ABB

ASL16-30-10-87

ASL16-30-10-87 125VDC Contactor
ASL16-30-10-87
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
Invia una richiesta di prezzo
1
Metodi di pagamento:
Richiedete un preventivo e vi invieremo informazioni su disponibilità e prezzi.

Additional Information

Part Number
ASL16-30-10-87
UNSPSC
39121529
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Power contactor, AC switching
Class Code : EC000066
Version : 7

Dimensions

Product Net Width
45 mm
Product Net Depth / Length
72.5 mm
Product Net Height
68 mm
Product Net Weight
0.28 kg

Technical

Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Standards
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
Rated Operational Voltage
Auxiliary Circuit 690 VMain Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors q = 40 °C 25 Aacc. to IEC 60947-5-1, q = 40 °C 10 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 24 A(690 V) 60 °C 20 A(690 V) 70 °C 16 A
Rated Operational Current AC-3 (Ie)
(220 / 230 / 240 V) 60 °C 15.7 A(380 / 400 V) 60 °C 15.5 A(415 V) 60 °C 15.5 A(440 V) 60 °C 13.6 A(500 V) 60 °C 12.5 A(690 V) 60 °C 9 A
Rated Operational Power AC-3 (Pe)
(220 / 230 / 240 V) 4 kW(400 V) 7.5 kW(415 V) 7.5 kW(440 V) 7.5 kW(500 V) 7.5 kW(690 V) 7.5 kW
Rated Operational Current AC-15 (Ie)
(220 / 240 V) 4 A(24 / 127 V) 6 A(400 / 440 V) 3 A(500 V) 2 A(690 V) 2 A
Rated Short-time Withstand Current (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 124 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 24 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 75 Afor 0.1 s 140 Afor 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour(AC-15) 1200 cycles per hour(AC-2 / AC-4) 300 cycles per hour(AC-3) 1200 cycles per hour(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)
(110 V) 0.55 A / 60 W(220 V) 0.27 A / 60 W(125 V) 0.55 A / 69 W(24 V) 6 A / 144 W(250 V) 0.27 A / 68 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W
Rated Insulation Voltage (Ui)
acc. to UL/CSA 600 Vacc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 Vacc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
DC Operation 125 V
Operate Time
Between Coil De-energization and NC Contact Closing 15 ... 20 msBetween Coil De-energization and NO Contact Opening 13 ... 17 msBetween Coil Energization and NC Contact Opening 31 ... 53 msBetween Coil Energization and NO Contact Closing 36 ... 59 ms
Connecting Capacity Main Circuit
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Rigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 9 mmControl Circuit 9 mmMain Circuit 9 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal Type
Screw Terminals

Container Information

Package Level 1 Units
1 piece
Package Level 1 Width
78 mm
Package Level 1 Depth / Length
80 mm
Package Level 1 Height
48 mm
Package Level 1 Gross Weight
0.28 kg
Package Level 1 EAN
3471523059672
Package Level 2 Units
40 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
195 mm
Package Level 2 Height
315 mm
Package Level 2 Gross Weight
11.2 kg
Package Level 3 Units
960 piece

Classifications

Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
IDEA Granular Category Code (IGCC)
4755 >> Contactors

Environmental

Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °CClose to Contactor Fitted with Thermal O/L Relay -25 ... +60 °CClose to Contactor without Thermal O/L Relay -40 ... +70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
3000 m
Resistance to Vibrations acc. to IEC 60068-2-6
5 ... 300 Hz 3 g Closed position / 2 g Open position
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 10 gClosed, Shock Direction: C1 20 gClosed, Shock Direction: C2 20 gOpen, Shock Direction: B1 5 gOpen, Shock Direction: C1 9 gOpen, Shock Direction: C2 14 gShock Direction: A 20 gShock Direction: B2 15 g

Technical UL/CSA

General Use Rating UL/CSA
(600 V AC) 20 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3/4 Hp(240 V AC) Single Phase 2 Hp(200 ... 208 V AC) Three Phase 3 Hp(220 ... 240 V AC) Three Phase 5 Hp(440 ... 480 V AC) Three Phase 10 Hp(550 ... 600 V AC) Three Phase 10 Hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lbControl Circuit 9 in·lbMain Circuit 9 in·lb

Ordering

Minimum Order Quantity
40 piece
Customs Tariff Number
85364900