Specifications
- Product Destination
- asynchronous motors
- Range Of Product
- Altivar 312 Solar
- Product Or Component Type
- variable speed drive
- Product Specific Application
- pumping station with photovoltaic arrays
- Assembly Style
- with heat sink
- Device Short Name
- ATV312
Contractual warranty
- Warranty
- 18 months
Complementary
- Prospective Line Isc
- 1 kA
- Network Frequency
- 47.5...63 Hz
- Discrete Input Logic
- logic input not wired LI1...LI4), < 13 V || negative logic (source) LI1...LI6), > 19 V || positive logic (source) LI1...LI6), < 5 V, > 11 V
- Height
- 184 mm
- Acceleration And Deceleration Ramps
- linear adjustable separately from 0.1 to 999.9 s || S, U or customized
- Line Current
- 6.7 A 500 V || 8.9 A 380 V, Isc = 1 kA
- Time Constant
- 5 ms for reference change
- Electrical Connection
- Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 terminal 2.5-2.5 mm² AWG 14 || L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 2.5-2.5 mm² AWG 14
- Standards
- IEC 61800-3 || IEC 61800-5-1
- Speed Drive Output Frequency
- 0.5-500 Hz
- Discrete Output Type
- configurable relay logic R1A, R1B, R1C) 1 NO + 1 NC - 100000 cycles || configurable relay logic R2A, R2B) NC - 100000 cycles
- Transmission Frame
- RTU
- Asynchronous Motor Control Profile
- factory set: energy saving mode
- Maximum Switching Current
- 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms R1-R2) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms R1-R2) || 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms R1-R2) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms R1-R2)
- Analogue Output Type
- AOC configurable current 0...20 mA 800 Ohm 8 bits || AOV configurable voltage 0...10 V 470 Ohm 8 bits
- Transient Overtorque
- 150-170 % of nominal motor torque
- Electromagnetic Compatibility
- 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
- Insulation Resistance
- >= 500 mOhm 500 V DC for 1 minute
- Marking
- CE
- Dielectric Strength
- 2410 V DC between earth and power terminals || 3400 V AC between control and power terminals
- Response Time
- AOV, AOC 8 ms analog || R1A, R1B, R1C, R2A, R2B 8 ms discrete
- Motor Power Kw
- 2.2 kW
- Phase
- 3 phase
- Power Dissipation In W
- 79 W at nominal load
- Net Weight
- 3.1 kg
- Frequency Resolution
- analog input 0.1...100 Hz || display unit 0.1 Hz
- Connector Type
- 1 RJ45 Modbus/CANopen
- Switching Frequency
- 2...16 kHz adjustable
- Maximum Transient Current
- 8.3 A 60 s
- Number Of Drive
- 127 CANopen || 31 Modbus
- Analogue Input Number
- 3
- Motor Slip Compensation
- suppressable || automatic whatever the load || adjustable
- Discrete Output Number
- 2
- [Us] Rated Supply Voltage
- 380...500 V - 5...5 %
- Discrete Input Type
- LI1...LI6) programmable 24 V, 0-100 mA PLC 3500 Ohm
- Communication Port Protocol
- Modbus || CANopen
- Regulation Loop
- frequency PI regulator
- Supply Voltage Limits
- 323-550 V
- Minimum Switching Current
- R1-R2 10 mA 5 V DC
- Analogue Output Number
- 2
- Physical Interface
- RS485 multidrop serial link
- Transmission Rate
- 10, 20, 50, 125, 250, 500 kbps or 1 Mbps CANopen || 4800, 9600 or 19200 bps Modbus
- Insulation
- electrical between power and control
- Speed Range
- 1-50
- Discrete Input Number
- 6
- Local Signalling
- for drive voltage 1 LED (red) || for CANopen bus status four 7-segment display units
- Linearity Error
- +/- 0.2 % output
- Number Of Addresses
- 1-127 CANopen || 1-247 Modbus
- Apparent Power
- 5.9 kVA
- Output Voltage
- <= power supply voltage
- Nominal Switching Frequency
- 4 kHz
- Emc Filter
- integrated
- Width
- 142 mm
- Analogue Input Type
- AI1 configurable voltage 0...10 V 30 V max 30000 Ohm || AI2 configurable voltage +/- 10 V 30 V max 30000 Ohm || AI3 configurable current 0...20 mA 250 Ohm
- Braking To Standstill
- by DC injection
- Depth
- 152 mm
- Tightening Torque
- Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 0.6-0.6 N.m || L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- 0.8-0.8 N.m
- Continuous Output Current
- 5.5 A 4 kHz
- Protection Type
- input phase breaks drive || line supply overvoltage and undervoltage safety circuits drive || line supply phase loss safety function, for three phases supply drive || motor phase breaks drive || overcurrent between output phases and earth (on power up only) drive || overheating protection drive || short-circuit between motor phases drive || thermal protection motor
- Maximum Horse Power Rating
- 3 hp
- Supply
- internal supply for logic inputs 19...30 V, <100 A overload and short-circuit protection || internal supply for reference potentiometer (2.2 to 10 kOhm) 10...10.8 V, <10 A overload and short-circuit protection
- Braking Torque
- <= 150 % 60 s with braking resistor || 100 % with braking resistor continuously || 150 % without braking resistor
- Supply Frequency
- 50...60 Hz - 5...5 %
- Option Card
- communication card CANopen daisy chain || communication card DeviceNet || communication card Fipio || communication card Modbus TCP || communication card Profibus DP
- Sampling Duration
- AI1, AI2, AI3 8 ms analog || LI1...LI6 4 ms discrete
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP110706EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI100203EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Pollution Degree
- 2
- Ambient Air Temperature For Operation
- -10-50 °C without derating with protective cover on top of the drive) || -10-60 °C with derating factor without protective cover on top of the drive)
- Shock Resistance
- 15 gn 11 ms EN/IEC 60068-2-27
- Vibration Resistance
- 1 gn 13-150 Hz)EN/IEC 60068-2-6 || 1.5 mm 3-13 Hz)EN/IEC 60068-2-6
- Ambient Air Temperature For Storage
- -25-70 °C
- Relative Humidity
- 5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
- Ip Degree Of Protection
- IP20 without cover plate
- Operating Altitude
- <= 3280.84 ft (1000 m) without derating || >= 3280.84 ft (1000 m) with current derating 1 % per 100 m
- Operating Position
- vertical +/- 10 degree
- Protective Treatment
- TC
Documenti
Data Sheet
ScaricareAltre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro