safety module, Harmony XPSU, Cat 1, potential free 2 NC, NO NC, 2 PNP, 24V AC or DC, screw
XPSUAB11CP
XPSUAB11CP
XPSUAB11CP
XPSUAB11CP
XPSUAB11CP
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
608,00 zł
1
Formas de pago:
Un total de 176 Parts In-Stock de 22 Distributors
Oferta con plazo de entrega del fabricante
Entrega:1 - 2 días laborables
El mejor precio:
€45.62

Additional Information

Part Number
XPSUAB11CP
UNSPSC
32151705
Tariff Code
8536410060
Country of Origin
ID

Complementary

Number Of Outputs
2 on/off configurable pulsed output
Ambient Air Temperature For Operation
-25-55 °C
Height
100 mm
Mounting Support
35 mm symmetrical DIN rail
Minimum Output Voltage
15 V relay output
Minimum Output Current
10 mA relay output
[Ith] Conventional Free Air Thermal Current
3 A
Input/Output Type
semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
Associated Fuse Rating
6 A gG relay output IEC 60947-1
[Uimp] Rated Impulse Withstand Voltage
4 kV II IEC 60947-1
Net Weight
0.200 kg
Type Of Start
automatic/manual/monitored
Number Of Inputs
1 safety input 24 V DC 5
Input Compatibility
normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || two-hand control EN 574/ISO 13851-III A || 3-wire proximity sensors PNP
Power Consumption In Va
3.5 VA 24 V AC 50/60 Hz
[Ie] Rated Operational Current
5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally closed relay contact || 2 A DC-1 for normally closed relay contact || 1 A DC-13 for normally closed relay contact
Auxiliary Contact Composition
1 C/O
[Ui] Rated Insulation Voltage
250 V 2)IEC 60947-1
Power Consumption In W
1.5 W 24 V DC
Maximum Line Resistance
500 Ohm
Local Signalling
for power ON LED (green) || for error LED (red) || for start LED (yellow) || for safety status LED (yellow) || for safety input S12 LED (yellow) || for safety input S13 LED (yellow)
Input Protection Type
internal, electronic
Width
22.5 mm
Depth
120 mm
Synchronisation Time Between Inputs
0.5 s || 2.2 s
Maximum Response Time On Input Open
20 ms

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1811003EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1811003EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
TÜV || cULus
Ip Degree Of Protection
IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
Standards
IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional safety standard || IEC 61508-7 functional safety standard || ISO 13849-1 functional safety standard || IEC 62061 functional safety standard
Relative Humidity
5-95 % non-condensing

Specifications

[Us] Rated Supply Voltage
24 V AC - 15...10 % || 24 V DC - 20...20 %
Range Of Product
Harmony Safety Automation
Product Or Component Type
safety module
Safety Module Name
XPSUAB
Connections - Terminals
removable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel || removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
Safety Module Application
for electrical monitoring of two-hand control stations || for application with safety switchover contact || for emergency stop, guard and light curtain monitoring || monitoring antivalent contacts
Safety Reliability Data
MTTFd >= 30 years ISO 13849-1 || Dcavg < 60 % ISO 13849-1 || PFHd = 1177E-09 1/h ISO 13849-1 || HFT = 0 IEC 62061 || PFHd = 1177E-09 1/h IEC 62061 || SFF > 60% IEC 62061 || HFT=0 IEC 61508-1 || PFHd = 1177E-09 1/h IEC 61508-1 || SFF > 60% IEC 61508-1 || type = B IEC 61508-1
Electrical Circuit Type
NC pair || PNP pair || antivalent pair || OSSD pair
Function Of Module
emergency stop monitoring 1-channel wiring || guard monitoring 1-channel wiring || monitoring 1 PNP sensor || monitoring two-hand control station type IIIA || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE) || proximity sensor monitoring
Safety Level
can reach PL c/category 1 ISO 13849-1 || can reach SILCL 1 IEC 62061 || can reach SIL 1 IEC 61508