Activo maduro
This product is part of the XM range, an offer of electronic pressure sensors. The electronic pressure sensor features a G1/4A (male) for fluid connection. It is a pressure switch with a pressure setting range of 0bar to 10bar, a maximum permissible accidental pressure of 20bar and a destruction pressure of 30bar. It supports 4mA to 20mA, 2-wire analogue output signal. It is furnished with 4-pin male connector for electrical connection. It is an electronic pressure sensor with a rated supply voltage of 24V DC (voltage limits 8V to 33V) and a current consumption of <20mA. Its dimensions are 36mm (diameter) x 67.5mm (length). It weighs 0.11kg. It is suitable for monitoring air, fresh water, hydraulic oils and refrigeration fluids. This product is certified by CSA C22.2 No 14, EAC, RCM and UL 508. It meets CE and EN/IEC 61326-2-3 standards. It is sold in sets of 25. One of the most comprehensive catalogues of industrial and power pressure sensors on the market. The line of XM Pressure Sensors and Switches (formerly known as OsiSense) combine the latest pressure sensing technology with adaptability to virtually any configuration.
Country of Origin
CH
Part Number
XMLK010B2C21TQ
Tariff Code
90262020
EAN
3389119048415
UNSPSC
39122210
Métodos de pago:
Mejor oferta de:
DEProveedor de confianza de Automa.Net
Disponibilidad:
1 pieza
En stock
Actualizado en: 08-11-2024
Garantía:
12 meses
Entrega Estimada:
Bajo pedido
Condición:
Nuevos excedentes
Nuevos excedentes - Un artículo nuevo, sin usar, sin daños y sin garantía del fabricante. El artículo puede venir sin embalaje original o en embalaje de reemplazo. Si se proporciona, es posible que la caja haya sido abierta.
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía

Specifications

Pressure Sensor Type
pressure transmitter
Type Of Output Signal
analogue
Range Of Product
Telemecanique Pressure sensors XM
Electrical Connection
1 male connector EN 175301-803-A (ex DIN43650) 4 pins
Pressure Sensor Size
10-10 bar
Product Or Component Type
electronic pressure sensors
Type Of Packing
group
Local Display
without
Pressure Sensor Name
XMLK
Current Consumption
< 20 mA
Fluid Connection Type
G 1/4A (male) DIN 3852-E
Analogue Output Function
4...20 mA, 2-wire
Controlled Fluid
air 0-80 °C) || fresh water 0-80 °C)
Quantity Per Set
set of 25
Electrical Circuit Type
control circuit
[Us] Rated Supply Voltage
24 V DC SELV 8-33 V)

Contractual warranty

Warranty
18 months

Complementary

Accuracy
0.1 % of the measuring range
Diameter
36 mm
[Uimp] Rated Impulse Withstand Voltage
0.5 kV
Repeat Accuracy
+/- 1 % of the measuring range
Drift Of The Zero Point
+/- 0.03 % of measuring range/°K
Electromagnetic Compatibility
electrostatic discharge immunity test EN/IEC 61000-4-2 8 kV air, 6 kV contact || susceptibility to electromagnetic fields EN/IEC 61000-4-3 10 V/m 80...1000 MHz || electrical fast transient/burst immunity test EN/IEC 61000-4-4 2 kV || 1.2/50 µs shock waves immunity test EN/IEC 61000-4-5 500 V 12 Ohm, 1 kV 42 Ohm || radiated RF fields EN/IEC 61000-4-6 10 V 0.15...80 MHz || immunity to magnetic fields EN/IEC 61000-4-8 30 A/m 50 Hz
Materials In Contact With Fluid
ceramic || nitrile (NBR) || stainless steel type AISI 303
Length
67.5 mm
Net Weight
0.11 kg
Mechanical Durability
10000000 cycles
Operating Position
any position
Measurement Accuracy
+/- 1 % of the measuring range
Protection Type
load short-circuit || reverse polarity
Drift Of The Sensitivity
+/- 0.04 % of measuring range/°K
Maximum Permissible Accidental Pressure
20 bar
Destruction Pressure
30 bar
Response Time On Output
< 5 ms
Pressure Setting Range
0-10 bar

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
UL 508 || EAC || RCM || CSA C22.2 No 14
Ambient Air Temperature For Operation
0-80 °C
Standards
EN/IEC 61326-2-3 || CE
Shock Resistance
25 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
20 gn 9-2000 Hz) EN/IEC 60068-2-6
Ip Degree Of Protection
IP65 conforming to EN/IEC 60529
Nema Degree Of Protection
NEMA 4
Ambient Air Temperature For Storage
-25-80 °C
Protective Treatment
TC