ABB
1SCA105021R1001
OT100F6 SWITCH-DISCONNECTOR
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
€77.73
1
Metodi di pagamento:
Un totale di 300 Parts In-Stock da 11 Distributors
Condizioni del prodotto:
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
€70.69
Additional Information
- Part Number
- 1SCA105021R1001
- UNSPSC
- 39122233
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Switch disconnector
- Class Code : EC000216
- Version : 7
Dimensions
- Product Net Width
- 140 mm
- Product Net Height
- 100 mm
- Product Net Depth / Length
- 86 mm
- Product Net Weight
- 1.1 kg
Technical
- Rated Operational Current AC-21A (Ie)
- (380 ... 415 V) 100 A(500 V) 100 A(690 V) 100 A
- Rated Operational Current AC-22A (Ie)
- (380 ... 415 V) 100 A(500 V) 100 A(690 V) 100 A
- Rated Operational Current AC-23A (Ie)
- (380 ... 415 V) 80 A(500 V) 60 A(690 V) 40 A
- Rated Operational Power AC-23A (Pe)
- (220 ... 240 V) 22 kW(400 ... 415 V) 37 kW(500 V) 37 kW(690 V) 37 kW
- Conventional Free-air Thermal Current (Ith)
- Θ = 40 °C 115 A
- Conventional Thermal Current (Ithe)
- Fully Enclosed 115 A
- Rated Impulse Withstand Voltage (Uimp)
- 8 kV
- Rated Insulation Voltage (Ui)
- acc. to IEC/EN 60664-1 750 V
- Rated Operational Voltage
- Main Circuit 750 V
- Rated Short-Circuit Making Capacity (Icm)
- (690 V) 3.6 kA
- Rated Short-time Withstand Current Low Voltage (Icw)
- for 1 s 2.5 kA
- Rated Conditional Short-Circuit Current (Inc)
- (125 A fuse, 415 V) 50 kA(125 A fuse, 690 V) 10 kA(63 A fuse, 690 V) 50 kA
- Power Loss
- at Rated Operating Conditions per Pole 4.0 W
- Pollution Degree
- 3
- Handle Type
- KnobHandle and shaft not included
- Switches Operating Mechanism
- Mechanism on Top of the Switch
- Distance Between Phases
- Standard
- Position of Line Terminals
- Top In - Bottom OutBottom In - Top Out
- Operating Mode
- Front operated
- Standards
- IEC 60947-3 / UL 98 / CSA C22.2 NO.4
- Special Functions
- No
- Mounting Type
- Base mounting
- Number of Poles
- 6
- Cable Cross-Section
- Cu 10 ... 70 mm²
- Degree of Protection
- Front IP20
- Terminal Type
- Screw Terminals
- Tightening Torque
- acc. IEC 60947-1 6 N·m
- Mechanical Durability
- 20000
- Lock Type
- No
Classifications
- Object Classification Code
- Q
- ETIM 9
- EC000216 - Switch disconnector (low voltage)
- IDEA Granular Category Code (IGCC)
- 5290 >> Disconnect switch
- EClass
- V11.1 : 27371403
- WEEE Category
- 5. Small Equipment (No External Dimension More Than 50 cm)
- E-Number (Finland)
- 3601405
Environmental
- RoHS Status
- Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Environmental Information
- 1SCC301264D0201
Circular Value
- Conflict Minerals Reporting Template (CMRT)
- 9AKK108467A5658
- Environmental Information
- 1SCC301264D0201
- REACH Declaration
- 1SCC011021D0201
- RoHS Information
- 1SCC011020D0201
Technical UL/CSA
- Maximum Operating Voltage UL/CSA
- 600 V
- Ampere Rating
- 100 A
- Horsepower Rating UL/CSA
- (110 ... 120 V AC) Single Phase 5 Hp(240 V AC) Single Phase 15 Hp(440 ... 480 V AC) Single Phase 25 Hp(550 ... 600 V AC) Single Phase 20 Hp(220 ... 240 V AC) Three Phase 30 Hp(440 ... 480 V AC) Three Phase 50 Hp(550 ... 600 V AC) Three Phase 50 Hp
- Tightening Torque
- acc. IEC 60947-1 6 N·m
- Tightening Torque UL/CSA
- 55 in·lb
Ordering
- Minimum Order Quantity
- 1 piece
- Customs Tariff Number
- 85365080
- Country of Origin
- Finland (FI)
Altre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro