This product is an industrial EN 50041 format limit switch with 1 Pg 13.5 cable entry. It features a metal fixed body and a rotary head, with a variable length thermoplastic roller lever. Contacts: 2-pole NC + NO, break before make, slow break. This limit switch is supplied for actuation from left and right. The XCKJ range offers the most robust heads in his category.- Country of Origin
- FR
- Part Number
- XCKJ50541
- Tariff Code
- 85365080
- EAN
- 3389110646085
- UNSPSC
- 39122213
Métodos de pago:
- Mejor oferta de:
- Proveedor de confianza de Automa.Net
- Disponibilidad:
- 1 piezaEn stockActualizado en: 08-11-2024
- Garantía:
- 12 meses
- Entrega Estimada:
- Bajo pedido
- Condición:
- Nuevos excedentes
Nuevos excedentes - Un artículo nuevo, sin usar, sin daños y sin garantía del fabricante. El artículo puede venir sin embalaje original o en embalaje de reemplazo. Si se proporciona, es posible que la caja haya sido abierta.
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía
Specifications
- Movement Of Operating Head
- rotary
- Range Of Product
- Telemecanique Limit switches XC Standard
- Fixing Mode
- by the body
- Type Of Operator
- spring return roller lever thermoplastic variable length
- Cable Entry
- 1 entry tapped for Pg 13.5 cable gland 9-12 mm
- Product Or Component Type
- limit switch
- Head Material
- zamak
- Material
- metal
- Head Type
- rotary head
- Type Of Approach
- lateral approach, 1 or 2 programmable direction
- Series Name
- standard format
- Contacts Type And Composition
- 1 NC + 1 NO
- Body Type
- fixed
- Contact Operation
- slow-break, break before make
- Body Material
- zamak
- Device Short Name
- XCKJ
- Number Of Poles
- 2
Contractual warranty
- Warranty
- 18 months
Complementary
- Height
- 77-77 mm
- Terminals Description Iso N°1
- (13-14)NO || (21-22)NC
- Short-Circuit Protection
- 10 A cartridge fuse gG
- Minimum Actuation Speed
- 6 m/min
- Electrical Connection
- screw-clamp terminals 1 x 0.5...2 x 2.5 mm²
- Number Of Steps
- 1
- [Ithe] Conventional Enclosed Thermal Current
- 10 A
- Net Weight
- 0.485 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60664 || 6 kV IEC 60947-1
- Switch Actuation
- by 30° cam
- [Ui] Rated Insulation Voltage
- 300 VUL 508 || 500 V 3)IEC 60947-1 || 300 VCSA C22.2 No 14
- Electrical Durability
- 5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
- Positive Opening
- without
- Contacts Insulation Form
- Zb
- [Ie] Rated Operational Current
- 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
- Mechanical Durability
- 30000000 cycles
- Maximum Actuation Speed
- 1.5 m/s
- Width
- 40 mm
- Depth
- 44 mm
- Minimum Torque For Tripping
- 0.25 N.m
- Maximum Resistance Across Terminals
- 25 MOhm IEC 60255-7 category 3
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP110614EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- CCC || UL || CSA
- Ik Degree Of Protection
- IK07 EN 50102
- Ambient Air Temperature For Operation
- -25-70 °C
- Standards
- IEC 60204-1 || EN 60204-1 || CSA C22.2 No 14 || UL 508 || CENELEC EN 50041 || IEC 60947-5-1 || EN 60947-5-1
- Shock Resistance
- 50 gn 11 ms IEC 60068-2-27
- Vibration Resistance
- 25 gn 10-500 Hz)IEC 60068-2-6
- Ip Degree Of Protection
- IP66 conforming to IEC 60529
- Ambient Air Temperature For Storage
- -40-70 °C
- Overvoltage Category
- class I IEC 61140 || class I NF C 20-030
- Protective Treatment
- TH