Schneider Electric
XPSPVK1184
module XPSPV - double-bodied solenoid valves - 24 V DC
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
1
Formas de pago:
Condiciones del producto:
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
€357.31
Additional Information
- Part Number
- XPSPVK1184
- UNSPSC
- 32151703
- Tariff Code
- 8537109170
- Country of Origin
- ID
Environment
- Product Certifications
- UL || TÜV || CSA
- Ambient Air Temperature For Operation
- -10-55 °C
- Standards
- IEC 60947-5-1 || IEC 692 || IEC 60204-1
- Ip Degree Of Protection
- IP10 terminals)IEC 60529 || IP40 enclosure)IEC 60529
- Ambient Air Temperature For Storage
- -25-85 °C
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1408008EN
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI1408008EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Complementary
- Height
- 73 mm
- Mounting Support
- 35 mm symmetrical DIN rail
- Power Consumption In W
- 9 W
- Minimum Output Voltage
- 17 V relay output
- Minimum Output Current
- 10 mA relay output
- [Ith] Conventional Free Air Thermal Current
- 2.5 A
- Associated Fuse Rating
- 4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1
- Net Weight
- 817.2 g
- Connections - Terminals
- captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² with cable end || captive screw clamp terminals, 2 x 2.5 mm² without cable end
- [Ui] Rated Insulation Voltage
- 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1
- Local Signalling
- 8 LEDs
- Number Of Terminal Blocks
- 32
- Enclosure Material
- polycarbonate
- Width
- 152 mm
- Depth
- 118 mm
- Breaking Capacity
- 10 mA 48 V solid state output circuit || 20 mA 24 V solid state output circuit || 1.5 A 24 V DC-13)50 ms relay output
- Maximum Response Time On Input Open
- 40 ms
- Breaking Capacity
- 180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output
Specifications
- [Us] Rated Supply Voltage
- 24 V DC - 10...10 %
- Range Of Product
- Preventa Safety automation
- Product Or Component Type
- Preventa safety module
- Enclosure Type
- removable
- Safety Module Name
- XPSPVK
- Number Of Additional Circuits
- 4 solid state outputs
- Output Type
- relay, 1 NO transfer function + 1 NC feedback loop, volt-free
- Safety Module Application
- for dynamic monitoring of double-bodied solenoid valves
- Safety Reliability Data
- MTTFd = 90.2 years ISO 13849-1 || DC = 0...99 % ISO 13849-1 || PFHd = 1.25E-8 1/h IEC 62061
- Function Of Module
- dynamic monitoring of double-bodied solenoid valves
- Safety Level
- can reach PL e/category 4 ISO 13849-1 || can reach SILCL 3 IEC 62061