This product is part of the XCS range, an offer of safety switches for protection of operators and machine safety also. The safety switch is an electrical switch that makes or breaks contact in the presence of a magnetic field. It has 4 normally closed + 2 normally opened, slow-break, break before make contacts, normally closed contact with positive opening operation. It is a limit switch with a rated operating current of 0.55A at 24V, 0.75A at 240V and conventional enclosed thermal current of 4A. It is furnished with spring terminals for electrical connection and 3 cable entries tapped for 1/2inch NPT. The electromagnet interlocking on de-energization and unlocking on energization of the solenoid. It offers mechanical durability of about 1 million operating cycles. It is an IP66 and IP67 rated product. This key operated turret head limit switch has a slim metal body which is made of Zamak. Its dimensions are 44mm (width) x 51mm (depth) x 205mm (height) and weighs 1.1kg. It is intended as far as safety is concerned all dangerous machines in all sectors are involved, such as packaging, handling, robotics, machine tools, presses and the automotive sector. This product is certified by UL, TÜV and CSA. It complies with UL 508, EN/ISO 13849-1, EN/IEC 62061, EN 60947-5-1, EN 1088/ISO 14119 and CSA C22.2 No 14 standards. One of the most comprehensive catalogues of industrial safety switches on the market. Save time in setting up, place and in the cabinet with innovative coded magnetic system. These safety switches for controlling the safe opening and interlocking of guards and covers in your installations.- Country of Origin
- ID
- Part Number
- XCSLF3737513
- Tariff Code
- 85365080
- EAN
- 3606489413514
- UNSPSC
- 39122213
Métodos de pago:
- Mejor oferta de:
- Proveedor de confianza de Automa.Net
- Disponibilidad:
- 1 piezaEn stockActualizado en: 08-11-2024
- Garantía:
- 12 meses
- Entrega Estimada:
- Bajo pedido
- Condición:
- Nuevos excedentes
Nuevos excedentes - Un artículo nuevo, sin usar, sin daños y sin garantía del fabricante. El artículo puede venir sin embalaje original o en embalaje de reemplazo. Si se proporciona, es posible que la caja haya sido abierta.
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía
Specifications
- [Us] Rated Supply Voltage
- 24 V - 15...10 %
- Range Of Product
- Telemecanique Safety switches XCS
- Cable Entry
- 3 entries tapped 1/2" NPT
- Electrical Connection
- spring terminal 1 x 1.5 mm² flexible or solid cable || spring terminal 2 x 0.5 mm² flexible cables with 13 mm bared ends
- Locking Options Description
- with interlocking, locking by solenoid
- Solenoid Contacts Type And Composition
- 2 NC + 1 NO slow-break, break before make)
- Product Or Component Type
- safety switch
- Signalling Circuit Voltage
- 24 V
- Component Name
- XCSLF
- Design
- slim
- Material
- metal
- Head Type
- key operated turret head
- Contacts Type And Composition
- 2 NC + 1 NO
- Contact Operation
- slow-break, break before make
- Local Signalling
- for actuator withdrawn 1 LED (orange) || for actuator inserted and locked 1 LED (green)
- Electromagnet Interlocking
- locking on energisation and unlocking on de-energisation of solenoid
- Number Of Poles
- 3
Contractual warranty
- Warranty
- 18 months
Complementary
- Minimum Switching Current
- 10 mA at 20 °C
- Height
- 205-205 mm
- Maximum Load Current
- <= 15 A
- Short-Circuit Protection
- 4 A cartridge fuse gG (gl) || 6 A fast blow
- Minimum Actuation Speed
- 0.01 m/s
- [Ithe] Conventional Enclosed Thermal Current
- 4 A
- Supply Voltage Type
- AC/DC
- Head Material
- zamak
- Signalling Circuit Type
- AC/DC
- Net Weight
- 1.1 kg
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV EN/IEC 60947-5-1
- Maximum Operating Rate
- 10 cyc/mn for maximum durability
- [Ui] Rated Insulation Voltage
- 300 VUL 508 || 300 VCSA C22.2 No 14 || 250 V 3)EN/IEC 60947-1
- Positive Opening
- with NC contact
- Load Factor
- 1
- [Ie] Rated Operational Current
- 0.55 A 24 V, DC-13, R300 EN/IEC 60947-5-1 || 0.75 A 240 V, AC-15, C300 EN/IEC 60947-5-1
- Minimum Actuator Force For Extraction
- 20 N
- Mechanical Durability
- 1000000 cycles
- Maximum Actuation Speed
- 0.5 m/s
- Body Material
- zamak
- Safety Reliability Data
- B10d = 5500000 value given for a life time of 20 years limited by mechanical or contact wear
- Width
- 44 mm
- Depth
- 51 mm
- Minimum Switching Voltage
- 17 V
- Maximum Actuator Forcible Withdrawal Rtc
- 3000 N
- Resistance To Mechanical Impact
- 9.6 J against the partition || 6.4 J without partition
- Supply Frequency
- 50/60 Hz
- Safety Level
- can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 EN/IEC 61508
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP110916EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Circularity Profile
- ENVEOLI110903EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- UL || CSA || TÜV
- Ambient Air Temperature For Operation
- -25-60 °C
- Standards
- CSA C22.2 No 14 || EN 1088/ISO 14119 || EN/IEC 62061 || EN/IEC 60204-1 || EN/ISO 13849-1 || UL 508 || EN/IEC 60947-5-1
- Shock Resistance
- 10 gn 11 ms IEC 60068-2-27
- Vibration Resistance
- 5 gn 10-500 Hz)IEC 60068-2-6
- Ip Degree Of Protection
- IP66 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 || IP67
- Ambient Air Temperature For Storage
- -40-70 °C
- Electrical Shock Protection Class
- class I EN/IEC 61140
- Protective Treatment
- TC