Phoenix Contact
1186850
Controller - SOL-SA-PCU-41XX-250KW - 1186850
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
Invia una richiesta di prezzo
Additional Information
- Part Number
- 1186850
- UPC
- 4063151229627
- ETIM
- Group Code : EG000024
- Group Description : PLC's
- Class Description : PLC CPU-module
- Class Code : EC000236
- Version : 7
Mechanical design
- Weight
- 215 g
Dimensions
- Width
- 45 mm
- Height
- 126.93 mm
- Depth
- 75 mm
PROFINET
- Device function
- PROFINET controller, PROFINET device
- Specification
- Version 2.3
- Update rate
- min. 1 ms (4 devices)
- Update rate
- min. 16 ms (64 devices)
Control system
- Engineering tool
- PLCnext Engineer
- Engineering tool
- Eclipse
- Programming languages supported
- Programming in acc. with IEC 61131-3
- Programming languages supported
- C++
- Programming languages supported
- C#
- Programming languages supported
- Java
- Programming languages supported
- Manufacturer-specific
- Supports cloud computing
- yes
- Cloud platform
- Proficloud
General data
- Operating system
- Linux
Ambient conditions
- Degree of protection
- IP20
- Ambient temperature (operation)
- -25 °C - 60 °C up to 2000 m above mean sea level (observe derating)
- Ambient temperature (operation)
- -25 °C - 55 °C up to 3000 m above mean sea level (observe derating)
- Ambient temperature (operation)
- ≤ 55 °C (with max. 1 A on UBus)
- Ambient temperature (operation)
- > 55 °C - 60 °C (only in conjunction with an Axioline F power module AXL F PWR 1H (order number 2688297))
- Ambient temperature (storage/transport)
- -40 °C - 85 °C
- Permissible humidity (operation)
- 5 % - 95 % (according to DIN EN 61131-2)
- Permissible humidity (storage/transport)
- 5 % - 95 % (according to DIN EN 61131-2)
- Air pressure (operation)
- 70 kPa - 106 kPa (up to 3000 m above sea level)
- Air pressure (storage/transport)
- 58 kPa - 106 kPa (up to 4500 m above mean sea level)
- Shock
- 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
- Vibration (operation)
- 5g
IEC 61131 runtime system
- Engineering tool
- PLCnext Engineer
- Engineering tool
- Eclipse
- Program memory
- 8 Mbyte
- Mass storage
- 16 Mbyte
- Retentive mass storage
- 48 kByte (NVRAM)
- Realtime clock
- Yes
Standards and Regulations
- Electromagnetic compatibility
- Conformance with EMC Directive 2014/30/EU
- Interference emission
- Noise emission test as per EN 61000-6-4 Class A
- Immunity to surge
- Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
- Immunity to burst
- Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Immunity to EF
- Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Immunity to ESD
- Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Immunity to conducted interference
- Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Vibration (storage/transport)
- 5g
- Shock
- 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
- Vibration (operation)
- 5g
- Shock (operation)
- 10g (Bump endurance test according to DIN EN 60068-2-27)
Fieldbus function
- Designation
- System limits of the controller
- Amount of process data
- max. 4096 Bit (Input)
- Amount of process data
- max. 4096 Bit (Output)
- Number of supported devices
- max. 63 (per station)
- Number of local bus devices that can be connected
- max. 63 (observe current consumption)
- Program memory
- 8 Mbyte
Data interfaces
- Interface
- Axioline F local bus
- Number
- 1
- Connection method
- Bus base module
- Number
- 2
- Connection method
- RJ45 jack