BMI0702T06F
- Nuovo sigillato in fabbrica10 pz.
- Nuove eccedenze2 pz.
#1 Conferenza per il commercio di automazione industriale| 16-18 giugno 2025| Hilton Warsaw City, Varsavia, PoloniaScopri di più
Categorie
Torna a:Tutte le categorieFiltri
SIRIUS soft starter 200-690 V 171 A, 110-250 V AC spring-type terminals
SIRIUS soft starter 200-690 V 171 A, 110-250 V AC spring-type terminals
SIRIUS SOFT STARTER, S2 72A, 37KW/400V 40 DEGR. AC 200-480V, AC/DC110-230V, Screw Terminals
SIRIUS SOFT STARTER, S2 72A, 37KW/400V 40 DEGR. AC 200-480V, AC/DC110-230V, Screw Terminals
SIRIUS SOFT STARTER, S2 80A, 45KW/400V 40 DEGR. AC 200-480V, AC/DC110-230V, Screw Terminals
SIRIUS SOFT STARTER, S2 80A, 45KW/400V 40 DEGR. AC 200-480V, AC/DC110-230V, Screw Terminals
TeSys U control and diagnostic unit to be inserted in advanced power bases LUB120, LUB320, LUB380 to form a TeSys U starter controller, for 3-phase motor applications up to 0.25kW@400V. It provides full protection to motors with a rated current Ir 0.35-1.4A (Ir adjustable), overload tripping class 20, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). For diagnostics, it provides a thermal overload alarm to be managed with an additional function module (to be ordered separately) and a test push button for overload simulation. To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
TeSys U control and diagnostic unit to be inserted in advanced power bases LUB120, LUB320, LUB380 to form a TeSys U starter controller, for 3-phase motor applications up to 0.25kW@400V. It provides full protection to motors with a rated current Ir 0.35-1.4A (Ir adjustable), overload tripping class 20, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). For diagnostics, it provides a thermal overload alarm to be managed with an additional function module (to be ordered separately) and a test push button for overload simulation. To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Load feeder fuseless direct start, AC 400V, sz s00 0.9. . .1.25a, DC 24v screw connection for busbar systems 60mm type of coordination 2, iq = 150ka (also fulfills type of coordination 1) 1NO (contactor)
Load feeder fuseless direct start, AC 400V, sz s00 0.9. . .1.25a, DC 24v screw connection for busbar systems 60mm type of coordination 2, iq = 150ka (also fulfills type of coordination 1) 1NO (contactor)
SIRIUS soft starter 200-600 V 210 A. 24 V AC/DC Spring-loaded terminals Thermistor input
SIRIUS soft starter 200-600 V 210 A. 24 V AC/DC Spring-loaded terminals Thermistor input
SIRIUS soft starter 200-600 V 171 A. 24 V AC/DC spring-type terminals Thermistor input
SIRIUS soft starter 200-600 V 171 A. 24 V AC/DC spring-type terminals Thermistor input
SIRIUS soft starter 200-600 V 370 A. 24 V AC/DC spring-type terminals Analog output
SIRIUS soft starter 200-600 V 370 A. 24 V AC/DC spring-type terminals Analog output
SIRIUS soft starter 200-480 V 113 A, 110-250 V AC spring-type terminals
SIRIUS soft starter 200-480 V 113 A, 110-250 V AC spring-type terminals
SIRIUS soft starter 200-480 V 315 A, 24 V AC/DC Screw terminals
SIRIUS soft starter 200-480 V 315 A, 24 V AC/DC Screw terminals
LOAD FEEDER FUSELESS DIRECT START, AC 400V, SZ S00 1.8. . .2.5A, AC 230V SCREW CONNECTION FOR BUSBAR SYSTEMS 60MM TYPE OF COORDINATION 2, IQ = 150KA (ALSO FULFILLS TYPE OF COORDINATION 1) 1NO (CONTACTOR)
LOAD FEEDER FUSELESS DIRECT START, AC 400V, SZ S00 1.8. . .2.5A, AC 230V SCREW CONNECTION FOR BUSBAR SYSTEMS 60MM TYPE OF COORDINATION 2, IQ = 150KA (ALSO FULFILLS TYPE OF COORDINATION 1) 1NO (CONTACTOR)