Descripción

Activo maduro
Solar ready combination service entrance devices are available with ring or ringless type meter socket designs. Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires. These solar ready combination service entrance devices meet the California Title 24 requirements and are suitable for use with Photovoltaic system applications. This Homeline combination service entrance meter main unit has a ringless meter socket with a horn bypass. The main service disconnect is rated at 200 A and has a short circuit rating 22 kA. It has a Homeline plug on neutral load center that has 8 spaces and 16 circuits. This unit has a NEMA 3R enclosure that is surface mounted and underground service feed only. The line side lugs will accept 4 AWG to 300 kcmil copper or aluminum wire. The service ground lug will accept 8 AWG to 2/0 AWG copper or aluminum wire. This QO combination service entrance meter main unit is UL Listed and meets EUSERC standards.
Part Number
RU816M200PS
Tariff Code
8538908160
UPC
785901994213
UNSPSC
39121102
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:
Solicite un presupuesto y le enviaremos información sobre disponibilidad y precio.

Complementary

Connections - Terminals
plug-on neutral
Height
27.87 in
Tightening Torque
line side 250 lb.in, AWG 4...300 kcmil, aluminium/copper || service ground 50 lb.in, AWG 8...AWG 2/0, aluminium/copper || branch lugs 50 lb.in, AWG 3...AWG 1/0, aluminium/copper || branch lugs 45 lb.in, AWG 4, aluminium/copper || branch lugs 45 lb.in, AWG 6, aluminium/copper || branch lugs 40 lb.in, AWG 8, aluminium/copper || branch lugs 35 lb.in, AWG 14...AWG 10, copper || branch lugs 35 lb.in, AWG 12...AWG10, aluminium
Branch Circuit Breaker Rated Current
110 A
Bypass Type
no bypass
Service Feed Location
UG
Electrical Connection
lugs, line side || lugs, service ground
Number Of Circuits
16
Number Of Spaces
8
Phase
single phase
Short-Circuit Current
22 kA
Service Disconnect Rated Current
200 A
Line Rated Current
200 A
Width
15.04 in
Awg Gauge
AWG 4...300 kcmil (aluminium/copper) line side || AWG 8...AWG 2/0 (aluminium/copper) service ground
Depth
6.53 in
Product Compatibility
solar ready
Colour Of Enclosure
grey
Device Composition
service disconnect (factory installed)
Device Mounting
surface

Specifications

Range Of Product
Homeline
Product Or Component Type
Meter Mains
Hub Type
A-L
Meter Socket Type
ringless

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1407020EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
N/A
Eu Rohs Directive
Compliant with Exemptions

Environment

Product Certifications
UL Listed || ANSI
Nema Degree Of Protection
NEMA 3R

Documentos