEC 62053-22 || IEEE 1588 || IEC 62586-2 || IEC 61326-1
- Memory Capacity
- 512 MB
- Number Of Outputs
- 1 pulse
- Product Certifications
- CE || cULus || N998
- Type Of Measurement
- current || voltage || frequency || active and reactive power total || apparent power total || power factor total || active and reactive power per phase, rms || apparent power per phase, rms || power factor per phase, rms
- Communication Port Protocol
- Modbus RTU 115 kbauds - 2-wire || ION 115 kbauds - 2-wire || DNP3 || IEC 61850 || Modbus TCP/IP || Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s || RSTP 801.1d 2004
- Frequency Measurement Range
- 42-69 Hz
- Communication Service
- SMTP e-mail notification || RSTP support || NTP time synchronization || DHCP || PTP time synchronization
- Power Consumption In Va
- 18 VA 415 V AC
- Display Resolution
- 320 x 240 pixels QVGA
- Number Of Inputs
- 3 digital 30 V AC || 3 digital 60 V DC
- Net Weight
- 581 g
- Depth
- 77.5 mm
- Measurement Current
- 50-10000 mA
- Information Displayed
- voltage || current || frequency || power || energy consumption || harmonic distortion
- [Us] Rated Supply Voltage
- 90...415 V AC 45...65 Hz +/- 10 % || 110...415 V DC +/- 10 %
- Mounting Mode
- flush-mounted
- Measurement Accuracy
- current +/- 0.1 % || voltage +/- 0.1 % || active energy +/- 0.2 %
- Mounting Support
- framework
- Poles Description
- 3P + N || 3P || 1P + N
- Data Recording
- min/max of instantaneous values || waveform logs || sequence of event recording || time stamping || alarm logs || trending/forecasting || sag and swell logs || harmonics logs || GPS synchronisation || data logs || event logs || 50 data recorders
- Line Rated Current
- 1 A || 5 A || 10 A
- Cybersecurity
- enable/disable communication ports || password protection || Syslog protocol support || robust security logs || port hardening
- Isolation Voltage
- III400-690 V conforming to IEC 61010-1:ed. 3 || III400-690 V conforming to EN 61010-1:ed. 3 || III347-600 V conforming to UL 61010-1:ed. 3 || III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
- Analogue Input Type
- voltage (impedance 5 MOhm) || current (impedance 0.3 mOhm)
- Web Services
- customizable home page || file upload/download via FTP || file upload/download via SFTP || web server || alarm notification by e-mail || viewing of captured waveform (FTP) || viewing of captured waveform (web) || HTTPS server
- Width
- 96 mm
- Display Type
- colour TFT LCD
- Device Application
- power monitoring || WAGES metering
- Accuracy Class
- class 0.2S active energy IEC 62053-22 || class 0.2 active energy ANSI C12.20 || class 0.2 active power IEC 61557-12 || class 0.5S reactive energy IEC 62053-24 || class 0.5 power factor IEC 61557-12 || class 0.2 voltage IEC 61557-12 || class 0.2 current IEC 61557-12
- Installation Category
- III
Environment
- Ambient Air Temperature For Operation
- -25-70 °C
- Electromagnetic Compatibility
- electrostatic discharge conforming to IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 || electrical fast transient/burst immunity test conforming to IEC 61000-4-4 || surge immunity test conforming to IEC 61000-4-5 || conducted RF disturbances conforming to IEC 61000-4-6 || magnetic field at power frequency conforming to IEC 61000-4-8 || voltage dips and interruptions immunity test conforming to IEC 61000-4-11 || immunity to impulse waves conforming to IEC 61000-4-12 || conducted and radiated emissions conforming to EN 55022 || conducted and radiated emissions conforming to EN 55011 || conducted and radiated emissions conforming to FCC part 15 || conducted and radiated emissions conforming to ICES-003 || conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579 || surge withstand conforming to IEEE C37.90.1
- Ambient Air Temperature For Storage
- -40-85 °C
- Relative Humidity
- 5-95 %
- Ip Degree Of Protection
- front IP54 IEC 60529 || body IP30 IEC 60529
- Operating Altitude
- 9842.52 ft (3000 m)
Specifications
- Product Or Component Type
- power meter
- Product Name
- PowerLogic PM8000
- Range
- PowerLogic
- Device Short Name
- PM8240
Offer Sustainability
- Environmental Disclosure
- ENVPEP1406023EN
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI1406023EN
- Eu Rohs Directive
- Compliant with Exemptions
Modelos CAD