Limit switch, Limit switches XC Standard, XCKT, steel roller plunger, 1NC+1 NO, snap, 1/2NPT
XCKT2102N12
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:
Oferta con plazo de entrega del fabricante
Entrega:1 - 2 días laborables
El mejor precio:
Enviar solicitud de precio

Additional Information

Part Number
XCKT2102N12
UNSPSC
39122213
Tariff Code
8536509055
Country of Origin
FR

Specifications

Type Of Approach
lateral approach, 2 directions
Series Name
standard format
Contacts Type And Composition
1 NC + 1 NO
Movement Of Operating Head
linear
Body Type
fixed
Range Of Product
Telemecanique Limit switches XC Standard
Contact Operation
snap action
Fixing Mode
by the body
Type Of Operator
spring return roller plunger metal
Sensor Design
compact form C CENELEC EN 50047
Body Material
plastic
Product Or Component Type
limit switch
Head Material
zamak
Material
plastic
Device Short Name
XCKT
Number Of Poles
2
Head Type
plunger head

Contractual warranty

Warranty
18 months

Complementary

Switch Actuation
by 30° cam
[Ui] Rated Insulation Voltage
300 VUL 508 || 500 V 3)IEC 60947-1 || 300 VCSA C22.2 No 14
Short-Circuit Protection
10 A cartridge fuse gG
Electrical Durability
5000000 cycles, DC-13, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Positive Opening Minimum Force
36 N
Positive Opening
with
Contacts Insulation Form
Zb
Electrical Connection
screw-clamp terminals 1 x 0.34...2 x 1.5 mm²
Mechanical Durability
10000000 cycles
Maximum Actuation Speed
0.5 m/s
Cable Entry
2 entries tapped for 1/2" NPT cable gland
Minimum Force For Tripping
12 N
Contact Code Designation
A300, AC-15 (Ue = 240 V), Ie = 3 A 10 A EN/IEC 60947-5-1 appendix A || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 appendix A
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60664 || 6 kV IEC 60947-1
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Circularity Profile
ENVEOLI110603EN
Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110606EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
UL || CCC || CSA
Ik Degree Of Protection
IK04 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
EN 60947-5-1 || IEC 60204-1 || UL 508 || EN 60204-1 || CSA C22.2 No 14 || IEC 60947-5-1
Electrical Shock Protection Class
class II IEC 61140 || class II NF C 20-030
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Vibration Resistance
25 gn 10-500 Hz)IEC 60068-2-6
Protective Treatment
TC
Ip Degree Of Protection
IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529