Schneider Electric

XUYAFLCO966S

Photoelectric sensors XU, XUY, ampli for fibre, illumination, 12...24 VDC, M8
XUYAFLCO966S
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:

Additional Information

Part Number
XUYAFLCO966S
UNSPSC
39121528
Tariff Code
8541498000
Country of Origin
FR

Specifications

Series Name
Application assembly
Type Of Output Signal
discrete
Range Of Product
Telemecanique Photoelectric sensors XU
Product Specific Application
verifying operation of indicator lights on electrical appliances || testing car headlights on production line
Detection System
diffuse
Sensor Design
fiber design
Electronic Sensor Type
photo-electric sensor
Sensor Name
XUY
[Sn] Nominal Sensing Distance
0-0 mm depending on plastic fibres diameter 2.2 mm used
Material
plastic
Wiring Technique
4-wire

Contractual warranty

Warranty
18 months

Complementary

Current Consumption
< 40 mA
Electrical Connection
1 male connector M8, 4 pins
Discrete Output Function
1 NO or 1 NC programmable
Switching Frequency
< 5 Hz
Status Led
output signal 1 LED green) || limit of detection 1 LED red) || time delay active 1 LED red)
Setting-Up
with sensitivity adjustment
Supply Voltage Limits
10-30 V DC
Maximum Voltage Drop
<2 V closed state)
Maximum Delay Recovery
100 ms
Switching Capacity In Ma
100 mA overload and short-circuit protection)
Enclosure Material
polycarbonate
Supply Circuit Type
DC
Output Type
solid state
Maximum Delay Response
100 ms
Net Weight
0.054 kg
Voltage State 0 Guaranteed
< 1.4 V
[Us] Rated Supply Voltage
24 V DC reverse polarity protection
Voltage State 1 Guaranteed
> 3 V
Time Delay Range
0...5 s adjustment increments

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
CE
Ambient Air Temperature For Operation
0-60 °C
Ambient Air Temperature For Storage
-20-80 °C
Ip Degree Of Protection
IP65 IEC 60529