Schneider Electric

XUSL2E30H076NWH

1 / 1
thumbnail

Descripción

Activo maduro
Country of Origin
IT
Part Number
XUSL2E30H076NWH
Tariff Code
85365019
EAN
3389119619912
UNSPSC
46171620
Métodos de pago:
Mejor oferta de:
SKProveedor de confianza de Automa.Net
Disponibilidad:
10 piezas
En stock
Actualizado en: 08-11-2024
Garantía:
12 meses
Entrega Estimada:
Bajo pedido
Condición:
Nuevo Precintado de Fábrica
Nuevo Precintado de Fábrica - Un artículo completamente nuevo, sin usar, sin abrir, sin daños, en su embalaje original sellado por el fabricante.
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía

Specifications

Minimum Object Diameter For Detection
30 mm
Range Of Product
Telemecanique Safety light curtains XUSL
Height Protected
760 mm
Control Type
selected by wiring
Product Specific Application
for hand protection
Number Of Beams
38
Product Or Component Type
safety light curtain type 2
[Sn] Nominal Sensing Distance
3-10 m by cabling || 0-3 m by cabling
Output Type
2 safety outputs OSSD solid-state PNP arc suppression)
Device Short Name
XUSL2E
Type Of Start
manual || automatic

Contractual warranty

Warranty
18 months

Complementary

Electrical Connection
1 male connector M12 5 pins transmitter || 1 male connector M12 8 pins receiver
Function Available
test || muting through external safety module XPSLCMUT1160 || LED display of operating modes and faults || anti-condensation system
Current Consumption
42 mA no-load transmitter || 83 mA no-load receiver || 42 mA transmitter || 900 mA with maximum load receiver
Housing Colour
red RAL 3000
Maximum Power
10 W
Offer Type
standard distance
Fixing Mode
by fixing brackets
Material
PMMA (polymethyl methacrylate) tube || stainless steel AISI 316L sealing plug || PVC (polyvinyl chloride) Cable
[Ie] Rated Operational Current
2 A
Kit Composition
adjustable mounting bracket(s) || 1 receiver(s) || 1 transmitter(s) || 1 user guide with certificate of conformity on CD-ROM || silicone o-ring(s) || 1 PVC cable(s)
Type Of Cable
unshielded cable AWG 22 10-10 m
Emission
IR LED 950 nm
Output Voltage
24 V
Detection System
transmitter-receiver system
Provided Equipment
with heating system
Ohmic Cable Resistance
55.31 mOhm
Response Time
11 ms
Maximum Voltage Drop
<0.5 V
Marking
CE
Output Current Limits
0.4 A safety outputs OSSD
Supply
power supply IEC 61496-1 || power supply IEC 60204-1
Output Circuit Type
DC
[Eaa] Effective Aperture Angle
5 ° at 3 m
Net Weight
5.05 kg
Local Signalling
1 multi-colour LED transmitter || 2 dual colour LEDs receiver
[Us] Rated Supply Voltage
24 V DC +/- 20 %

Offer Sustainability

Circularity Profile
ENVEOLI1406015EN
Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1406015EN
Sustainable Offer Status
Green Premium product
Toxic Heavy Metal Free
Yes
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes

Environment

Product Certifications
Ecolab || cULus || CE || TÜV
Ambient Air Temperature For Operation
-30-55 °C || -13-131 °F
Directives
98/37/EEC - machinery || 89/655/EEC - work equipment || 89/336/EEC - electromagnetic compatibility
Ambient Air Temperature For Storage
-30-70 °C || -13-158 °F
Service Life
20 year(s)
Relative Humidity
0-95 % without condensation
Safety Reliability Data
PFHd = 4.57E-8 1/h IEC 61508
Shock Resistance
10 gn 16 ms IEC 61496-1
Environmental Characteristic
resistance to light disturbance EN/IEC 61496-2
Vibration Resistance
0.35 +/- 0.05 mm 10-55 Hz)IEC 61496-1
Ip Degree Of Protection
IP69K
Safety Level
type 2 IEC 61496-1 || category 2 EN/ISO 13849-1 || SIL 1 IEC 61508 || SILCL 1 IEC 62061 || PL = c EN/ISO 13849-1