Phoenix Contact
2800809
1 / 1
Descrizione
Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for two 2-wire floating signal circuits. Indirect grounding via gas-filled surge arrester.- Country of Origin
- DE
- Part Number
- 2800809
- Tariff Code
- 85363010
- EAN
- 4046356665261
- UPC
- 4046356665261
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Additional descriptions
- Note
- Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
Dimensions
- Height
- 91.1 mm
- Width
- 17.7 mm
- Depth
- 77.5 mm (incl. DIN rail 7.5 mm)
- Horizontal pitch
- 1 Div.
Connection data
- Connection method
- Screw connection
- Screw thread
- M3
- Tightening torque
- 0.5 Nm
- Stripping length
- 8 mm
- Conductor cross section flexible
- 0.2 mm² - 2.5 mm²
- Conductor cross section solid
- 0.2 mm² - 4 mm²
- Conductor cross section AWG
- 24 - 12
Connection, equipotential bonding
- Connection method
- DIN rail NS35
Ambient conditions
- Ambient temperature (operation)
- -40 °C - 70 °C
- Ambient temperature (storage/transport)
- -40 °C - 85 °C
- Altitude
- ≤ 4000 m (amsl (above mean sea level))
- Degree of protection
- IP20
Environmental Product Compliance
- REACh SVHC
- Lead 7439-92-1
Protective circuit
- IEC test classification
- C1
- IEC test classification
- C2
- IEC test classification
- C3
- IEC test classification
- D1
- Nominal voltage U<sub>N</sub>
- 5 V DC
- Maximum continuous voltage U<sub>C</sub>
- 6 V DC
- Maximum continuous voltage U<sub>C</sub>
- 4 V AC
- Rated current
- 700 mA (50 °C)
- Operating effective current I<sub>C</sub> at U<sub>C</sub>
- ≤ 2 mA (in the signal circuit)
- Residual current I<sub>PE</sub>
- ≤ 1 µA
- Nominal discharge current I<sub>n</sub> (8/20) µs (line-line)
- 10 kA
- Nominal discharge current I<sub>n</sub> (8/20) µs (line-earth)
- 10 kA
- Pulse discharge current I<sub>imp</sub> (10/350) µs (line-earth)
- 2.5 kA
- Pulse discharge current I<sub>imp</sub> (10/350) µs (line-signalground)
- 2.5 kA
- Total discharge current I<sub>total</sub> (8/20) µs
- 20 kA
- Voltage protection level U<sub>p</sub> (line-line)
- ≤ 85 V (C1 - 1 kV/500 A)
- Voltage protection level U<sub>p</sub> (line-line)
- ≤ 110 V (C2 - 10 kV / 5 kA)
- Voltage protection level U<sub>p</sub> (line-line)
- ≤ 140 V (C2 - 10 kA)
- Voltage protection level U<sub>p</sub> (line-line)
- ≤ 25 V (C3 - 25 A)
- Voltage protection level U<sub>p</sub> (line-line)
- ≤ 25 V (C3 - 50 A)
- Voltage protection level U<sub>p</sub> (line-earth)
- ≤ 900 V (C1 - 1 kV/500 A)
- Voltage protection level U<sub>p</sub> (line-earth)
- ≤ 1300 V (C2 - 10 kV / 5 kA)
- Voltage protection level U<sub>p</sub> (line-earth)
- ≤ 1200 V (C2 - 10 kA)
- Voltage protection level U<sub>p</sub> (line-earth)
- ≤ 1000 V (C3 - 25 A)
- Voltage protection level U<sub>p</sub> (line-earth)
- ≤ 1300 V (C3 - 100 A)
- Voltage protection level U<sub>p</sub> (line-signalground)
- ≤ 600 V (C1 - 1 kV/500 A)
- Voltage protection level U<sub>p</sub> (line-signalground)
- ≤ 750 V (C2 - 10 kV / 5 kA)
- Voltage protection level U<sub>p</sub> (line-signalground)
- ≤ 800 V (C2 - 10 kA)
- Voltage protection level U<sub>p</sub> (line-signalground)
- ≤ 700 V (C3 - 25 A)
- Voltage protection level U<sub>p</sub> (line-signalground)
- ≤ 800 V (C3 - 100 A)
- Voltage protection level U<sub>p</sub> static (line-line)
- ≤ 26 V (C1 - 1 kV/500 A)
- Voltage protection level U<sub>p</sub> static (line-line)
- ≤ 70 V (C2 - 10 kV / 5 kA)
- Voltage protection level U<sub>p</sub> static (line-line)
- ≤ 30 V (C2 - 10 kA)
- Response time t<sub>A</sub> (line-line)
- ≤ 1 ns
- Response time tA (line-signalground)
- ≤ 100 ns
- Response time t<sub>A</sub> (line-earth)
- ≤ 100 ns
- Input attenuation aE, sym.
- typ. 0.3 dB (≤ 40 kHz/150 Ω)
- Cut-off frequency fg (3 dB), sym. in 150 Ohm system
- typ. 300 kHz
- Capacity (line-line)
- typ. 7.5 nF
- Resistance in series
- 1.2 Ω ±5 %
- Surge protection fault message
- Optical, multi-stage
- Max. required back-up fuse
- 800 mA (FF)
- Impulse durability (line-line)
- C1 - 1 kV/500 A
- Impulse durability (line-line)
- C2 - 10 kV/5 kA
- Impulse durability (line-line)
- C2 - 10 kA
- Impulse durability (line-line)
- C3 - 50 A
- Impulse durability (line-earth)
- C1 - 1 kV/500 A
- Impulse durability (line-earth)
- C2 - 10 kV/5 kA
- Impulse durability (line-earth)
- C2 - 10 kA
- Impulse durability (line-earth)
- C3 - 100 A
- Impulse durability (line-earth)
- D1 - 2.5 kA
- Impulse durability (line-signalground)
- C1 - 1 kV/500 A
- Impulse durability (line-signalground)
- C2 - 10 kV/5 kA
- Impulse durability (line-signalground)
- C2 - 10 kA
- Impulse durability (line-signalground)
- C3 - 100 A
- Impulse durability (line-signalground)
- D1 - 2,5 kA
- Pulse reset time (line-line)
- ≤ 10 ms
- Pulse reset time (line-earth)
- ≤ 10 ms
- Pulse reset time (line-signalground)
- ≤ 10 ms
Standards and Regulations
- Standards/specifications
- IEC 61643-21 2000 + A1:2008, modified
- Standards/specifications
- EN 61643-21 2001 + A1:2009
- Standards/specifications
- EN 61000-6-2 2007 + A1:2011
- Standards/specifications
- EN 61000-6-3 2005
Altre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro