High Current Connectors - UHV 95-M12/M12 - 2130224
2130224
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
Invia una richiesta di prezzo
1
Metodi di pagamento:
Richiedete un preventivo e vi invieremo informazioni su disponibilità e prezzi.
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
Invia una richiesta di prezzo

Additional Information

Part Number
2130224
UPC
4017918053000
Country of Origin
IN
ETIM
Group Code : EG000012
Group Description : Terminal blocks
Class Description : Feed-through terminal block
Class Code : EC000897
Version : 7

Dimensions

Width
40 mm
Length
110 mm
Height NS 35/15
56 mm

Connection data

Connection
1 level
Connection method
Bolt connection
Stripping length
29 mm
Tightening torque, min
15 Nm
Tightening torque max
20 Nm
Connection in acc. with standard
IEC 60947-7-1
Conductor cross section solid min.
35 mm²
Conductor cross section solid max.
95 mm²
Conductor cross section flexible min.
35 mm²
Conductor cross section flexible max.
95 mm²
Min. AWG conductor cross section, flexible
2
Max. AWG conductor cross section, flexible
3/0
Conductor cross section flexible, with ferrule without plastic sleeve min.
35 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
95 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.
35 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
95 mm²
2 conductors with same cross section, solid min.
25 mm²
2 conductors with same cross section, solid max.
35 mm²
2 conductors with same cross section, stranded min.
25 mm²
2 conductors with same cross section, stranded max.
35 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
16 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
35 mm²
Cable lug connection according to standard
DIN 46234:1980-03
Min. cross section for cable lug connection
10 mm²
Max. cross section for cable lug connection
95 mm²
Hole diameter, min.
13 mm
Bolt diameter
12 mm
Screw thread
M12
Tightening torque, min
25 Nm
Tightening torque max
30 Nm
Cable lug connection according to standard
DIN 46235:1983-07
Min. cross section for cable lug connection
25 mm²
Power rail
30 mm x 5 mm

Standards and Regulations

Connection in acc. with standard
CSA
Connection in acc. with standard
IEC 60947-7-1
Flammability rating according to UL 94
HB

Environmental Product Compliance

China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values