Mersen

MPDB68160

1 / 1
thumbnail

Descrizione

The Next Generation Power Distribution Block (PDB). Mersen power distribution blocks provide a safe and easy method of splicing cables, splitting primary power into secondary circuits and fulfilling requirements for fixed junction tap-off points. All blocks are UL and CSA approved while meeting spacing requirements for feeder and branch circuits in conjunction with UL508A and the National Electrical Code®. PDB options include single or dual conductor primary inputs and up to 30 secondary outputs. Specialty blocks are available allowing for up to 7 primary inputs. The MPDB series is offered in three size categories miniature (MPDB62 and MPDB63 series), intermediate (MPDB66 and MPDB67 series), and large (MPDB68 and MPDB69 series), in both aluminum and copper.
Country of Origin
MX
Part Number
MPDB68160
UPC
782001455309
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
Invia una richiesta di prezzo
1
Metodi di pagamento:
Richiedete un preventivo e vi invieremo informazioni su disponibilità e prezzi.

Specifications

Adder Poles
All sizes have optional adder poles for increased flexibility and ease-of-use. Adder poles can be stacked to form multi-pole units in the field without the use of tools. Adder poles allow for customization of primary and secondary wire combinations. End barriers are also available for sale, catalog numbers can be found in the catalog number selection tables for each size block.
Wire Connectors
Standard aluminum and copper wire connectors are available. Aluminum connectors accept both AL or CU wire while copper connectors accept CU wire only. Connectors are all 1-piece tin-plated. Many part numbers are rated to accept DLO-type fine-strand wire, allowing users to connect flexible conductors.
Insulators
Insulators are virtually unbreakable, made of glass-filled polycarbonate. “See-through,” hinged safety covers are optional and provide a greater degree of safety and shock resistance where required. Hinged covers can be installed without tools.
Spacings
1 inch through air and 2 inches over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL508A.
Safety Covers
Polycarbonate safety covers provide dead-front protection. One cover is needed for each pole. Each cover has a test probe hole in the center for circuit checking. Covers are optional accessories and catalog numbers can be found in the catalog selection tables for each size block.
Max Operating Temp
80 °C
Max Storage Temp
80 °C
Min Storage Temp
-25 °C
Rated Voltage Ac Ul
1000 V
Rated Voltage Dc Ul
1000 V
Short Circuit Rating Standalone
10 kA
Short Circuit Rating Class Cc
30 kA
Short Circuit Rating Class G
60 kA
Short Circuit Rating Class J
400 kA
Short Circuit Rating Class L
400 kA
Short Circuit Rating Class Rk1
200 kA
Short Circuit Rating Class Rk5
100 kA
Short Circuit Rating Class T
400 kA
Ampere Rating Cu
350 A
Hole Diameter Primary
0.44 in
Hole Diameter Secondary
0.27 in
Country Of Origin
MX
Product Line
MPDB Series UL 1953 Open-Style Power Distribution Blocks
Wire Insulation Rating
60/75C
Wire Type
Solid/Stranded CU
Body Insulating Material
GFPC
Installation Mounting
Direct Screw Mount
Number Of Poles
Adder
Flammability Rating
94 V-0
Connector Material
Tin-plated Copper
Connector Type Primary
Box
Connector Type Secondary
Box
Hex Screw Size And Type Primary
3/8-24 x .56
Hex Screw Size And Type Secondary
5/16-24 x .38
Number Of Openings Per Pole Primary
2
Number Of Openings Per Pole Secondary
12
Torque Rating Primary
2/0-#3 50; #4-#6 45; #8 40; #10-#14 35
Torque Rating Secondary
#4-#6 45; #8 40; #10-#14 35
Wire Range Primary
2/0-#14
Wire Range Secondary
#4-#14

Documenti

Data Sheet

Scaricare