1 / 1
thumbnail

Descripción

Activo maduro
This product is part of the XML range, an offer of pressure sensors and switches. This pressure switch controls or regulates pressure levels in fresh water, hydraulic systems and corrosive fluids. It transforms the pressure change into a digital electrical signal when the preset operating points are reached. These pressure switches are used for pressure control or monitoring on water pumps, compressors, molding presses, injection molders, grinding machines, machining centers, etc. A pressure transmitter transforms measured pressure into a proportional analog output. The range of this transmitter is 0psi to 14.5psi and the current output is 4mA to 20mA. The transmitter accepts 12VDC to 24VDC power. The transmitter has an M12 3-pin male connector and a 1/4in NPT male fluid connection. It is compliant with IEC, CE, EAC, UL, and CSA standards and IP66, IP67, and NEMA 4 rated. It is suitable for monitoring air, fresh water, hydraulic oils and refrigeration fluids. This product is certified by CSA C22.2 No 14, EAC and UL 508. It meets CE and EN/IEC 61326-2-3 standards. One of the most comprehensive catalogues of industrial and power pressure sensors on the market. The line of XM Pressure Sensors and Switches (formerly known as OsiSense) combine the latest pressure sensing technology with adaptability to virtually any configuration.
Country of Origin
CH
Part Number
XMLG001D23
Tariff Code
9026208000
EAN
39122210
UNSPSC
39122210
Métodos de pago:
Mejor oferta de:
DEProveedor de confianza de Automa.Net
Disponibilidad:
1 pieza
En stock
Actualizado en: 08-11-2024
Garantía:
12 meses
Entrega Estimada:
Bajo pedido
Condición:
Nuevos excedentes
Nuevos excedentes - Un artículo nuevo, sin usar, sin daños y sin garantía del fabricante. El artículo puede venir sin embalaje original o en embalaje de reemplazo. Si se proporciona, es posible que la caja haya sido abierta.
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía

Specifications

Pressure Sensor Type
pressure transmitter
Pressure Sensor Size
1 bar
Electrical Connection
1 male connector M12, 3 pins
Type Of Output Signal
analogue
Controlled Fluid
air -15-125 °C) || corrosive fluid -15-125 °C) || hydraulic oil -15-125 °C) || fresh water 0-125 °C)
Diameter
22.8 mm
Range Of Product
Telemecanique Pressure sensors XM
Analogue Output Function
4...20 mA, 2 wires
Quantity Per Set
set of 1
Product Or Component Type
electronic pressure sensors
Type Of Packing
individual
[Us] Rated Supply Voltage
12 V DC 8-33 V) || 24 V DC 8-33 V)
Pressure Sensor Name
XMLG
Fluid Connection Type
1/4" - 18 NPT (male)

Contractual warranty

Warranty
18 months

Complementary

Height
58.1 mm
Surge Withstand
1 kV 42 Ohm EN/IEC 61000-4-5 || 500 kV 12 Ohm EN/IEC 61000-4-5
Response Time On Output
< 2 ms
[Uimp] Rated Impulse Withstand Voltage
0.5 kV
Repeat Accuracy
+/- 0.1 % of the measuring range
Mechanical Durability
10000000 cycles
Drift Of The Zero Point
+/- 0.015 % of measuring range/°C
Operating Position
any position
Measurement Accuracy
+/- 0.3 % of the measuring range
Protection Type
load short-circuit || reverse polarity
Electrical Circuit Type
control circuit
Drift Of The Sensitivity
+/- 0.015 % of measuring range/°C
Maximum Permissible Accidental Pressure
2.7 bar
Materials In Contact With Fluid
stainless steel type AISI 303 || FPM (Viton) || ceramic
Length
48.5 mm
Destruction Pressure
3 bar
Local Display
without
Net Weight
0.095 kg
Current Consumption
< 20 mA
Pressure Setting Range
0-1 bar

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
EAC || UL 508 || CSA C22.2 No 14
Resistance To Conducted Disturbances
30 V 0.15-80 Hz)EN/IEC 61000-4-6
Ambient Air Temperature For Operation
-15-85 °C
Resistance To Electromagnetic Fields
200 V/m 80-1000 Hz EN/IEC 61000-4-3
Nema Degree Of Protection
NEMA 4
Ambient Air Temperature For Storage
-40-85 °C
Standards
CE || EN/IEC 61326-2-3
Resistance To Electrostatic Discharge
15 kV in air EN/IEC 61000-4-2 || 8 kV on contact EN/IEC 61000-4-2
Shock Resistance
25 gn 11 ms EN/IEC 60068-2-27
Resistance To Magnetic Fields
30 A/m 50 Hz EN/IEC 61000-4-8
Vibration Resistance
20 gn 9-2000 Hz)EN/IEC 60028-2-6
Protective Treatment
TC
Resistance To Fast Transients
4 kV EN/IEC 61000-4-4
Ip Degree Of Protection
IP66 conforming to EN/IEC 60529 || IP67 conforming to EN/IEC 60529

Documentos

Data Sheet