Specifications

Pressure Sensor Type
pressure transmitter
Pressure Sensor Size
1 bar
Electrical Connection
1 male connector M12, 3 pins
Type Of Output Signal
analogue
Controlled Fluid
air -15-125 °C) || corrosive fluid -15-125 °C) || hydraulic oil -15-125 °C) || fresh water 0-125 °C)
Diameter
22.8 mm
Range Of Product
Telemecanique Pressure sensors XM
Analogue Output Function
4...20 mA, 2 wires
Quantity Per Set
set of 1
Product Or Component Type
electronic pressure sensors
Type Of Packing
individual
[Us] Rated Supply Voltage
12 V DC 8-33 V) || 24 V DC 8-33 V)
Pressure Sensor Name
XMLG
Fluid Connection Type
G 1/4A (male) DIN 3852-E

Contractual warranty

Warranty
18 months

Complementary

Height
58.1 mm
Surge Withstand
1 kV 42 Ohm EN/IEC 61000-4-5 || 500 kV 12 Ohm EN/IEC 61000-4-5
Response Time On Output
< 2 ms
[Uimp] Rated Impulse Withstand Voltage
0.5 kV
Repeat Accuracy
+/- 0.1 % of the measuring range
Mechanical Durability
10000000 cycles
Drift Of The Zero Point
+/- 0.015 % of measuring range/°C
Operating Position
any position
Measurement Accuracy
+/- 0.3 % of the measuring range
Protection Type
reverse polarity || load short-circuit
Electrical Circuit Type
control circuit
Drift Of The Sensitivity
+/- 0.015 % of measuring range/°C
Maximum Permissible Accidental Pressure
2.7 bar
Materials In Contact With Fluid
stainless steel type AISI 303 || ceramic || FPM (Viton)
Length
48.5 mm
Destruction Pressure
3 bar
Local Display
without
Net Weight
0.095 kg
Current Consumption
< 20 mA
Pressure Setting Range
0-1 bar

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
UL 508 || CSA C22.2 No 14 || EAC
Resistance To Conducted Disturbances
30 V 0.15-80 Hz)EN/IEC 61000-4-6
Ambient Air Temperature For Operation
-15-85 °C
Resistance To Electromagnetic Fields
200 V/m 80-1000 Hz EN/IEC 61000-4-3
Nema Degree Of Protection
NEMA 4
Ambient Air Temperature For Storage
-40-85 °C
Standards
CE || EN/IEC 61326-2-3
Resistance To Electrostatic Discharge
15 kV in air EN/IEC 61000-4-2 || 8 kV on contact EN/IEC 61000-4-2
Shock Resistance
25 gn 11 ms EN/IEC 60068-2-27
Resistance To Magnetic Fields
30 A/m 50 Hz EN/IEC 61000-4-8
Vibration Resistance
20 gn 9-2000 Hz)EN/IEC 60028-2-6
Protective Treatment
TC
Resistance To Fast Transients
4 kV EN/IEC 61000-4-4
Ip Degree Of Protection
IP66 conforming to EN/IEC 60529 || IP67 conforming to EN/IEC 60529