Attivo maturo
This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. This variable speed drive features an integrated EMC filter with 25m cable conforming to category C3. It works at a rated supply voltage from 500V to 690VAC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 5.5kW/7.5HP (500V supply voltage) for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 4kW/5HP (500V supply voltage) for applications requiring significant overload (up to 150%). Its dimensions are 246mm (width) x 242mm (depth) x 420mm (height). It weighs 22kg. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. This product is certified by CE, CSA and TUV. It meets UL 508C, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508 and IEC 13849-1 standards. Accessories (fan kit, graphic display terminal) and options (line chokes, dv/dt filter, sinus filter, EMC filter) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
Country of Origin
IN
Part Number
ATV630U55Y6
Tariff Code
85044095
EAN
3606481325129
UNSPSC
39122001
Metodi di pagamento:
Migliore offerta da:
HKAutoma.Net Fornitore
Disponibilità:
10 pz.
Disponibile
Aggiornato il: 22-11-2024
Garanzia:
12 mesi
Consegna stimata:
Su richiesta
Condizione:
Nuove eccedenze
Nuove eccedenze - Un articolo nuovo, inutilizzato e non danneggiato senza garanzia del produttore. L'articolo può arrivare senza confezione originale o in una confezione sostitutiva. Se fornita, la scatola potrebbe essere stata aperta.
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Complementary

Discrete Input Logic
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Analogue Output Type
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Discrete Output Type
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V DC 5000 mA
Maximum Switching Current
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Exchange Mode
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Phase
3 phase
Net Weight
22 kg
Type Of Polarization
no impedance
Frequency Resolution
display unit 0.1 Hz || analog input 0.012/50 Hz
Relay Output Type
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Maximum Transient Current
7.9 A 60 s normal duty) || 8.1 A 60 s heavy duty)
Analogue Input Number
3
Motor Slip Compensation
adjustable || can be suppressed || automatic whatever the load || not available in permanent magnet motor law
Discrete Output Number
0
Method Of Access
slave Modbus TCP
Discrete Input Number
8
Local Signalling
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Linearity Error
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Number Of Addresses
1-247 Modbus serial
Width
246 mm
Transmission Rate
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Depth
242 mm
Analogue Input Type
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Sampling Duration
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Electrical Connection
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 4...10 mm² AWG 12...AWG 8 || line side screw terminal 4...10 mm² AWG 12...AWG 8
Maximum Output Frequency
500 kHz
Height
420 mm
Acceleration And Deceleration Ramps
linear adjustable separately from 0.01...9999 s || S, U or customized
Transmission Frame
RTU
Relay Output Number
3
Data Format
8 bits, configurable odd, even or no parity
Accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Connector Type
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Input Compatibility
DI1...DI6 discrete input level 1 PLC IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Permissible Temporary Current Boost
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Mounting Mode
wall mount
Analogue Output Number
2
Physical Interface
Ethernet || 2-wire RS 485
Minimum Switching Current
relay output R1, R2, R3 5 mA 24 V DC
Refresh Time
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Enclosure Mounting
wall mounted
Isolation
between power and control terminals
Output Voltage
<= power supply voltage
Quantity Per Set
1
Braking To Standstill
by DC injection
Discrete Input Type
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Protection Type
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || motor phase break drive || overvoltages on the DC bus drive || line supply overvoltage drive || line supply undervoltage drive || line supply phase loss drive || overspeed drive || break on the control circuit drive
Supply
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection

Environment

Product Certifications
TÜV || UL || CSA
Power Dissipation In W
natural convection 82 W 500 V 4 kHz || forced convection 101 W 500 V 4 kHz
Standards
UL 508C || IEC 61800-3 || EN/IEC 61800-3 environment 2 category C3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Insulation Resistance
> 1 MOhm 500 V DC for 1 minute to earth
Shock Resistance
15 gn 11 ms IEC 60068-2-27
Vibration Resistance
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Noise Level
52 dB 86/188/EEC
Regulation Loop
adjustable PID regulator
Operating Altitude
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Overvoltage Category
III
Pollution Degree
2
Electromagnetic Compatibility
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6
Ambient Air Temperature For Operation
-15-50 °C without derating) || 50-60 °C with derating factor)
Volume Of Cooling Air
330 m3/h
Marking
CE
Pollution Degree
2 IEC 61800-5-1
Noise Level
58 dB
Ambient Air Temperature For Storage
-40-70 °C
Relative Humidity
5-95 % without condensation IEC 60068-2-3
Operating Position
vertical +/- 10 degree
Maximum Thdi
<48 % with external line choke IEC 61000-3-12

Offer Sustainability

Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Upgradeability
Upgraded components available
Rohs Exemption Information
Yes
Environmental Disclosure
ENVPEP1704001EN
Sustainable Offer Status
Green Premium product
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile
ENVEOLI1704001EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Specifications

Prospective Line Isc
70 kA
Product Destination
asynchronous motors || synchronous motors
Line Current
7.9 A 500 V normal duty) || 8 A 690 V normal duty) || 6.2 A 500 V heavy duty) || 6.1 A 690 V heavy duty)
Emc Filter
integrated 25 m IEC 61800-3 category C3
Asynchronous Motor Control Profile
constant torque standard || optimized torque mode || variable torque standard
Variant
standard version
Product Or Component Type
variable speed drive
Apparent Power
9.6 kVA 690 V normal duty) || 7.3 kVA 690 V heavy duty)
Switching Frequency
2...8 kHz adjustable || 4...8 kHz with derating factor
Communication Port Protocol
Modbus serial || Modbus TCP || Ethernet
Product Specific Application
process and utilities
Safety Function
STO (safe torque off) SIL 3
Maximum Horse Power Rating
5 hp 500 V normal duty || 7.5 hp 690 V normal duty || 5 hp 690 V heavy duty
Supply Frequency
50...60 Hz - 5...5 %
Option Card
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A communication module, CANopen SUB-D 9 || slot A communication module, CANopen screw terminals || slot A/slot B digital and analog I/O extension module || slot A/slot B output relay extension module || slot A communication module, Ethernet IP/Modbus TCP/MD-Link || communication module, BACnet MS/TP || communication module, Ethernet Powerlink
Range Of Product
Altivar Process ATV600
Speed Drive Output Frequency
0.1-500 Hz
Ip Degree Of Protection
IP00IEC 61800-5-1 || IP00IEC 60529 || IP20 with kit VW3A9705)IEC 61800-5-1 || IP20 with kit VW3A9705)IEC 60529
Motor Power Kw
4 kW 500 V normal duty) || 3 kW 500 V heavy duty) || 5.5 kW 690 V normal duty) || 4 kW 690 V heavy duty)
[Us] Rated Supply Voltage
500...690 V
[Us] Rated Supply Voltage
500...690 V - 15...10 %
Discrete Input Logic
16 preset speeds
Type Of Cooling
forced convection
Continuous Output Current
7.2 A 4 kHz normal duty || 5.4 A 4 kHz heavy duty
Nominal Switching Frequency
4 kHz
Device Short Name
ATV630
Synchronous Motor Control Profile
permanent magnet motor || synchronous reluctance motor