Honeywell HVFDSB3A0500G130/U

VFD with Bypass and Disconnect, SmartVFD BYPASS, 208VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass

1 / 3
Honeywell HVFDSB3A0500G130/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass — Inverter e convertitori di frequenza
Immagine di catalogo del produttore
Honeywell HVFDSB3A0500G130/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass — Inverter e convertitori di frequenza
Immagine di catalogo del produttore
Honeywell HVFDSB3A0500G130/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass — Inverter e convertitori di frequenza
Immagine di catalogo del produttore
Honeywell HVFDSB3A0500G130/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass — Inverter e convertitori di frequenza
Honeywell HVFDSB3A0500G130/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass — Inverter e convertitori di frequenza
Honeywell HVFDSB3A0500G130/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass — Inverter e convertitori di frequenza

Descrizione del prodotto

The VFD with Bypass and Disconnect, SmartVFD BYPASS, operates at 208VAC and is designed for a 50 HP capacity. This device is particularly suitable for variable torque applications, effectively managing the speed of fans and pumps in HVAC systems to achieve energy efficiency.

This unit includes a three contactor bypass system, enhancing operational flexibility. It supports a continuous output current of up to 140 A and features an input disconnect for safety during maintenance. The enclosure is rated NEMA 1, suitable for indoor applications.

The drive is equipped with EMC filtering and complies with various regulatory standards including CE, EN 61800-5-1, and cUL. It operates reliably within a temperature range from -40 °F to 158 °F and can handle humidity levels up to 95%. The SmartVFD also features built-in PID control capabilities, allowing for integration with building automation systems or standalone operation.

Notable specifications include a maximum deceleration and acceleration time of up to 3000 seconds, ensuring smooth control over varying operational demands. The device also includes analog input and output options for enhanced control and monitoring, making it a versatile choice for HVAC applications.

  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
Invia una richiesta di prezzo
Invia la richiesta
Metodi di pagamento:
Richiedete un preventivo e vi invieremo informazioni su disponibilità e prezzi.

Specifiche tecniche

Marchio
Honeywell
Type of RFI Filter
EMC Filter
Relay Rated Load
Max load: 250Vac/2A- 250Vdc/0.4A
Regulatory Approvals
CE ; EN 61800-5-1 ; cUL
Reference Output Voltage
10 Vdc- max load 10 mA
Pilot Lights
Yes
Peak Current
IS- 2s/20s

Accedi alla nostra piattaforma per trovare altre offerte

Registratevi ora per esplorare 36 mln di offerte da fornitori verificati in tutto il mondo.

  • Confrontare le offerte a livello globale
  • Contatto diretto con i fornitori
  • RFQ, preventivi e ordini
  • Ricerca della distinta base
RegistratiDisponibile una prova gratuita di 14 giorni

Documenti

Scheda tecnica

Scheda tecnica per Honeywell HVFDSB3A0500G130/U, incluse specifiche e caratteristiche.

Scarica scheda dati
TracePartsTraceParts

Modelli CAD

Modello CAD 3D e disegni tecnici, pronti per il tuo software di progettazione.

Scarica modello CAD

Approfondimenti sul mercato

AutomaINSIGHTS cruscotto di analisi

Ottenere dati analitici e di mercato in tempo reale per ottimizzare le decisioni di acquisto di questo componente e di prodotti simili

  • Dati sulla disponibilità di magazzino in tempo reale da oltre 700 distributori MRO in Europa e negli Stati Uniti.
  • Analisi dei prezzi per condizione (nuovo, usato, ricondizionato) con prezzi mediani di mercato
  • Monitoraggio della disponibilità dei componenti critici per prevenire i tempi di inattività della produzione
  • Ottimizzazione dell'inventario in base alle tendenze di approvvigionamento del mercato
Inizia