Fluke
Fluke 87V/E2 Kit
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Un totale di 2 Parts In-Stock da 1 Distributor
Condizioni del prodotto:
Additional Information
- Part Number
- Fluke 87V/E2 Kit
Specifications
- Voltage DC
- Maximum Voltage: 1000 V
- Voltage DC Accuracy
- ±(0.05% + 1)
- Voltage DC Maximum Resolution
- 10 µV
- Voltage AC
- Maximum Voltage: 1000 V
- Voltage AC Accuracy
- ±(0.7% + 2) True RMS
- Voltage AC AC Bandwidth
- 20 kHz with low pass filter; 3 db @ 1 kHz
- Voltage AC Maximum Resolution
- 0.1 mV
- Current DC Maximum Amps
- 10 A (20 A for 30 seconds maximum)
- Current DC Amps Accuracy
- ±(0.2% + 2)
- Current DC Maximum Resolution
- 0.01 µA
- Current AC Maximum Amps
- 10 A (20 A for 30 seconds maximum)
- Current AC Amps Accuracy
- ±(1.0% + 2) True RMS
- Current AC Maximum Resolution
- 0.1 µA
- Resistance Maximum Resistance
- 50 MΩ
- Resistance Accuracy
- ±(0.2% + 1)
- Resistance Maximum Resolution
- 0.1Ω
- Capacitance Maximum Capacitance
- 9,999 µF
- Capacitance Accuracy
- ±(1% + 2)
- Capacitance Maximum Resolution
- 0.01 nF
- Frequency Maximum Frequency
- 200 kHz
- Frequency Accuracy
- ±(0.005% + 1)
- Frequency Maximum Resolution
- 0.01 Hz
- Duty Cycle Maximum Duty Cycle
- 99.9%
- Duty Cycle Accuracy
- ±(0.2% per khz +0.1%)
- Duty Cycle Maximum Resolution
- 0.1%
- Temperature Measurement
- -200.0°C - 1090°C-328.0°F - 1994.0°Fexcluding probe
- 80 BK Temperature Probe
- -40.0°C - 260°C-40.0°F - 500°F, 2.2°C or 2% whichever is greater
- Conductance Maximum Conductance
- 60.00 nS
- Conductance Accuracy
- ±(1.0% + 10)
- Conductance Maximum Resolution
- 0.01 nS
- Diode Range
- 3 V
- Diode Resolution
- 1 mV
- Diode Accuracy
- ±(2% + 1)
- Duty Cycle Range Accuracy
- Within ±(02% per kHz +0.1%)
Mechanical and General Specifications
- Size
- 201 x 98 x 52 mm (with holster)
- Weight
- 355 g624 g - with holster
- Display Digital
- 6000 counts updates 4/sec.19,999 counts in high-resolution mode
- Display Analog
- 32 segments, updates 40/sec.
- Display Frequency
- 19,999 counts, updates 3/sec at > 10 Hz
- Warranty
- Lifetime
- Battery Life
- Alkaline: ~400 hours typical, without backlight
- Shock
- 1 Meter drop per IEC 61010-1:2001
- Vibration
- Per MIL-PRF-28800 for a Class 2 instrument
Environmental Specifications
- Operating Temperature
- -20°C to +55°C
- Storage Temperature
- -40°C to +60°C
- Humidity (Without Condensation)
- 0% - 90% (0°C - 35°C)0% - 70% (35°C - 55°C)
- Operating Altitude
- 2000 m
Safety Specifications
- Overvoltage category
- EN 61010-1 to 1000 V CAT III, 600V CAT IV
- Agency Approvals
- UL, CSA, TÜV, VDE listed
Altre categorie
AttuatoriBlocchiCavi, tubi e tubi flessibiliCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro