Phoenix Contact
2304393
1 / 1
Descrizione
Round cable set; controller: Emerson Delta V; connection 1: IDC/FLK socket strip (1x 16-position); connection 2: IDC/FLK socket strip (1x 14-position); cable length: 0.5 m- Country of Origin
- DE
- Part Number
- 2304393
- Tariff Code
- 85444290
- EAN
- 4017918933043
- UPC
- 4017918933043
- ETIM
- Group Code : EG000024
- Group Description : PLC's
- Class Description : PLC connection cable
- Class Code : EC000237
- Version : 7
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Supported controller
- Controller
- Emerson DeltaV
- Suitable I/O card
- VE4001S2T1B3
- Suitable I/O card
- VE4001S2T2B3
Connection data 2
- Connection name
- Controller level
- Connection in acc. with standard
- IEC 60603-13
- Connection method
- IDC/FLK socket strip
- Number of connections
- 1
- Number of positions
- 16
- Insertion/withdrawal cycles
- > 50
- Pitch
- 2.54 mm
Connection data
- Connection name
- Field level
- Connection in acc. with standard
- IEC 60603-13
- Connection method
- IDC/FLK socket strip
- Number of connections
- 1
- Number of positions
- 14
- Insertion/withdrawal cycles
- > 50
- Pitch
- 2.54 mm
Ambient conditions
- Ambient temperature (operation)
- -40 °C - 70 °C (fixed installation)
- Ambient temperature (operation)
- -10 °C - 70 °C (flexible installation)
- Ambient temperature (storage/transport)
- -40 °C - 80 °C
- Maximum altitude
- ≤ 2000 m
- Degree of protection
- IP00
- Degree of protection
- ≥ IP54 (Installation location)
Environmental Product Compliance
- China RoHS
- Environmentally Friendly Use Period = 50 years
- China RoHS
- For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'
Standards and Regulations
- Flame resistance
- UL VW-1
- Flame resistance
- CSA FT-1
- Flame resistance
- IEC 60332-1-2
- Flame resistance
- VDE 0842, Part 332-1-2
- Flame resistance
- IEC 60332-3-22
- Resistance to oil
- against occasional splashes
- Gasoline resistance
- against occasional splashes
- Designation
- Air clearances and creepage distances
- Standards/regulations
- DIN EN 50178
- Rated insulation voltage
- 63 V
- Rated surge voltage
- 0.6 kV
- Insulation
- Functional insulation
- Pollution degree
- 2
- Overvoltage category
- II
Color code
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (1) = IDC/FLK14 (1) = black
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (2) = IDC/FLK14 (9) = brown
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (3) = IDC/FLK14 (2) = red
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (4) = IDC/FLK14 (9) = orange
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (5) = IDC/FLK14 (3) = yellow
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (6) = IDC/FLK14 (9) = green
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (7) = IDC/FLK14 (4) = blue
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (8) = IDC/FLK14 (11) = violet
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (9) = IDC/FLK14 (5) = gray
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (10) = IDC/FLK14 (11) = white
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (11) = IDC/FLK14 (6) = white-black
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (12) = IDC/FLK14 (11) = white-brown
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (13) = IDC/FLK14 (7) = white-red
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (14) = IDC/FLK14 (13) = white-orange
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (15) = IDC/FLK14 (8) = white-yellow
- Connector 1 = connector 2 (optional) = wire color
- IDC/FLK16 (16) = IDC/FLK14 (13) = white-green