ABB
2CSF202001R2400
F202 AC-40/0.1 Residual Current Circuit Breaker 2P AC type 100 mA
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
£21.60
1
Metodi di pagamento:
Un totale di 60 Parts In-Stock da 17 Distributors
Condizioni del prodotto:
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
€27.19
Additional Information
- Part Number
- 2CSF202001R2400
- UNSPSC
- 39121601
- ETIM
- Group Code : EG000020
- Group Description : Circuit breakers and fuses
- Class Description : Residual current circuit breaker (RCCB)
- Class Code : EC000003
- Version : 7
Installation
- Instructions and Manuals
- 9AKK107991A6127
Dimensions
- Width in Number of Modular Spacings
- 2
- Product Net Width
- 0.035 m
- Product Net Height
- 0.085 m
- Product Net Depth / Length
- 0.069 m
- Product Net Weight
- 0.200 kg
- Built-In Depth (t2)
- 69 mm
Technical
- Standards
- IEC/EN 61008UL 1053
- Type of Residual Current
- AC type
- Rated Voltage (Ur)
- 230 V
- Rated Operational Voltage
- 230 V
- Rated Insulation Voltage (Ui)
- 500 V
- Rated Impulse Withstand Voltage (Uimp)
- 4 kV
- Rated Current (In)
- 40 A
- Rated Residual Current
- 100 mA
- Rated Conditional Short-Circuit Current (Inc)
- 10 kA
- Rated Service Short-Circuit Breaking Capacity (Ics)
- 1 kA
- Maximum Surge Current
- 0.25 kA
- Leakage Current Type
- AC
- Rated Frequency (f)
- 50 … 60 Hz
- Power Loss
- at Rated Operating Conditions per Pole 2.4 W
- Power Supply Connection
- Arbitrary
- Electrical Endurance
- 10000 cycle
- Number of Poles
- 2
- Operating Characteristic
- Instantaneous
- Mounting Type
- DIN-Rail
- Options Provided
- None
- Accessories Available
- Yes
- Connecting Capacity
- Busbar 10 mm²Rigid 25 ... 25 mm²Flexible 25 ... 25 mm²
- Rated Cross-Section
- 4 - Multi-Wired 0...25 mm²1 - Solid-Core 25...25 mm²
Eco Transparency
- Environmental Product Declaration - EPD
- 9AKK108467A3700
Classifications
- ETIM 9
- EC000003 - Residual current circuit breaker (RCCB)
- EPLAN Function Definition
- Ground fault current circuit-breaker / Ground fault current circuit breakers, 4 connection points / Ground fault current circuit breaker, two-pole 1/2 2/1 3/4 4/3
- WEEE Category
- 5. Small Equipment (No External Dimension More Than 50 cm)
- WEEE B2C / B2B
- Business To Consumer
- CN8
- 85363030
- EClass
- V11.0 : 27142201
- IDEA Granular Category Code (IGCC)
- 4875 >> Residual current circuit breaker (RCCB)
- Object Classification Code
- F
Environmental
- Ambient Temperature
- -25...55 °C
- Ambient Air Temperature
- Operation -25...55 °C
- Degree of Protection
- IP2X
- Pollution Degree
- 2
- Resistance to Vibrations acc. to IEC 60068-2-6
- 0.1 mm or 1 g - 20 cycles at 5…150…5 Hz
- Resistance to Shock acc. to IEC 60068-2-27
- 25g 2 shocks 13 ms
- RoHS Status
- Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- RoHS Information
- 9AKK106713A5602
- REACH Declaration
- 9AKK108467A9482
- Environmental Information
- Refer to RoHS
- Conflict Minerals Reporting Template (CMRT)
- 9AKK108468A3363
Circular Value
- Circular Design Principles Recyclability Rate
- Design for Closing Resource Loops - Standard EN45555 - 52,5 %
- Sustainable Material Content
- 0 %
- End of Life Instructions
- 9AKK108468A4361
Technical UL/CSA
- Maximum Operating Voltage UL/CSA
- 277 V AC
- Short-Circuit Current Rating (SCCR)
- 100 mA
Ordering
- Minimum Order Quantity
- 1 piece
- Package Level 1 Units
- box 1 piece
- Package Level 1 Gross Weight
- 0.235 kg
Altre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro