Circuit breaker, PowerPacT B, 70A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
BJF26070
BJF26070
BJF26070
BJF26070
BJF26070
  • Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
  • Sconti sulla rivendita fino al 40%!
Registrati
Invia una richiesta di prezzo
1
Metodi di pagamento:
Offerta con tempi di consegna del produttore
Spedizione in:Su richiesta
Miglior prezzo:
Invia una richiesta di prezzo

Additional Information

Part Number
BJF26070
UNSPSC
39121601
Country of Origin
US

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1610005EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
N/A
Eu Rohs Directive
Compliant with Exemptions
Halogen Content Performance
Halogen free product

Complementary

Mounting Mode
clip-on 35 mm symmetrical DIN rail) || by screws plate)
Network Frequency
50/60 Hz
[Ics] Rated Service Breaking Capacity
100 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 2.5 kA 690 V AC 50/60 Hz IEC 60947-2 || 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 65 kA 440 V AC 50/60 Hz IEC 60947-2
Trip Unit Technology
thermal-magneticTM-D,
Trip Unit Name
TM-D
Height
137 mm
Connection Pitch
27 mm
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz UL 489
Tightening Torque
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Breaking Capacity Code
J
9 Mm Pitches
6
Local Signalling
presence of auxiliary contacts flag green)
Number Of Slots
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
Protected Poles Description
2t
Electrical Connection
terminal nut, ON and OFF end
Net Weight
0.669 kg
[Uimp] Rated Impulse Withstand Voltage
8 kV IEC 60947-2
Control Type
toggle
Circuit Breaker Application
HACR rated
Wire Stripping Length
20 mm
Utilisation Category
category A
Line Rated Current
70-70 A
Continuous Current Rating
80 %
Breaking Capacity
100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480/277 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 250 V DC UL 489
[Ui] Rated Insulation Voltage
800 V IEC 60947-2
Mechanical Durability
15000 cycles IEC 947-1 Annex K ed 5.2
Suitability For Isolation
yes IEC 60947-2
Electrical Durability
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Poles Description
2P
Quantity Per Set
set of 1
Awg Gauge
AWG 14...AWG 8 aluminium/copper || AWG 6...AWG 3/0 aluminium/copper
Color
Gray RAL 7016)
Width
54 mm
Depth
80 mm

Specifications

Product Or Component Type
circuit breaker
Product Name
PowerPact B
Range
PowerPact
Device Application
distribution
Device Short Name
BJ 070

Environment

Ik Degree Of Protection
IK07 IEC 62262
Ambient Air Temperature For Operation
-25-70 °C
Standards
UL 489 || NEMA AB1 || EN/IEC 60947-2 || GB 14048.2 || EN/IEC 60947-5-1 || NMX J-266 || CSA C22.2 No 5
Product Certifications
UL || IEC || CCC || EAC || CSA || NOM
Ip Degree Of Protection
front cover IP40 IEC 60529
Pollution Degree
3 IEC 60947-1
Ambient Air Temperature For Storage
-50-85 °C
Quality Labels
CE
Operating Altitude
6561.68 ft (2000 m) without derating || 5000 m with derating