1 / 1
thumbnail

Descripción

Activo maduro
This product is part of the XCS range, an offer of safety switches. The safety switch is an electrical switch that makes or breaks contact in the presence of a magnetic field. This safety switch has 2 NC and 1 NO, slow break, break before make, NC contacts with the positive opening operation. The switch with a rated operating current of 6A at 120V AC, 3A at 240V AC, 0.55A at 125V DC, 0.27A at 250V DC and conventional enclosed thermal current of 10A. It is furnished with screw clamp terminals for electrical connection and 1 entry tapped for M20 x 1.5 cable gland. It is an IP67 rated product. The key operated turret head has an industrial metal body, made of Zamak. Its dimensions are 40mm (width) x 44mm (depth) x 114mm (height). It weighs 0.44kg. It is intended as far as safety is concerned all dangerous machines in all sectors are involved, such as packaging, robotics, machine tools and automotive sectors. This product is certified by CSA and UL. It meets EN/ISO 12100, CSA C22.2 No 14, EN/IEC 60204-1, UL 508, EN 1088/ISO 14119 and EN/IEC 60947-5-1 standards. The XCS safety switches is one of the most comprehensive ranges of industrial safety switches on the market, providing a range of options for most machine applications. XCS safety switches are designed for the protection of operators, by controlling the safe opening and interlocking of guards and covers in installations.
Country of Origin
FR
Part Number
XCSA712
Tariff Code
85365080
EAN
3389110718973
UNSPSC
39122213
Métodos de pago:
Mejor oferta de:
GBProveedor de confianza de Automa.Net
Disponibilidad:
1 pieza
En stock
Actualizado en: 21-10-2024
Entrega Estimada:
Bajo pedido
Condición:
Nuevos excedentes
Nuevos excedentes - Un artículo nuevo, sin usar, sin daños y sin garantía del fabricante. El artículo puede venir sin embalaje original o en embalaje de reemplazo. Si se proporciona, es posible que la caja haya sido abierta.
Un total de 2 Parts In-Stock de 2 Distributors
Entrega desde:
GB
GB
DE
DE
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía

Ofertas Disponibles (1)

XCSA712 product image
Schneider Electric

XCSA712

Condición:
Nuevos excedentes
Disponible:
1 pieza
En stock
Actualizado en: 08-11-2024
Oferta de:
DEProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
Garantía:
12 meses
1
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
Enviar solicitud de precio

Specifications

Range Of Product
Telemecanique Safety switches XCS
Cable Entry
1 entry tapped M20 x 1.5
Electrical Connection
terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
Locking Options Description
without locking of actuator
Product Or Component Type
safety switch
Signalling Circuit Voltage
24/48 V
Component Name
XCSA
Design
industrial
Material
metal
Head Type
key operated turret head
Contacts Type And Composition
2 NC + 1 NO
Contact Operation
slow-break, break before make
Local Signalling
for on opening of NC contacts 1 LED (orange)
Cable Outer Diameter
7-13 mm
Number Of Poles
3

Contractual warranty

Warranty
18 months

Complementary

Height
114-114 mm
Short-Circuit Protection
10 A cartridge fuse gG (gl)
Minimum Actuation Speed
0.01 m/s
[Ithe] Conventional Enclosed Thermal Current
10 A
Head Material
zamak
Signalling Circuit Type
AC/DC
Net Weight
0.44 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-5-1
Maximum Operating Rate
10 cyc/mn for maximum durability
[Ui] Rated Insulation Voltage
300 VUL 508 || 500 VEN/IEC 60947-1 || 300 VCSA C22.2 No 14
Positive Opening
with NC contact
[Ie] Rated Operational Current
6 A 120 V, AC-15, A300 EN/IEC 60947-5-1 || 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1
Minimum Actuator Force For Extraction
20 N
Mechanical Durability
1000000 cycles
Maximum Actuation Speed
0.5 m/s
Body Material
zamak
Safety Reliability Data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Width
40 mm
Depth
44 mm
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110614EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
UL || CSA
Ambient Air Temperature For Operation
-25-70 °C
Standards
EN/ISO 12100 || CSA C22.2 No 14 || EN/IEC 60204-1 || UL 508 || EN 1088/ISO 14119 || EN/IEC 60947-5-1
Shock Resistance
10 gn 11 ms IEC 60068-2-27
Vibration Resistance
5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class I EN/IEC 61140
Protective Treatment
TC