Specifications
- Range Of Product
- Telemecanique Safety switches XCS
- [Ue] Rated Operational Voltage
- 24 V DC
- Cable Length
- 0.15 m
- Product Or Component Type
- coded magnetic switch
- Component Name
- XCSDMP
- Design
- rectangular, standard
- Material
- plastic
- Size
- 88 x 25 x 13 mm
- Connector Type
- M12
- Contacts Type And Composition
- 1 NC + 1 NO
- Contact Operation
- staggered
- Electrical Connection
- connector on flying lead
- Approach Directions
- 3 directions
- [Ui] Rated Insulation Voltage
- 100 V DC
- Number Of Poles
- 2
Contractual warranty
- Warranty
- 18 months
Complementary
- Maximum [Ie] Rated Operational Current
- 100 mA
- Height
- 88 mm
- Switching Frequency
- 150 Hz
- Short-Circuit Protection
- 500 mA external cartridge fuse gG (gl)
- Switching Capacity In Ma
- 0.1...100 mA
- [Sar] Assured Tripping Distance
- 20 mm
- Contacts Material
- rhodium
- Insulation Resistance
- 1000 MOhm
- Resistance Across Terminals
- 10 Ohm
- Net Weight
- 0.18 kg
- [Uimp] Rated Impulse Withstand Voltage
- 2.5 kV EN/IEC 60947-5-1
- Maximum Switching Voltage
- 100 V DC
- [Sa] Assured Operating Distance
- 8 mm
- Cable Material
- PVC
- Breaking Capacity
- 10 VA
- Safety Reliability Data
- B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
- Enclosure Material
- thermoplastic PBT
- Width
- 25 mm
- Depth
- 13 mm
- Electrical Durability
- 1200000 cycles
- Safety Level
- can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- CSA || UL
- Ambient Air Temperature For Operation
- -25-85 °C
- Standards
- EN/ISO 12100 || EN/IEC 60204-1 || EN/IEC 60947-5-1 || CSA C22.2 No 14 || ISO 14119 || UL 508
- Shock Resistance
- 30 gn 11 ms IEC 60068-2-27
- Vibration Resistance
- 10 gn 10-150 Hz)IEC 60068-2-6
- Ip Degree Of Protection
- IP67 conforming to IEC 60529
- Ambient Air Temperature For Storage
- -40-85 °C
- Electrical Shock Protection Class
- class II EN/IEC 61140
- Maximum Sensitivity To Magnetic Fields
- 0.3 mT
- Protective Treatment
- TH