Schneider Electric
9AS3A120
1 / 5
Descrizione
Attivo maturo
- Country of Origin
- CN
- Part Number
- 9AS3A120
- Tariff Code
- 8536490050
- EAN
- 39122324
- UNSPSC
- 39122324
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Environment
- Product Certifications
- UL
- Height
- 50 mm
- Ambient Air Temperature For Operation
- -40-40 °C
- Ambient Air Temperature For Storage
- -40-85 °C
- Standards
- UL 60947-4-1
- Pollution Degree
- 3
- Shock Resistance
- 10 gn operating || 100 gn not operating
- Vibration Resistance
- +/- 0.75 mm 10-55 Hz operating || +/- 0.75 mm 10-55 Hz not operating
- Width
- 27.3 mm
- Depth
- 27.8 mm
Complementary
- Network Frequency
- 50-60 Hz
- Average Consumption
- 2.6 VA
- [Ie] Rated Operational Current
- 30 A at 240 V AC-1 || 30 A at 28 V DC (on resistive load) || 24 A at 240 V AC (on resistive load) || 98 A at 120 V AC-8a (locked rotor) || 22 A at 120 V AC-8a (full load) || 10 A at 277 V AC-5a (ballast)
- Connections - Terminals
- Faston terminals contact terminal AWG 12...AWG 10, connection size: 6.35 x 0.8 mm || Faston terminals coil terminal AWG 22...AWG 14, connection size: 4.8 x 0.5 mm
- Control Circuit Voltage Limits
- 0.85...1.1 Uc
- Protection Category
- RT III
- Mounting Support
- panel flange
- Electrical Durability
- 100000 cycles, 30 A at 240 V, AC-1 || 50000 cycles for resistive load, 30 A at 28 V, DC || 100000 cycles for resistive load, 24 A at 240 V, AC || 30000 cycles for full load, 22 A at 120 V, AC-8a || 1000 cycles for motor load || 6000 cycles for ballast load, 10 A at 277 V, AC-5a
- Mechanical Durability
- 10000000 cycles
- Reset Time
- 10 ms
- Rated Power In Hp
- 1 hp at 125 V AC || 2 hp at 250 V AC
- Operating Position
- any position
- Dielectric Strength
- 2500 V AC between coil and contact || 1500 V between contacts with micro disconnection
- [Ui] Rated Insulation Voltage
- 320 V
- Rated Power In Va
- 470 VA at 240 V on pilot duty
- Input Current
- 30 A
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV 1.2/50 µs
- Drop-Out Voltage Threshold
- >= 0.2 Uc
- Minimum Switching Capacity
- 5 W at 1 A, 5 V DC || 12 VA at 1 A, 12 V AC
- Operating Time
- 20 ms
- Net Weight
- 0.032 kg
- Average Resistance
- 2500 Ohm at 23 °C +/- 10 %
Offer Sustainability
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI2006003EN
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP2006003EN
- Phenolic Free Solution
- Yes
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Lead Free
- Yes
- Toxic Heavy Metal Free
- Yes
- Eu Rohs Directive
- Compliant
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Silicon Free
- Yes
Specifications
- [Uc] Control Circuit Voltage
- 120 V AC 50-60 Hz
- Contacts Type And Composition
- NO
- Range Of Product
- Harmony
- Contacts Material
- silver alloy contacts
- Switch Function
- SPST
- Product Or Component Type
- power relay
- Maximum Switching Voltage
- 277 V AC || 28 V DC
Documenti
Data Sheet
ScaricareAltre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro