Descripción

Activo maduro
This Harmony XALD yellow control station with 3 functions is ideal for your complete control station. It operates with spring return mechanism and uses screw-clamp terminals. This control station with 3 push buttons for 3 functions enables machine builders to easily add required control and signalling functionality on their machines. Its schematic is clearly distinguishable thanks to clear colors and markings. It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant thanks to its IP69 / IP67 / IP66 / IP69K, making it ideal for operation in harsh environments. Its wide range of operating temperatures from -40°C to 70°C allows versatility in usage of product. Vibration resistant screw clamp connection terminals ensure high vibration resistance making product suitable installation on high impact machine.
Country of Origin
FR
Part Number
XALD311H29H7
Tariff Code
8537109170
EAN
39121561
UNSPSC
39121561
Métodos de pago:
Mejor oferta de:
DEProveedor de confianza de Automa.Net
Disponibilidad:
1 pieza
En stock
Actualizado en: 08-11-2024
Garantía:
12 meses
Entrega Estimada:
Bajo pedido
Condición:
Nuevos excedentes
Nuevos excedentes - Un artículo nuevo, sin usar, sin daños y sin garantía del fabricante. El artículo puede venir sin embalaje original o en embalaje de reemplazo. Si se proporciona, es posible que la caja haya sido abierta.
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía

Environment

Product Certifications
UL Listed || CSA
Ik Degree Of Protection
IK03 IEC 62262
Ambient Air Temperature For Operation
-40-70 °C
Standards
UL 508 || IEC 60947-5-5 || IEC 60947-5-4 || IEC 60947-1 || IEC 60947-5-1 || CSA C22.2 No 14 || JIS C8201-5-1 || JIS C8201-1
Shock Resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Vibration Resistance
5 gn 12-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP66 IEC 60529 || IP69 || IP69K || IP67
Ambient Air Temperature For Storage
-40-70 °C
Nema Degree Of Protection
NEMA 13 || NEMA 4X
Electrical Shock Protection Class
class II IEC 60536
Protective Treatment
TH

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1806010EN
Sustainable Offer Status
Green Premium product
Toxic Heavy Metal Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Reach Free Of Svhc
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1806010EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Operating Force
3.5 N NC changing electrical state || 3.8 N NO changing electrical state
Short-Circuit Protection
10 A cartridge fuse gG IEC 60947-5-1
Operating Travel
1.5 mm NC changing electrical state) || 2.6 mm NO changing electrical state) || 4.3 mm total travel)
Contacts Material
silver alloy (Ag/Ni)
Positive Opening
with IEC 60947-5-1 appendix K
[Ith] Conventional Free Air Thermal Current
10 A IEC 60947-5-1
Cable Entry
2 knock-outs for cable entry 14-14 mm || 2 knock-outs for Pg 13 cable gland and ISO M20 12-12 mm
Net Weight
0.299 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947-1
Resistance To High Pressure Washer
7000000 Pa 55 °C 0.1 m
Electrical Durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
Connections - Terminals
screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1
[Ui] Rated Insulation Voltage
600 V 3)IEC 60947-1
[Ie] Rated Operational Current
6 A 120 V, AC-15, A600 IEC 60947-5-1 || 3 A 240 V, AC-15, A600 IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1
Mechanical Durability
10000000 cycles
Electrical Reliability
λ < 10exp(-6) 5 V 1 mA IEC 60947-5-4 || λ < 10exp(-8) 17 V 5 mA IEC 60947-5-4
Tightening Torque
0.8-1.2 N.m IEC 60947-1
Shape Of Screw Head
cross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm

Specifications

Control Station Application
three functions
Product Destination
for XB5 Ø 22 mm control and signalling units
Range Of Product
Harmony XALD
Colour Of Base Of Enclosure
light grey RAL 7035)
Control Station Composition
1 flush push-button, red 1 NC O || 1 flush push-button, green 1 NO REVERSE || 1 flush push-button, green 1 NO FORWARD
Operators Description
green ''FORWARD'' 1 NO - red ''O'' 1 NC - green ''REVERSE'' 1 NO
Product Or Component Type
complete control station
Material
polycarbonate
Marking Location
marking on legend holder
Operator Profile
3 flush push-buttons
Colour Of Cover
dark grey RAL 7016)
Contact Operation
slow-break
Device Short Name
XALD

Documentos

Data Sheet