Schneider Electric

XCSLF2525342

1 / 1
thumbnail

Descripción

Activo maduro
This product is part of the XCS range, an offer of safety switches. The safety switch is an electrical switch that makes or breaks contact in the presence of a magnetic field. It has 2 normally closed + 2 normally opened, slow-break, break before make contacts, normally closed contact with positive opening operation. It is a switch with a rated operational current of 0.75A at 240V AC, 0.55A at 24V DC and a conventional enclosed thermal current of 4A. It is furnished with spring terminals for electrical connection and 3 cable entry tapped for M20 x 1.5 cable gland. The electromagnet interlocking on de-energization and unlocking on energization of solenoid. It offers long mechanical durability which is about 1 million operating cycles. It is an IP66 and IP67 rated product. The key operated turret head limit switch has a slim metal body which is made of Zamak. Its dimensions are 44mm (Width) x 51mm (Depth) x 205mm (Height) and weighs 1.1kg. It is intended as far as safety is concerned all dangerous machines in all sectors are involved. Such as packaging, handling, robotics, machine tools, presses, automotive sector. This product is certified by TÜV, CSA and UL. It meets CSA C22.2 No 14, EN 60947-5-1, EN/ISO 13849-1, EN/IEC 62061, EN 1088/ISO 14119 and UL 508 standards. One of the most comprehensive ranges of industrial safety switches on the market. These safety interlock switches are suitable for protecting operators of potentially dangerous machines with inertia. Safety switches for the protection of operators, by controlling the safe opening and interlocking of guards and covers in your installations.
Country of Origin
ID
Part Number
XCSLF2525342
Tariff Code
85365080
EAN
3606489413330
UNSPSC
39122213
Métodos de pago:
Mejor oferta de:
GBProveedor de confianza de Automa.Net
Disponibilidad:
1 pieza
En stock
Actualizado en: 21-10-2024
Entrega Estimada:
Bajo pedido
Condición:
Nuevos excedentes
Nuevos excedentes - Un artículo nuevo, sin usar, sin daños y sin garantía del fabricante. El artículo puede venir sin embalaje original o en embalaje de reemplazo. Si se proporciona, es posible que la caja haya sido abierta.
Un total de 2 Parts In-Stock de 2 Distributors
Entrega desde:
GB
GB
DE
DE
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía

Ofertas Disponibles (1)

XCSLF2525342 product image
Schneider Electric

XCSLF2525342

Condición:
Nuevos excedentes
Disponible:
1 pieza
En stock
Actualizado en: 08-11-2024
Oferta de:
DEProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
Garantía:
12 meses
1
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
Enviar solicitud de precio

Specifications

[Us] Rated Supply Voltage
230 V - 15...10 %
Range Of Product
Telemecanique Safety switches XCS
Cable Entry
3 entries tapped M20 x 1.5
Electrical Connection
spring terminal 1 x 1.5 mm² flexible or solid cable || spring terminal 2 x 0.5 mm² flexible cables with 13 mm bared ends
Locking Options Description
with interlocking, locking by solenoid
Solenoid Contacts Type And Composition
1 NC + 1 NO slow-break, break before make)
Product Or Component Type
safety switch
Signalling Circuit Voltage
230 V
Component Name
XCSLF
Design
slim
Material
metal
Head Type
key operated turret head
Contacts Type And Composition
1 NC + 1 NO
Contact Operation
slow-break, break before make
Local Signalling
for actuator withdrawn 1 LED (orange) || for actuator inserted and locked 1 LED (green)
Electromagnet Interlocking
locking on de-energisation and unlocking on energisation of solenoid
Cable Outer Diameter
7-13 mm
Number Of Poles
2

Contractual warranty

Warranty
18 months

Complementary

Minimum Switching Current
10 mA at 20 °C
Height
205-205 mm
Maximum Load Current
<= 15 A
Short-Circuit Protection
4 A cartridge fuse gG (gl) || 6 A fast blow
Minimum Actuation Speed
0.01 m/s
[Ithe] Conventional Enclosed Thermal Current
4 A
Supply Voltage Type
AC/DC
Head Material
zamak
Signalling Circuit Type
AC
Net Weight
1.1 kg
[Uimp] Rated Impulse Withstand Voltage
4 kV EN/IEC 60947-5-1
Maximum Operating Rate
10 cyc/mn for maximum durability
[Ui] Rated Insulation Voltage
300 VUL 508 || 300 VCSA C22.2 No 14 || 250 V 3)EN/IEC 60947-1
Positive Opening
with NC contact
Load Factor
1
[Ie] Rated Operational Current
0.55 A 24 V, DC-13, R300 EN/IEC 60947-5-1 || 0.75 A 240 V, AC-15, C300 EN/IEC 60947-5-1
Minimum Actuator Force For Extraction
20 N
Mechanical Durability
1000000 cycles
Maximum Actuation Speed
0.5 m/s
Body Material
zamak
Safety Reliability Data
B10d = 5500000 value given for a life time of 20 years limited by mechanical or contact wear
Width
44 mm
Depth
51 mm
Minimum Switching Voltage
17 V
Maximum Actuator Forcible Withdrawal Rtc
3000 N
Resistance To Mechanical Impact
9.6 J against the partition || 6.4 J without partition
Supply Frequency
50/60 Hz
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110916EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile
ENVEOLI110903EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
TÜV || UL || CSA
Ambient Air Temperature For Operation
-25-60 °C
Standards
UL 508 || EN/IEC 60204-1 || CSA C22.2 No 14 || EN/IEC 62061 || EN 1088/ISO 14119 || EN/ISO 13849-1 || EN/IEC 60947-5-1
Shock Resistance
10 gn 11 ms IEC 60068-2-27
Vibration Resistance
5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP66 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 || IP67
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class I EN/IEC 61140
Protective Treatment
TC