Weidmuller

0139160000

SAK 70/35
0139160000
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
£1,642.77
1
Formas de pago:
Un total de 29 Parts In-Stock de 9 Distributors

Additional Information

Part Number
0139160000

Approvals

Approvals
CE, CSA, DNV GL, EAC, MARITREG, UR
ROHS
Conform
UL File Number Search
E60693

Dimensions And Weights

Width
22 mm
Width (inches)
0.866 inch
Height
75 mm
Height (inches)
2.953 inch
Depth
87 mm
Depth (inches)
3.425 inch
Net weight
156.1 g

Dimensions

TS 35 offset
19.5 mm

Csa Rating Data

Certificate No. (CSA)
12400-136
Current size C (CSA)
150 A
Voltage size C (CSA)
600 V
Wire cross section max. (CSA)
00 AWG
Wire cross section min. (CSA)
4 AWG

Additional Technical Data

Explosion-tested version
No
Number of similar terminals
1
Open sides
right
Type of mounting
Clamped

Material Data

Material
PA 66
Colour
beige / yellow
UL 94 flammability rating
V-2

Safety Note

Safety notice
Safety Information

Classifications

ETIM 6.0
EC000897
ETIM 7.0
EC000897
EClass 9.0
27-14-11-20
EClass 9.1
27-14-11-20
EClass 10.0
27-14-11-20
UNSPSC
30-21-18-11

System Specifications

Version
Screw connection, for screwable cross-connection, One end without connector
End cover plate required
Yes
Number of potentials
1
Number of levels
1
Number of clamping points per level
2
Number of potentials per tier
1
Levels cross-connected internally
No
PE connection
No
Rail
TS 35
N-function
No
PE function
No
PEN function
No

Temperatures

Storage temperature, max.
40 °C
Storage temperature, min.
10 °C
Storage temperature
10 °C...40 °C
Continuous operating temp., min.
-50 °C
Continuous operating temp., max.
100 °C

Conductors For Clamping (Additional Connection)

Conductor cross-section, flexible plus plastic collar DIN 46228/1, further connection, max.
35 mm²

Rating Data

Rated cross-section
70 mm²
Rated voltage
1,000 V
Rated current
192 A
Current at maximum wires
192 A
Standards
IEC 60947-7-1
Volume resistance according to IEC 60947-7-x
0.17 mΩ
Power loss in accordance with IEC 60947-7-x
6.14 W
Rated impulse withstand voltage
8 kV
Pollution severity
3

Conductors For Clamping (Rated Connection)

Blade size
S6 (DIN 6911)
Clamping range, max.
70 mm²
Clamping range, min.
16 mm²
Clamping screw
M 8
Connection cross-section, stranded, max.
70 mm²
Connection cross-section, stranded, min.
16 mm²
Connection direction
on side
Gauge to IEC 60947-1
B11
Number of connections
2
Stripping length
24 mm
Tightening torque, max.
12 Nm
Tightening torque, min.
6 Nm
Type of connection
Screw connection
Wire connection cross section AWG, max.
AWG 2/0
Wire connection cross section AWG, min.
AWG 4
Wire connection cross section, finely stranded, max.
70 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.
35 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.
16 mm²
Wire connection cross-section, finely stranded, min.
16 mm²
Wire connection cross-section, solid core, max.
16 mm²
Wire connection cross-section, solid core, min.
16 mm²

Ul Rating Data

Certificate No. (UR)
E60693
Conductor size Factory wiring max. (UR)
00 AWG
Conductor size Factory wiring min. (UR)
4 AWG
Conductor size Field wiring max. (UR)
00 AWG
Conductor size Field wiring min. (UR)
4 AWG
Current size C (UR)
150 A
Voltage size C (UR)
600 V