Schneider Electric
XPSAXE5120C
module XPSAXE - stop and switch monitoring - 24 V DC/AC
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
595,10 zł
1
Formas de pago:
Condiciones del producto:
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
€106.25
Additional Information
- Part Number
- XPSAXE5120C
- UNSPSC
- 32151802
- Tariff Code
- 8537109170
- Country of Origin
- DE
Specifications
- [Us] Rated Supply Voltage
- 24 V DC - 15...10 % || 24 V AC
- Range Of Product
- Preventa Safety automation
- Product Or Component Type
- Preventa safety module
- Safety Module Name
- XPSAXE
- Output Type
- relay instantaneous opening, 3 NO, volt-free
- Connections - Terminals
- spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable end || spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable end || spring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel || spring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel || spring terminals, removable terminal block, 2 x 0.5...2 x 1 mm² flexible with cable end, with double bezel || spring terminals, removable terminal block
- Number Of Additional Circuits
- 1 NC
- Safety Module Application
- for emergency stop and switch monitoring
- Safety Reliability Data
- DC > 99 % EN/ISO 13849-1 || MTTFd = 457 years EN/ISO 13849-1 || PFHd = 3E-8 1/h EN/IEC 62061
- Safety Level
- can reach PL e/category 4 EN/ISO 13849-1 || can reach SILCL 3 EN/IEC 62061
Contractual warranty
- Warranty
- 18 months
Complementary
- [Uc] Control Circuit Voltage
- 24 V DC
- Mounting Support
- 35 mm symmetrical DIN rail
- Output Thermal Current
- 6 A instantaneous and time delay outputs
- Minimum Output Voltage
- 17 V relay output
- Minimum Output Current
- 10 mA relay output
- Associated Fuse Rating
- 6 A gG instantaneous outputs
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV III IEC 60947-5-1 || 4 kV III DIN VDE 0110 part 1
- Net Weight
- 0.229 kg
- [Ui] Rated Insulation Voltage
- 300 V 2)IEC 60947-5-1 || 300 V 2)DIN VDE 0110 part 1
- Local Signalling
- 2 LEDs
- Synchronisation Time Between Inputs
- < 0.5 s
- Breaking Capacity
- 1.5 A 24 V DC-13)50 ms relay output
- Maximum Power Consumption In Va
- 4 VA DC
- Supply Frequency
- 50/60 Hz
- Maximum Response Time On Input Open
- 80 ms
- Breaking Capacity
- 3600 VA inrush AC-15 B300 relay output || 360 VA holding AC-15 B300 relay output
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1406024EN
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI1406024EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- BG || CSA || UL
- Ambient Air Temperature For Operation
- -25-55 °C
- Standards
- EN/ISO 13850 || EN 1088/ISO 14119 || EN/IEC 60204-1 || EN/IEC 60947-5-1
- Ip Degree Of Protection
- IP20EN/IEC 60529 || IP40EN/IEC 60529
- Ambient Air Temperature For Storage
- -25-75 °C