Schneider Electric
EMS59202
1 / 1
Descrizione
Attivo maturo
The Easergy SC150 module offers many high-performance features needed to measure and detect a fault current on the MV line. The switch controller are designed for clip in DIN rail. The measurement voltage range from 0…30 VAC VPIS and from 0…30 VAC PPACS. It include 8 digital inputs, 2 digital relay switch, and 2 RJ45 communication port. The operating temperature is -40°C to + 70°C. The storage temperature is -40°C to + 85°C. Mechanical dimensions are 140 mm in height, 45 mm in width and 140 mm in depth.- Country of Origin
- FR
- Part Number
- EMS59202
- Tariff Code
- 8537109150
- UNSPSC
- 39121521
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Specifications
- Range Of Product
- Easergy T300
- Device Short Name
- SC150
Complementary
- Communication Port Support
- 2 ETHERNET RJ45
- Measurement Voltage
- VPIS single or three phases)0-30 V AC 50/60 Hz || VDS LRM single or three phases)0-30 V AC 50/60 Hz || PPACS single or three phases)0-30 V AC 50/60 Hz
- Number Of Outputs
- switch 2 digital (relay)
- Continuous Output Current
- 8 A
- Memory Capacity
- 4 MB
- Output Voltage
- motor 12...127 V DC || motor 90...220 V AC
- Protection Type
- ANSI 50/51 : overcurrent || ANSI 50N/51N : earth fault || ANSI 67 : directional phase overcurrent || ANSI 67N : directional earth fault || ANSI 47 : negative sequence overvoltage || ANSI 27 : undervoltage || ANSI 59 : overvoltage || ANSI 59N : neutral voltage displacement || ANSI 37 : phase undercurrent
- Type Of Measurement
- voltage || frequency || current
- Product Or Component Type
- MV switch controller
- Irms Rated Making Capacity
- 15 A 4 s
- Measurement Current
- 1-1 A || 5-5 A
- Maximum Switching Voltage
- 440 V AC
- Number Of Inputs
- 8 digital IEC 61131-2 type 3
- [Us] Rated Supply Voltage
- 12...48 V DC +/- 20 %
- Communication Port Protocol
- IEC 60870-5-104
- Power Consumption In Va
- 2 VA
- Software Function
- alarm || event log || assistance in commissioning and operating the installation || security/authority verification || reports and diagrams || Operating/Status report
- Control Type
- status illuminated push-button
- Data Recording
- counter || current value before fault || sequence of event recording || event logs || demand values
- Breaking Capacity
- 2000 VA
- Analogue Input Type
- 4 current 0.01...35 A 0.001 Ohm)
- Type Of Measurement
- current class 0.5 || voltage class 0.5
- Synchronisation Time Between Inputs
- 1 ms
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1605007
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI1605007
- Eu Rohs Directive
- Compliant
Environment
- Product Certifications
- CE
- Ik Degree Of Protection
- IK07 IEC 62262
- Ambient Air Temperature For Operation
- -40-70 °C
- Height
- 140 mm
- Standards
- IEC 60255-27 || IEC 61557-12 || IEC 62586-1 || IEC 61000-4-30:class S || IEC 61850
- Electromagnetic Compatibility
- electrical fast transient/burst immunity test level 4criteria A IEC 61000-4-4 || conducted RF disturbances level 3criteria A IEC 61000-4-6 || conducted disturbance emission level 4criteria A IEC 61000-4-16 || 100 kHz damped oscillating wave level 3criteria A IEC 61000-4-12 || radiated radio-frequency electromagnetic field immunity test level 4criteria A IEC 61000-4-3 || immunity to voltage dipscriteria A IEC 61000-4-29 || electrostatic discharge level 4criteria B IEC 61000-4-2 || surge immunity test level 3criteria A IEC 61000-4-5 || magnetic field at power frequency level 5criteria B IEC 61000-4-8 || conducted and radiated emissionsclass A EN 55022
- Net Weight
- 0.515 kg
- Fixing Mode
- clip-in DIN rail)
- Ambient Air Temperature For Storage
- -40-85 °C
- Relative Humidity
- 5-95 % IEC 60068-2-30
- Ip Degree Of Protection
- body IP2X IEC 60529 || front IP4X IEC 60529
- Type Of Installation
- indoor || outdoor in cabinet
- Mechanical Robustness
- vibrations 10-2000 Hz 1 gn 10 cycles IEC 60068-2-6 || bumps 10 gn 16 ms 1000 bumps non energized IEC 60068-2-29 || shocks 10 gn 11 ms 3 pulses in operation IEC 60068-2-27
- Width
- 45 mm
- Depth
- 140 mm
- Operating Altitude
- 6561.68 ft (2000 m)
Documenti
Data Sheet
ScaricareAltre categorie
AttuatoriBlocchiCavi, tubi e manichetteCompressoriControlloGiunzioni e raccordiCilindri e PistoniElettronicaFiltriHVACPC industriali e HMIsIlluminazioneTecnica lineareMotoriAlimentatoreTrasmissione di potenzaPompe e ValvoleEnergia rinnovabileRoboticaGuarnizioni, Anelli e ConnettoriSensori e dispositivi di misuraStrumenti e AccessoriCNCAltro