Schneider Electric
BGF26030
1 / 5
Descrizione
PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit has terminal nuts on both termination ends. This PowerPacT B, 30A, 2 pole, circuit breaker has a breaking capacity of 18kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. EverLink lugs are also available with unique integrated control wire terminals.- Country of Origin
- US
- Part Number
- BGF26030
- EAN
- 39121601
- UNSPSC
- 39121601
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Specifications
- Product Or Component Type
- circuit breaker
- Product Name
- PowerPact B
- Range
- PowerPact
- Device Application
- distribution
- Device Short Name
- BG 030
Complementary
- Mounting Mode
- clip-on 35 mm symmetrical DIN rail) || by screws plate)
- Network Frequency
- 50/60 Hz
- [Ics] Rated Service Breaking Capacity
- 65 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 35 kA 440 V AC 50/60 Hz IEC 60947-2
- Trip Unit Technology
- thermal-magneticTM-D,
- Trip Unit Name
- TM-D
- Height
- 137 mm
- Connection Pitch
- 27 mm
- [Ue] Rated Operational Voltage
- 525 V AC 50/60 Hz UL 489
- Tightening Torque
- 5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
- Breaking Capacity Code
- G
- 9 Mm Pitches
- 6
- Local Signalling
- presence of auxiliary contacts flag green)
- Number Of Slots
- 1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
- Protected Poles Description
- 2t
- Electrical Connection
- terminal nut ON and OFF end
- Net Weight
- 0.669 kg
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV IEC 60947-2
- Control Type
- toggle
- Circuit Breaker Application
- HACR rated
- Wire Stripping Length
- 20 mm
- Utilisation Category
- category A
- Line Rated Current
- 30-30 A
- Continuous Current Rating
- 80 %
- Breaking Capacity
- 65 kA 208Y/120 V AC 50/60 Hz UL 489 || 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480/277 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 18 kA 600Y/347 V AC 50/60 Hz UL 489
- [Ui] Rated Insulation Voltage
- 800 V IEC 60947-2
- Mechanical Durability
- 15000 cycles IEC 947-1 Annex K ed 5.2
- Suitability For Isolation
- yes IEC 60947-2
- Electrical Durability
- 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Poles Description
- 2P
- Quantity Per Set
- set of 1
- Awg Gauge
- AWG 14...AWG 8 aluminium/copper || AWG 6...AWG 3/0 aluminium/copper
- Color
- Gray RAL 7016)
- Width
- 54 mm
- Depth
- 80 mm
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1610005EN
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Eu Rohs Directive
- Compliant
- Halogen Content Performance
- Halogen free product
Environment
- Ik Degree Of Protection
- IK07 IEC 62262
- Ambient Air Temperature For Operation
- -25-70 °C
- Standards
- NEMA AB1 || CSA C22.2 No 5 || EN/IEC 60947-5-1 || UL 489 || GB 14048.2 || EN/IEC 60947-2 || NMX J-266
- Product Certifications
- UL || IEC || CCC || EAC || CSA || NOM
- Ip Degree Of Protection
- front cover IP40 IEC 60529
- Pollution Degree
- 3 IEC 60947-1
- Ambient Air Temperature For Storage
- -50-85 °C
- Quality Labels
- CE
- Operating Altitude
- 6561.68 ft (2000 m) without derating || 5000 m with derating