Hai bisogno di ulteriori informazioni?

Chiamaci al:+48 17 778 34 19

Honeywell HVFDSB3B0250G231/U

VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 25 HP, NEMA 12 Enclosure

1 / 3
Honeywell HVFDSB3B0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 25 HP, NEMA 12 Enclosure — Alimentazione
Immagine di catalogo del produttore
Honeywell HVFDSB3B0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 25 HP, NEMA 12 Enclosure — Alimentazione
Immagine di catalogo del produttore
Honeywell HVFDSB3B0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 25 HP, NEMA 12 Enclosure — Alimentazione
Immagine di catalogo del produttore
Honeywell HVFDSB3B0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 25 HP, NEMA 12 Enclosure — Alimentazione
Honeywell HVFDSB3B0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 25 HP, NEMA 12 Enclosure — Alimentazione
Honeywell HVFDSB3B0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 25 HP, NEMA 12 Enclosure — Alimentazione

Descrizione del prodotto

The variable frequency drive (VFD) features a bypass and disconnect functionality, specifically designed for HVAC applications. With a rated power of 25 HP and operating at 230 Vac, this model includes a three contactor bypass system with an automatic bypass feature. The drive falls under the SmartVFD HVAC family, ensuring compatibility with various systems.

This VFD incorporates an EMC filter for RFI suppression and a control transformer, enhancing its operational reliability. Its dimensions measure 24 inches in width, 65.5 inches in height, and 13.5 inches in depth, weighing 175 pounds. The design adheres to regulatory approvals including CE, EN 61800-5-1, and cUL.

Operational flexibility is provided through adjustable acceleration and deceleration times, ranging from 0.1 seconds to a maximum of 3000 seconds. The drive supports variable torque applications and offers multiple analog input and output options for seamless integration into building automation systems.

The minimum operating temperature is 14 °F with a maximum of 104 °F, and it operates efficiently within a humidity range of 0% to 95%. Overall, the VFD is engineered for effective energy savings by modulating the speed of motors in HVAC systems while facilitating user-friendly setup through its graphical interface.

  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
Invia una richiesta di prezzo
Invia la richiesta
Metodi di pagamento:
Richiedete un preventivo e vi invieremo informazioni su disponibilità e prezzi.

Specifiche tecniche

Marchio
Honeywell
Type of RFI Filter
EMC Filter
Relay Rated Load
Max load: 250Vac/2A- 250Vdc/0.4A
Regulatory Approvals
CE ; EN 61800-5-1 ; cUL
Reference Output Voltage
10 Vdc- max load 10 mA
Pilot Lights
Yes
Peak Current
IS- 2s/20s

Accedi alla nostra piattaforma per trovare altre offerte

Registratevi ora per esplorare 36 mln di offerte da fornitori verificati in tutto il mondo.

  • Confrontare le offerte a livello globale
  • Contatto diretto con i fornitori
  • RFQ, preventivi e ordini
  • Ricerca della distinta base
RegistratiDisponibile una prova gratuita di 14 giorni

Documenti

Scheda tecnica

Scheda tecnica per Honeywell HVFDSB3B0250G231/U, incluse specifiche e caratteristiche.

Scarica scheda dati
TracePartsTraceParts

Modelli CAD

Modello CAD 3D e disegni tecnici, pronti per il tuo software di progettazione.

Scarica modello CAD

Prodotti correlati

HVFDSB3C0750G220/U Honeywell
HVFDSB3C0750G220/U
Honeywell
Variable frequency drive (VFD) designed for HVAC applications, featuring a bypass and disconnect, operating at 460VAC and 75 HP.
HVFDSB3B0750G310/U Honeywell
HVFDSB3B0750G310/U
Honeywell
This variable frequency drive (VFD) is designed for HVAC systems, operating at 230 Vac with a power rating of 75 HP and features a graphical interface and NEMA 3R enclosure.
E50-208100-J06-N-KIT Honeywell
E50-208100-J06-N-KIT
Honeywell
5000 Class Submeter designed for 3-phase applications, rated at 100 A with an input voltage of 120/208-240 V AC.
E50-208100-J05SCS-NS Honeywell
E50-208100-J05SCS-NS
Honeywell
This three-phase submeter operates at 100 A and supports input voltages of 120/208-240 V AC without integrated sensors.
E34-600400-J05-X-KIT-NS Honeywell
E34-600400-J05-X-KIT-NS
Honeywell
Three-phase submeter designed for 400 A current and 347/600 V AC voltage without current sensors.
E32-2083200MEZ7KIT Honeywell
E32-2083200MEZ7KIT
Honeywell
The CLASS 3200 SUBMETER measures electrical usage in three-phase systems with a current rating of 3200 A at input voltages of 120/208-240 V AC.
E32-400200-JEZ7-SPSCS Honeywell
E32-400200-JEZ7-SPSCS
Honeywell
The CLASS 3200 SUBMETER supports 1 or 2-phase configurations and offers a current rating of 200 A with a voltage range of 230/400 V AC.
E32-4803200MEZ7KIT Honeywell
E32-4803200MEZ7KIT
Honeywell
The CLASS 3200 SUBMETER is a 3-phase meter rated at 3200 A and designed for 277/480 V AC applications.
E34-480100-J02-SPKIT Honeywell
E34-480100-J02-SPKIT
Honeywell
The CLASS 3400 SUBMETER is designed for 1 or 2 phase applications with a current rating of 100 A and operates at 277/480 V AC.
E20-600800-M-G-KIT-NS Honeywell
E20-600800-M-G-KIT-NS
Honeywell
This device measures kW and kWh for three-phase power without included sensors, suitable for commercial and industrial applications.
E32-4001600JEZ7KIT Honeywell
E32-4001600JEZ7KIT
Honeywell
The CLASS 3200 SUBMETER is designed for three-phase applications, rated at 1600 A with a voltage configuration of 230/400 V AC.
E20-2081600RKIT-NS Honeywell
E20-2081600RKIT-NS
Honeywell
CLASS 2000 SUBMETER - NO SENSORS, 3 Phase, 1600 A, 120/208-240 V AC provides detailed kW and kWh data for three-phase power systems.

Approfondimenti sul mercato

AutomaINSIGHTS cruscotto di analisi

Ottenere dati analitici e di mercato in tempo reale per ottimizzare le decisioni di acquisto di questo componente e di prodotti simili

  • Dati sulla disponibilità di magazzino in tempo reale da oltre 700 distributori MRO in Europa e negli Stati Uniti.
  • Analisi dei prezzi per condizione (nuovo, usato, ricondizionato) con prezzi mediani di mercato
  • Monitoraggio della disponibilità dei componenti critici per prevenire i tempi di inattività della produzione
  • Ottimizzazione dell'inventario in base alle tendenze di approvvigionamento del mercato
Inizia