Frequency via Jaw
- Range
- 5.0 Hz to 500.0 Hz
- Accuracy
- 0.5% ±5 digits
- Trigger level
- 5 Hz to 10 Hz, ≥10 A
- Resolution
- 0.1 Hz
- Trigger level
- 10 Hz to 100 Hz, ≥5 A
- Trigger level
- 100 Hz to 500 Hz, ≥10 A
Capacitance
- Resolution
- 1 μ F (≤ 1000 μF)
- Range
- 1000 μF
- Resolution
- 0.1 μF (≤ 100 μF)
- Accuracy
- 1% ±4 digits
DC Voltage
- Resolution
- 1 V (≤1000 V)
- Range
- 1000 V
- Resolution
- 0.1 V (≤600.0 V)
- Accuracy
- 1% ±5 digits
Frequency via Flexible Current Probe
- Range
- 5.0 Hz to 500.0 Hz
- Resolution
- 0.1 Hz
- Trigger level
- 5 Hz to 20 Hz, ≥25 A
- Trigger level
- 100 Hz to 500 Hz, ≥25 A
- Accuracy
- 0.5% ±5 digits
- Trigger level
- 20 Hz to 100 Hz, ≥20 A
mV dc
- Range
- 500.0 mV
- Resolution
- 0.1 mV
- Accuracy
- 1% ±5 digits
Mechanical Specifications
- Safety
- IEC 61010-1, Pollution Degree 2
- Operating altitude
- 3000 m
- Batteries
- 2 AA, NEDA 15A, IEC LR6
- IP rating
- IEC 60529: IP30, non-operating
- Safety
- IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V
- Storage altitude
- 12,000 m
- Flexible current probe cable length (head to electronics connector)
- 1.8 m
- Operating humidity - non-condensing (< 10°C)
- ≤90% RH (at 10 °C to 30 °C)
- Safety
- IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
- Weight
- 395 g
- Operating humidity - non-condensing (< 10°C)
- ≤75% RH (at 30 °C to 40 °C)
- Size (L x W x H)
- 249 x 85 x 45 mm
- Jaw opening
- 34 mm
- Maximum voltage between any terminal and earth ground
- 1000 V
- Storage temperature
- -40 °C to +60 °C
- Operating humidity - non-condensing (< 10°C)
- ≤45% RH (at 40 °C to 50 °C)
- Radio Frequency Certification FCC ID
- T68-FBLE IC:6627A-FBLE
- Operating temperature
- -10 °C to +50 °C
- Flexible current probe diameter
- 7.5 mm
AC Voltage
- Resolution
- 1 V (≤1000 V)
- Range
- 1000 V
- Accuracy
- 1.5% ±5 digits (20 Hz to 500 Hz)
- Resolution
- 0.1 V (≤600.0 V)
Electromagnetic Compatibility (EMC)
- International
- Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
- Korea (KCC)
- Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
- USA (FCC)
- 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
- Korea (KCC)
- Class A Equipment (Industrial Broadcasting & Communication Equipment)
- International
- Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
- Temperature coefficients
- Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
- International
- IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
- International
- CISPR 11: Group 1, Class A
AC Current via Flexible Current Probe
- Range
- 2500 A
- Resolution
- 1 A (≤ 2500 A)
- Accuracy
- 3% ±5 digits (5 – 500 Hz)
- Crest Factor (50/60Hz)
- Add 2% for C.F. > 2
- Crest Factor (50/60Hz)
- 2.5 at 1400 A
- Crest Factor (50/60Hz)
- 3.0 at 1100 A
- Crest Factor (50/60Hz)
- 1.42 at 2500 A
- Resolution
- 0.1 A (≤ 600 A)
General Specifications
- Accuracy
- 2% ±5 digits (10 Hz to 100 Hz)
- Crest Factor (50 Hz/60 Hz)
- Add 2% for C.F. >2
- Accuracy
- 2.5% ±5 digits (100-500 Hz)
- Range
- 999.9 A
- Crest Factor (50 Hz/60 Hz)
- 3 @ 500 A
- Crest Factor (50 Hz/60 Hz)
- 2.5 @ 600 A
- Resolution
- 0.1 A
Resistance
- Resolution
- 1 Ω (≤6000 Ω)
- Range
- 60 kΩ
- Resolution
- 0.1 Ω (≤600 Ω)
- Accuracy
- 1% ±5 digits
- Resolution
- 10 Ω (≤60 kΩ)
DC Current
- Accuracy
- 2% ±5 digits
- Resolution
- 0.1 A
- Range
- 600.0 A
Altre categorie
AttuatoriBlocchiCavi, tubi e tubi flessibiliCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro