1 / 2
thumbnail
thumbnail

Descrizione

Attivo maturo
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD. It provides 1NO+1NC contacts (NC mirror certified) rated up to 10A/690V AC, connection by screw clamp terminals. Clip-on front mounting, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Country of Origin
FR
Part Number
LADN113
Tariff Code
85365080
EAN
3389110820997
UNSPSC
39121522
€35.10
net
€39.00
Spedizione Gratuita!
1
Metodi di pagamento:
Migliore offerta da:
CZFornitore Automa.Net di fiducia
Disponibilità:
1 pz.
Disponibile
Aggiornato il: 01-11-2024
Garanzia:
24 mesi
Consegna stimata:
05-06 novembre a Regno Unito
Condizione:
Nuovo sigillato in fabbrica
Nuovo sigillato in fabbrica - Un articolo nuovo di zecca, inutilizzato, non aperto, non danneggiato, nella sua confezione originale sigillata dal produttore.
Informazioni sulla spedizione
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia

Environment

Ambient Air Temperature For Operation
-5-60 °C
Ip Degree Of Protection
IP20 conforming to IEC 60529
Ambient Air Temperature For Storage
-60-80 °C
Environmental Characteristic
normal environment
Protective Treatment
TH IEC 60068
Operating Altitude
9842.52 ft (3000 m)

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110807EN_V3
Sustainable Offer Status
Green Premium product
Toxic Heavy Metal Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
Reach Free Of Svhc
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
N/A
Eu Rohs Directive
Compliant

Complementary

Non-Overlap Time
1.5 ms on de-energisation no overlap between NC and NO contact || 1.5 ms on energisation no overlap between NC and NO contact
Permissible Short-Time Rating
100 A 60 °C 1 s || 120 A 60 °C 500 ms || 140 A 60 °C 100 ms
Minimum Switching Current
5 mA
Height
48 mm
Protection Type
gG fuse 10 A
Insulation Resistance
> 10 MOhm
Irms Rated Making Capacity
140 A AC conforming to IEC 60947-5-1 || 250 A DC conforming to IEC 60947-5-1
Connections - Terminals
spring terminals 2 2.5-2.5 mm²flexible without cable end || spring terminals 2 2.5-2.5 mm²rigid
Minimum Switching Voltage
17 V
Mechanical Durability
30 Mcycles
Color
dark grey
Width
26 mm
Depth
42 mm

Specifications

Product Certifications
CB || UL || CSA || CCC || EAC || UKCA
[Ith] Conventional Free Air Thermal Current
10 A (at 60 °C)
Standards
EN/IEC 60947-5-1 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.5
[Ue] Rated Operational Voltage
690 V AC 25...400 Hz
Range Compatibility
TeSys D CAD || TeSys D LC1D || TeSys Deca CAD || TeSys Deca LC1D
Product Or Component Type
auxiliary contact block
Product Name
TeSys Deca
Range
TeSys || TeSys Deca
Mounting Location
front
Pole Contact Composition
1 NO + 1 NC
[Ui] Rated Insulation Voltage
690 V IEC 60947-5-1 || 600 V UL || 600 V CSA
[Ie] Rated Operational Current
6 A at 120 V AC-15 || 1.04 A at 690 V AC-15 || 0.55 A at 125 V DC-13 || 0.1 A at 600 V DC-13
Auxiliary Contacts Operation
instantaneous
Device Short Name
LADN