Fluke
Fluke 190-502
1 / 4
- Part Number
- Fluke 190-502
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Mechanical and General Specifications
- Size
- 270 x 190 x 70 mm
- Weight
- 2.2 kg
- Warranty
- 3-years on main instrument, 1-year on accessories
- Li-Ion battery
- BP290 2400 mAh Li-ion battery up to 4 hours included standard
DMM Specification
- Meter inputs (also used as External Trigger Input for the Oscilloscope Mode)
- 4 mm banana inputs, fully isolated from scope inputs and from scope ground
- Maximum resolution
- 5000 counts
- Measurements
- VDC, VAC rms, VAC + DC rms, Resistance, Continuity, Diode Test, Current (through clamp or shunt), Temperature °C or °F (using optional converter)
- Memory
- Recording: 10
- Display
- 153 mm full color LCD with fast update rate
VPS410 Voltage Probe Sets (one red, one blue)
- Warranty
- Three years on main instrument, one year on accessories
Specifications
- Bandwidth
- 500 MHz
- Number of channels
- 500 MHz: 2 channels
- Real-time sample rate
- 5 GS
- Inputs
- 2 scope plus DMM input
- Independently floating isolated inputs
- Up to 1000 V CAT III/600 V CAT IV between inputs, references and ground
- Timebase range
- 10 ns - 2 min/div
- Input sensitivity
- 2 mV-100 V/div
- Trigger types
- Connect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle
- Trigger source
- Any scope input channel, or external via DMM input
- Glitch capture
- 8 ns
- Scope measurements
- Automatic: 30
- Maximum record length
- Scope mode: 10,000 pts per input
- Persistence
- Digital persistence giving analog oscilloscope-like waveform decay
- Waveform compare
- Waveform reference with automatic Pass/Fail testing
Safety Specifications
- Electrical safety
- 1,000 V CAT III/600V CAT IV (EN61010-1)
Environmental Specifications
- Operating temperature
- 0 °C to 50 °C Excluding Batteries
- Storage temperature
- -20 °C to +60 °C
- Operating altitude
- Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Documenti
Data Sheet
ScaricareAltre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro