- Contacts Usage
- monitoring contact
- Height
- 43 mm
- Operating Force
- 47 N
- Short-Circuit Protection
- 6 A cartridge fuse gG IEC 60947-5-1
- Fixing Mode
- fixing nut 2.2 N.m +/- 0.2)
- Operating Travel
- 1.5 mm NC changing electrical state) || 4.3 mm total travel)
- Contacts Material
- silver alloy (AgNi) || silver alloy (AgSnO2)
- Positive Opening
- with IEC 60947-5-1 appendix K
- [Ith] Conventional Free Air Thermal Current
- 6 A IEC 60947-5-1
- Net Weight
- 0.050 kg
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV IEC 60947-1
- Electrical Durability
- 300000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 300000 cycles, AC-15, 3 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 300000 cycles, AC-15, 3 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 300000 cycles, DC-13, 0.3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 300000 cycles, DC-13, 1 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
- [Ui] Rated Insulation Voltage
- 300 V 3)IEC 60947-1
- [Ie] Rated Operational Current
- 1.5 A 240 V, AC-15, B300 IEC 60947-5-1 || 3 A 120 V, AC-15, B300 IEC 60947-5-1 || 0.11 A 250 V, DC-13, R300 IEC 60947-5-1 || 0.22 A 125 V, DC-13, R300 IEC 60947-5-1
- Mechanical Durability
- 300000 cycles
- Electrical Reliability
- λ < 10exp(-6) 5 V, 1 mA in clean environment IEC 60947-5-4 || λ < 10exp(-8) 17 V, 3.4 mA in clean environment IEC 60947-5-4
- Width
- 40 mm
- Depth
- 85 mm
- Tightening Torque
- 0.8-1.2 N.m IEC 60947-1
- Shape Of Screw Head
- cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm
- Device Mounting
- fixing hole 22.5 mm +/- 0.2 mm