Schneider Electric

XMLP001GD21F

Electronic pressure sensors, Pressure sensors XM, transmitter 1 bar, 4...20 mA, G1/4 A male, FPM, M12
XMLP001GD21F
XMLP001GD21F
XMLP001GD21F
XMLP001GD21F
XMLP001GD21F
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:

Additional Information

Part Number
XMLP001GD21F
Tariff Code
9026204000

Specifications

Pressure Sensor Type
pressure transmitter
Type Of Output Signal
analogue
Range Of Product
Telemecanique Pressure sensors XM
Electrical Connection
1 male connector M12 4 pins
Pressure Sensor Size
1-1 bar
Product Or Component Type
electronic pressure sensors
Type Of Packing
individual
Local Display
without
Pressure Sensor Name
XMLP
Current Consumption
< 23 mA
Fluid Connection Type
G 1/4A (male) DIN 3852-E
Analogue Output Function
4...20 mA, 2-wire
Controlled Fluid
fresh water 0-125 °C) || air -15-125 °C) || gas -15-125 °C) || hydraulic oil -15-125 °C)
Quantity Per Set
set of 1
Electrical Circuit Type
control circuit
[Us] Rated Supply Voltage
12...24 V DC SELV 7-33 V)

Complementary

Accuracy
0.1 % of the measuring range
Diameter
26 mm
[Uimp] Rated Impulse Withstand Voltage
0.5 kV
Repeat Accuracy
+/- 0.25 % of the measuring range
Drift Of The Zero Point
+/- 0.02 % of measuring range/°K
Electromagnetic Compatibility
susceptibility to electromagnetic fields EN/IEC 61000-4-3 10 V/m 80...1000 MHz || radiated RF fields EN/IEC 61000-4-6 10 V 0.15...80 MHz || electrostatic discharge immunity test EN/IEC 61000-4-2 8 kV air, 4 kV contact || 1.2/50 µs shock waves immunity test EN/IEC 61000-4-5 1 kV 42 Ohm || immunity to magnetic fields EN/IEC 61000-4-8 100 A/m 50 Hz || electrical fast transient/burst immunity test EN/IEC 61000-4-4 4 kV
Materials In Contact With Fluid
fluorocarbon FPM || ceramic || stainless steel AISI 316L
Length
32.3 mm
Net Weight
0.075 kg
Mechanical Durability
10000000 cycles
Operating Position
any position
Measurement Accuracy
+/- 0.5 % of the measuring range
Protection Type
load short-circuit || reverse polarity
Drift Of The Sensitivity
+/- 0.02 % of measuring range/°K
Maximum Permissible Accidental Pressure
3 bar
Destruction Pressure
5 bar
Response Time On Output
<= 2 ms 10...90 % of full scale
Pressure Setting Range
0-1 bar

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1511013EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
cULus || EAC || CE || RCM
Ambient Air Temperature For Operation
-30-85 °C
Standards
NSF ANSI 61 || EN/IEC 61326-2-3
Shock Resistance
100 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
20 gn 10-2000 Hz) EN/IEC 60068-2-6
Ip Degree Of Protection
IP65 conforming to EN/IEC 60529 || IP67 conforming to EN/IEC 60529 || IP69K conforming to DIN 40050
Ambient Air Temperature For Storage
-50-100 °C