Additional Information
- Part Number
- 101213959
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : End switch
- Class Code : EC000030
- Version : 7
Electrical data - Safety digital inputs
- Designation, Safety inputs
- X1 and X2
- Current consumption of the safety inputs
- 5 mA
- Test pulse duration, maximum
- 1 ms
- Test pulse interval, minimum
- 100 ms
- Classification ZVEI CB24I, Sink
- C1
- Classification ZVEI CB24I, Source
- C1 | C2 | C3
Electrical data
- Operating voltage
- 24 VDC -15 % / +10 % (stabilised PELV power supply)
- Operating current, minimum
- 0.5 mA
- No-load supply current I
- 35 mA
- Rated operating voltage
- 24 VDC
- Operating current
- 600 mA
- Required rated short-circuit current
- 100 A
- Time to readiness, maximum
- 2,000 ms
- Switching frequency, maximum
- 1 Hz
Note
- Note (General)
- Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.5 ms. Short-circuit recognition by the evaluation is not necessary.
Mechanical data - Dimensions
- Length of sensor
- 22 mm
- Width of sensor
- 106.3 mm
- Height of sensor
- 25 mm
Pin assignment
- PIN 1
- 1A1 Ue: (1)
- PIN 2
- X1 Safety input 1
- PIN 3
- A2 GND Blue
- PIN 4
- Y1 Safety output 1 Black
- PIN 5
- OUT Diagnostic output OUT Grey
- PIN 6
- X2 Safety input 2 violet
- PIN 7
- Y2 Safety output 2 red
- PIN 8
- IN without function Pink
Ambient conditions - Insulation values
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution
- 3
Scope of delivery
- Scope of delivery
- Actuator must be ordered separately.
General data - Features
- Latching
- Yes
- Diagnostic output
- Yes
- Short circuit detection
- Yes
- Cross-circuit detection
- Yes
- Series-wiring
- Yes
- Safety functions
- Yes
- Cascadable
- Yes
- Integral system diagnostics, status
- Yes
- Number of LEDs
- 3
- Number of semi-conductor outputs with signaling function
- 1
- Number of fail-safe digital outputs
- 2
General data
- Standards
- EN ISO 13849-1 | EN IEC 60947-5-3 | EN IEC 61508
- Coding
- Universal coding
- Coding level according to EN ISO 14119
- Low
- Working principle
- RFID
- Frequency band RFID
- 125 kHz
- Transmitter output RFID, maximum
- -6 dB/m
- Housing construction form
- Block
- Installation conditions (mechanical)
- not flush
- Sensor topology
- Sensor for series wiring
- Enclosure material
- Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Active area
- Glass-fibre, reinforced thermoplastic
- Gross weight
- 295 g
- Reaction time, maximum
- 100 ms
- Duration of risk, maximum
- 200 ms
- Reaction time, switching off safety outputs via actuator, maximum
- 100 ms
- Reaction time, switching off safety outputs via safety inputs, maximum
- 0.5 ms
Safety classification
- Standards
- EN ISO 13849-1 | EN IEC 61508
- Performance Level, up to
- e
- Category
- 4
- PFH value
- 2.70 x 10⁻¹⁰ /h
- PFD value
- 2.10 x 10⁻⁵
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission time
- 20 Year(s)
Electrical data - Safety digital outputs
- Designation, Safety outputs
- Y1 and Y2
- Rated operating current (safety outputs)
- 250 mA
- Output current, (fail-safe output), maximum
- 0.25 A
- Design of control elements
- short-circuit proof, p-type
- Voltage drop U
- 1 V
- Leakage current I
- 0.5 mA
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.25 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.25 A
- Test pulse interval, typical
- 1000 ms
- Test pulse duration, maximum
- 0.3 ms
- Classification ZVEI CB24I, Source
- C2
- Classification ZVEI CB24I, Sink
- C1 | C2
Ambient conditions
- Degree of protection
- IP65 | IP67 | IP69
- Ambient temperature
- -25 ... +70 °C
- Storage and transport temperature, minimum
- -25 °C
- Storage and transport temperature, maximum
- +85 °C
- Material temperature resistance of the cable (in motion), minimum
- -10 °C
- Material temperature resistance of the cable (at rest), minimum
- -30 °C
- Relative humidity, maximum
- 93 %
- Note (Relative humidity)
- non-condensing | non-icing
- Resistance to vibrations
- 10 … 55 Hz, amplitude 1 mm
- Restistance to shock
- 30 g / 11 ms
- Protection class
- III
- Permissible installation altitude above sea level, maximum
- 2,000 m
Mechanical data - Connection technique
- Termination
- Cable (Y-UL 2517), 8-pole
- Note (length of the sensor chain)
- Cable length and cross-section change the voltage drop dependiing on the output current
- Note (series-wiring)
- Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
- Length of cable
- 2 m
- Cable section, maximum
- 8 x 0.35 mm²
- Wire cross-section
- 22 AWG
- Cable type
- LiYY
Electrical data - Diagnostic outputs
- Designation, Diagnostic outputs
- OUT
- Design of control elements
- short-circuit proof, p-type
- Voltage drop U
- 2 V
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.05 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.05 A
Mechanical data - Switching distances according EN IEC 60947-5-3
- Switch distance, typical
- 12 mm
- Assured switching distance "ON" S
- 10 mm
- Assured switching distance "OFF" S
- 16 mm
Mechanical data
- Actuating panels
- lateral
- Active area
- lateral
- Mechanical life, minimum
- 1,000,000 Operations
- Note (Mechanical life)
- Actuating speed < 0.25 m/s | Operations for door weights ≤ 5 kg
- Hysteresis (Switching distance), maximum
- 2 mm
- Repeat accuracy R
- 0.5 mm
- Note (Repeat accuracy R)
- Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle).Minimum clearance between two sensor systems 100 mm.
- Latching force, approx.
- 18 N
- Mounting
- A screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used.
- Type of the fixing screws
- 2x M4 (cylinder head screws with washers DIN 125A / form A)
- Tightening torque of the fixing screws, minimum
- 2.2 Nm
- Tightening torque of the fixing screws, maximum
- 2.5 Nm
Accessory
- Recommendation (actuator)
- RST 36-1 | RST 36-1-R
- Recommended safety switchgear
- PROTECT PSC1 | SRB-E-301ST | SRB-E-201LC
Approvals - Standards
- Certificates
- cULus | ECOLAB | FCC | IC
Electrical data - Electromagnetic compatibility (EMC)
- Interfering radiation
- IEC 61000-6-4
- EMC rating
- IEC 60947-3
Status indication
- Note (LED switching conditions display)
- LED yellow: Operating condition | LED green: Supply voltage | LED red: Fault
Altre categorie
NanometriManometriFlussimetriSensoriSensori di accelerazioneSensori in fibra otticaRilevatoriSensori ad ultrasuoniSensori di temperatura e umiditàSensori di vibrazioneSensori di livelloSensori di pressioneSensori di prossimitàSensori induttiviSensori di movimentoGruppo di Sensori MagneticiSensori otticiSensori capacitiviSensori FotoelettriciSensori di posizioneEncoderAltri Sensori e Accessori